{"product_id":"plum-ecotouch-raumthermostat-erweiterung-gc920","title":"PLUM ecoTouch room thermostat room sensor extension GC920 for GEMA Control 920","description":"\u003ch2 data-start=\"658\" data-end=\"681\"\u003e\u003cstrong data-start=\"661\" data-end=\"681\"\u003eBrief description\u003c\/strong\u003e\u003c\/h2\u003e  \u003cp data-start=\"683\" data-end=\"953\"\u003eThe \u003cstrong data-start=\"687\" data-end=\"737\"\u003ePLUM ecoTouch room thermostat extension GC920\u003c\/strong\u003e is a functional addition for the \u003cstrong data-start=\"777\" data-end=\"815\"\u003eGEMA Control 920 heating control\u003c\/strong\u003e.  It combines a room sensor and room thermostat in one device, enabling comfortable and precise temperature control directly in the room.\u003c\/p\u003e  \u003chr data-start=\"955\" data-end=\"958\"\u003e  \u003ch2 data-start=\"960\" data-end=\"988\"\u003e\u003cstrong data-start=\"963\" data-end=\"988\"\u003eHighlights\/Advantages\u003c\/strong\u003e\u003c\/h2\u003e  \u003cp data-start=\"990\" data-end=\"1351\"\u003e⭐  \u003cstrong data-start=\"992\" data-end=\"1022\"\u003eSeamless system integration\u003c\/strong\u003e into the GEMA Control 920 via bus system\u003cbr data-start=\"1061\" data-end=\"1064\"\u003e⭐  \u003cstrong data-start=\"1066\" data-end=\"1088\"\u003e4.3″ Touch Display\u003c\/strong\u003e for intuitive and clear operation\u003cbr data-start=\"1131\" data-end=\"1134\"\u003e⭐  \u003cstrong data-start=\"1136\" data-end=\"1170\"\u003ePrecise room temperature control\u003c\/strong\u003e for increased living comfort\u003cbr data-start=\"1195\" data-end=\"1198\"\u003e⭐  \u003cstrong data-start=\"1200\" data-end=\"1248\"\u003eSupport for day and night programs\u003c\/strong\u003e depending on the controller setting\u003cbr data-start=\"1274\" data-end=\"1277\"\u003e⭐  \u003cstrong data-start=\"1279\" data-end=\"1306\"\u003eMenu lock\/Hotel mode\u003c\/strong\u003e for safe use in sensitive areas\u003c\/p\u003e  \u003chr data-start=\"1353\" data-end=\"1356\"\u003e  \u003ch2 data-start=\"1358\" data-end=\"1390\"\u003e\u003cstrong data-start=\"1361\" data-end=\"1390\"\u003eDetailed description\u003c\/strong\u003e\u003c\/h2\u003e  \u003ch3 data-start=\"1392\" data-end=\"1427\"\u003e\u003cstrong data-start=\"1396\" data-end=\"1427\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/strong\u003e\u003c\/h3\u003e  \u003cp data-start=\"1429\" data-end=\"1737\"\u003eThe \u003cstrong data-start=\"1433\" data-end=\"1483\"\u003ePLUM ecoTouch room thermostat extension GC920\u003c\/strong\u003e It is designed for use in living spaces and commercial rooms where direct room temperature control is desired. It is aimed at both end customers and professional tradespeople who are installing existing systems. \u003cstrong data-start=\"1679\" data-end=\"1707\"\u003eGEMA Control 920 Systems\u003c\/strong\u003e want to expand its functionality.\u003c\/p\u003e  \u003cp data-start=\"1739\" data-end=\"1860\"\u003eTypical areas of application include single-family and multi-family homes as well as smaller commercial units with central heating control.\u003c\/p\u003e  \u003chr data-start=\"1862\" data-end=\"1865\"\u003e  \u003ch3 data-start=\"1867\" data-end=\"1893\"\u003e\u003cstrong data-start=\"1871\" data-end=\"1893\"\u003eEveryday benefits\u003c\/strong\u003e\u003c\/h3\u003e  \u003cp data-start=\"1895\" data-end=\"2127\"\u003eThe ecoTouch thermostat allows for quick and easy adjustment of the desired temperature thanks to its in-room controls. The touchscreen provides a clear overview of all relevant information, simplifying daily use.\u003c\/p\u003e  \u003cp data-start=\"2129\" data-end=\"2270\"\u003eAccurate temperature measurement supports demand-based heating control and can thus contribute to optimizing energy consumption.\u003c\/p\u003e  \u003chr data-start=\"2272\" data-end=\"2275\"\u003e  \u003ch3 data-start=\"2277\" data-end=\"2306\"\u003e\u003cstrong data-start=\"2281\" data-end=\"2306\"\u003eTechnology \u0026amp; equipment\u003c\/strong\u003e\u003c\/h3\u003e  \u003cp data-start=\"2308\" data-end=\"2561\"\u003eThe room thermostat is connected to the GEMA Control 920 via the bus system and functions simultaneously as a room sensor and control unit. The measured temperature values ​​are continuously transmitted to the controller and incorporated into the regulation.\u003c\/p\u003e  \u003cp data-start=\"2563\" data-end=\"2697\"\u003eAdditional functions such as operating indicators, alarms or mode changes depend on the configuration of the connected controller.\u003c\/p\u003e  \u003chr data-start=\"2699\" data-end=\"2702\"\u003e  \u003ch3 data-start=\"2704\" data-end=\"2746\"\u003e\u003cstrong data-start=\"2708\" data-end=\"2746\"\u003ecompatibility \u0026amp; System integration\u003c\/strong\u003e\u003c\/h3\u003e  \u003cp data-start=\"2748\" data-end=\"2974\"\u003eThe ecoTouch panel is specifically designed for the \u003cstrong data-start=\"2788\" data-end=\"2808\"\u003eGEMA Control 920\u003c\/strong\u003e Designed for indoor use. Integration is achieved via a 4-wire bus connection. Use outside this system is not intended.\u003c\/p\u003e  \u003chr data-start=\"2976\" data-end=\"2979\"\u003e  \u003ch2 data-start=\"2981\" data-end=\"3004\"\u003e\u003cstrong data-start=\"2984\" data-end=\"3004\"\u003eTechnical data\u003c\/strong\u003e\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3006\" data-end=\"3730\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3006\" data-end=\"3024\"\u003e  \u003ctr data-start=\"3006\" data-end=\"3024\"\u003e  \u003cth data-start=\"3006\" data-end=\"3016\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3016\" data-end=\"3024\" data-col-size=\"md\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3041\" data-end=\"3730\"\u003e  \u003ctr data-start=\"3041\" data-end=\"3073\"\u003e  \u003ctd data-start=\"3041\" data-end=\"3054\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3054\" data-end=\"3073\"\u003ePLUM Sp.z o.o.\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3074\" data-end=\"3128\"\u003e  \u003ctd data-start=\"3074\" data-end=\"3083\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"3083\" data-end=\"3128\" data-col-size=\"md\"\u003eecoTouch room thermostat extension GC920\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3129\" data-end=\"3178\"\u003e  \u003ctd data-start=\"3129\" data-end=\"3142\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3142\" data-end=\"3178\"\u003eRoom thermostat\/bus extension\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3179\" data-end=\"3204\"\u003e  \u003ctd data-start=\"3179\" data-end=\"3195\" data-col-size=\"sm\"\u003eArticle number\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3195\" data-end=\"3204\"\u003ePT920\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3205\" data-end=\"3248\"\u003e  \u003ctd data-start=\"3205\" data-end=\"3215\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3215\" data-end=\"3248\"\u003e4.3″ graphic touch display\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3249\" data-end=\"3282\"\u003e  \u003ctd data-start=\"3249\" data-end=\"3271\" data-col-size=\"sm\"\u003eSupply voltage\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3271\" data-end=\"3282\"\u003e12 V DC\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3283\" data-end=\"3309\"\u003e  \u003ctd data-start=\"3283\" data-end=\"3299\" data-col-size=\"sm\"\u003epower consumption\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3299\" data-end=\"3309\"\u003e150 mA\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3310\" data-end=\"3330\"\u003e  \u003ctd data-start=\"3310\" data-end=\"3322\" data-col-size=\"sm\"\u003eProtection class\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3322\" data-end=\"3330\"\u003eIP20\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3331\" data-end=\"3363\"\u003e  \u003ctd data-start=\"3331\" data-end=\"3352\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3352\" data-end=\"3363\"\u003e0–50 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3364\" data-end=\"3393\"\u003e  \u003ctd data-start=\"3364\" data-end=\"3382\" data-col-size=\"sm\"\u003eStorage temperature\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3382\" data-end=\"3393\"\u003e0–65 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3394\" data-end=\"3430\"\u003e  \u003ctd data-start=\"3394\" data-end=\"3419\" data-col-size=\"sm\"\u003eTemperature measuring range\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3419\" data-end=\"3430\"\u003e0–50 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3431\" data-end=\"3468\"\u003e  \u003ctd data-start=\"3431\" data-end=\"3457\" data-col-size=\"sm\"\u003eTemperature control range\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3457\" data-end=\"3468\"\u003e0–35 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3469\" data-end=\"3506\"\u003e  \u003ctd data-start=\"3469\" data-end=\"3494\" data-col-size=\"sm\"\u003eAdjustable hysteresis\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3494\" data-end=\"3506\"\u003e0.2–5 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3507\" data-end=\"3565\"\u003e  \u003ctd data-start=\"3507\" data-end=\"3531\" data-col-size=\"sm\"\u003ePermissible humidity\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3531\" data-end=\"3565\"\u003e5–85% RH, non-condensing\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3566\" data-end=\"3611\"\u003e  \u003ctd data-start=\"3566\" data-end=\"3578\" data-col-size=\"sm\"\u003eConnection\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3578\" data-end=\"3611\"\u003e4-wire, max. 30 m, ≥ 0.5 mm²\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3612\" data-end=\"3651\"\u003e  \u003ctd data-start=\"3612\" data-end=\"3631\" data-col-size=\"sm\"\u003eDimensions (H × W × D)\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3631\" data-end=\"3651\"\u003e148 × 97 × 23 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3652\" data-end=\"3676\"\u003e  \u003ctd data-start=\"3652\" data-end=\"3662\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e  \u003ctd data-start=\"3662\" data-end=\"3676\" data-col-size=\"md\"\u003eapprox. 0.2 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3677\" data-end=\"3730\"\u003e  \u003ctd data-start=\"3677\" data-end=\"3686\" data-col-size=\"sm\"\u003eStandards\u003c\/td\u003e  \u003ctd data-col-size=\"md\" data-start=\"3686\" data-end=\"3730\"\u003ePN-EN 60730-1, PN-EN 60730-2-9, Class A\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"3732\" data-end=\"3735\"\u003e  \u003ch2 data-start=\"3737\" data-end=\"3756\"\u003e\u003cstrong data-start=\"3740\" data-end=\"3756\"\u003eScope of delivery\u003c\/strong\u003e\u003c\/h2\u003e  \u003cul data-start=\"3758\" data-end=\"3801\"\u003e  \u003cli data-start=\"3758\" data-end=\"3801\"\u003e  \u003cp data-start=\"3760\" data-end=\"3801\"\u003eecoTouch touch room thermostat (room panel)\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3803\" data-end=\"3806\"\u003e  \u003ch2 data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3811\" data-end=\"3845\"\u003eAssembly \u0026amp; Safety instructions\u003c\/strong\u003e\u003c\/h2\u003e  \u003cul data-start=\"3847\" data-end=\"4064\"\u003e  \u003cli data-start=\"3847\" data-end=\"3922\"\u003e  \u003cp data-start=\"3849\" data-end=\"3922\"\u003eInstallation and commissioning must be carried out exclusively by a specialist company.\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3923\" data-end=\"3997\"\u003e  \u003cp data-start=\"3925\" data-end=\"3997\"\u003ePerform installation according to the specifications of the GEMA Control 920 documentation.\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3998\" data-end=\"4064\"\u003e  \u003cp data-start=\"4000\" data-end=\"4064\"\u003eThe device is intended for use in dry indoor environments.\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"4066\" data-end=\"4069\"\u003e  \u003ch2 data-start=\"4071\" data-end=\"4081\"\u003e\u003cstrong data-start=\"4074\" data-end=\"4081\"\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e  \u003cp data-start=\"4083\" data-end=\"4235\"\u003e\u003cstrong data-start=\"4083\" data-end=\"4145\"\u003eCan the room thermostat be used without GEMA Control 920?\u003c\/strong\u003e\u003cbr data-start=\"4145\" data-end=\"4148\"\u003eNo, the device is intended exclusively as an extension for the GEMA Control 920.\u003c\/p\u003e  \u003cp data-start=\"4237\" data-end=\"4362\"\u003e\u003cstrong data-start=\"4237\" data-end=\"4290\"\u003eDoes the device measure the room temperature automatically?\u003c\/strong\u003e\u003cbr data-start=\"4290\" data-end=\"4293\"\u003eYes, the ecoTouch functions simultaneously as a room sensor and thermostat.\u003c\/p\u003e  \u003cp data-start=\"4364\" data-end=\"4515\"\u003e\u003cstrong data-start=\"4364\" data-end=\"4408\"\u003eCan time programs be set?\u003c\/strong\u003e\u003cbr data-start=\"4408\" data-end=\"4411\"\u003eTime and temperature programs are possible depending on the configuration of the connected controller.\u003c\/p\u003e  \u003cp data-start=\"4517\" data-end=\"4614\"\u003e\u003cstrong data-start=\"4517\" data-end=\"4547\"\u003eHow is the connection made?\u003c\/strong\u003e\u003cbr data-start=\"4547\" data-end=\"4550\"\u003eVia a 4-wire bus connection directly to the GEMA Control 920.\u003c\/p\u003e  \u003cp data-start=\"4616\" data-end=\"4722\"\u003e\u003cstrong data-start=\"4616\" data-end=\"4653\"\u003eIs there an app control option?\u003c\/strong\u003e\u003cbr data-start=\"4653\" data-end=\"4656\"\u003eAccording to the manufacturer, an app or Wi-Fi function is not planned.\u003c\/p\u003e  \u003cp data-start=\"4724\" data-end=\"4827\"\u003e\u003cstrong data-start=\"4724\" data-end=\"4768\"\u003eFor which rooms is the device suitable?\u003c\/strong\u003e\u003cbr data-start=\"4768\" data-end=\"4771\"\u003eFor heated indoor spaces such as living rooms, offices or utility rooms.\u003c\/p\u003e  \u003chr data-start=\"4829\" data-end=\"4832\"\u003e  \u003ch2 data-start=\"4834\" data-end=\"4846\"\u003e\u003cstrong data-start=\"4837\" data-end=\"4846\"\u003eConclusion\u003c\/strong\u003e\u003c\/h2\u003e  \u003cp data-start=\"4848\" data-end=\"5141\"\u003eThe \u003cstrong data-start=\"4852\" data-end=\"4902\"\u003ePLUM ecoTouch room thermostat extension GC920\u003c\/strong\u003e is a well-designed addition to GEMA Control 920 systems. It offers convenient operation, precise room temperature control and reliable system integration – ideal for modern heating systems in residential and commercial settings.\u003c\/p\u003e","brand":"Plum","offers":[{"title":"Default Title","offer_id":47200895598940,"sku":"PT920","price":174.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/plum-ecotouch-raumthermostat-raumfuhler-erweiterung-gc920-fur-gema-control-920-4034533.webp?v=1770693328","url":"https:\/\/nl.gemashop.de\/en\/products\/plum-ecotouch-room-thermostat-extension-gc920-1","provider":"GEMA Shop","version":"1.0","type":"link"}