{"product_id":"holzvergaserkessel-attack-slx-30-lambda-touch-30-kw","title":"Wood Gasification Boiler Attack SLX 30 Lambda Touch 30 kW","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026 Application\u003c\/h2\u003e \u003cp\u003eThe Attack SLX 30 Lambda Touch wood gasification boiler is a log wood boiler with a nominal output of 30 kW, designed for heating single-family homes, vacation homes, small businesses, and similar buildings. This model is intended for dry split logs and is suitable for heating systems that require a powerful wood heating system with modern controls, a large loading chamber, and a buffer tank.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026 Equipment\u003c\/h2\u003e \u003cp\u003eThe boiler operates on the wood gasification principle with an induced draft fan. The boiler body is made of 6 mm steel plate, the loading chamber features a dry jacket, and in the Lambda Touch version, combustion is controlled via a lambda sensor, flue gas, and boiler temperature. In this version, air supply and turbulator cleaning are automatic, and internet connectivity with remote control is possible.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe large loading chamber makes log firing easier in daily use and reduces the frequency of reloading. The controlled combustion supports stable operation, while the automatic turbulator cleaning in the Lambda Touch version increases operating convenience. At nominal output, a long burn time is possible depending on the fuel and fill level, making the boiler particularly interesting for users who want to use wood efficiently with manageable operating effort.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026 Compatibility\u003c\/h2\u003e \u003cp\u003eThe Attack SLX 30 Lambda Touch is designed for operation with a buffer tank. The manufacturer recommends a buffer volume of 2,200 liters for this output class and requires a return temperature boost to ensure the return temperature does not fall below 65 °C. For integration, a suitably sized chimney with 23 Pa draft, a thermal drain safety device or a functional cooling circuit, and installation by a qualified specialist company must be planned.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003cp\u003eThe following technical data is reliably documented for the Attack SLX 30 Lambda Touch.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eNominal Output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e30 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eSplit logs, dry, 12–20% residual moisture\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eCombustion Technology\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eWood gasification\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEfficiency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90.3%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEnergy Efficiency Class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eA+\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. Flow Temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e85 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. Operating Pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e2.5 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eLog Length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e650 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBoiler Class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDraft Requirement\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e23 Pa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue Gas Temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e175 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue Pipe Connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e150 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eLambda Sensor\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eAutomatic Cleaning\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBuffer Tank Recommended\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRecommended Buffer Volume\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e2200 l\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeight\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1472 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWidth\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e703 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDepth\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1337 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e230 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFrequency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower Consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e42 W\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eInstallation must be carried out in a suitable boiler room by a qualified specialist company. Operation requires an adequate combustion air supply, compliance with safety clearances, a suitably sized chimney, and professional integration into the heating system with return temperature boost and cooling circuit. Approximately 1 m of clearance should be available in front of the boiler, and at least 0.5 m on the sides and rear.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe boiler is intended for dry wood with 12 to 20% moisture content. The manufacturer recommends a boiler water temperature of 80 to 90 °C and points out that continuous operation below 50% output should be avoided. Installation in living spaces or hallways is not permitted.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of Delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e1 x Attack SLX 30 Lambda Touch 30 kW wood gasification boiler\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49418720969052,"sku":"ASLXL30","price":5564.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/SLXlambda-webrender.webp?v=1774512431","url":"https:\/\/nl.gemashop.de\/en\/products\/wood-gasifier-boiler-attack-slx-30-lambda-touch-30-kw","provider":"GEMA Shop","version":"1.0","type":"link"}