{"product_id":"mpm-wood-plus-26-holzvergaserkessel-26-kw","title":"MPM Wood Plus 26 wood gasification boiler 26 kW","description":"\u003cp data-start=\"899\" data-end=\"1188\"\u003eThe \u003cstrong data-start=\"903\" data-end=\"923\"\u003eMPM Wood Plus 26\u003c\/strong\u003e This is a modern wood gasification boiler with a nominal output of 26 kW for logs. It meets the requirements of class 5 according to PN-EN 303-5 as well as the Ecodesign Directive and achieves energy efficiency class A+. Ideal for single-family homes with a buffer storage tank.\u003c\/p\u003e  \u003chr data-start=\"1190\" data-end=\"1193\"\u003e  \u003ch1 data-start=\"1195\" data-end=\"1220\"\u003eHighlights\/Advantages\u003c\/h1\u003e  \u003cp data-start=\"1222\" data-end=\"1574\"\u003e⭐ 26 kW nominal power – ideal for single-family homes and commercial units\u003cbr data-start=\"1295\" data-end=\"1298\"\u003e⭐ 5th grade \u0026amp; Ecodesign – low emissions and high environmental compatibility\u003cbr data-start=\"1374\" data-end=\"1377\"\u003e⭐ Energy efficiency class A+ (EEI 116) – economical operation\u003cbr data-start=\"1441\" data-end=\"1444\"\u003e⭐ Large loading chamber (~120 dm³) – long burning time up to approx. 6 hours\u003cbr data-start=\"1515\" data-end=\"1518\"\u003e⭐ Operation possible in an open or closed system\u003c\/p\u003e  \u003chr data-start=\"1576\" data-end=\"1579\"\u003e  \u003ch1 data-start=\"1581\" data-end=\"1610\"\u003eDetailed description\u003c\/h1\u003e  \u003ch2 data-start=\"1612\" data-end=\"1644\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1646\" data-end=\"1892\"\u003eThe MPM Wood Plus 26 is a \u003cstrong data-start=\"1675\" data-end=\"1708\"\u003elog wood gasification boiler\u003c\/strong\u003e For use in open or closed heating systems according to PN-EN 12828. It is suitable for single-family homes, smaller apartment buildings, workshops and commercial units.\u003c\/p\u003e  \u003cp data-start=\"1894\" data-end=\"2034\"\u003eThe operation is exclusively with a \u003cstrong data-start=\"1935\" data-end=\"1980\"\u003eBuffer storage tank of at least 1000 liters\u003c\/strong\u003e prescribed.\u003c\/p\u003e  \u003chr data-start=\"2036\" data-end=\"2039\"\u003e  \u003ch2 data-start=\"2041\" data-end=\"2064\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"2066\" data-end=\"2283\"\u003eThe wood gasification principle involves combustion in two separate chambers – degassing of the wood and subsequent clean afterburning in the ceramic combustion chamber.\u003c\/p\u003e  \u003cp data-start=\"2285\" data-end=\"2300\"\u003eThe result:\u003c\/p\u003e  \u003cul data-start=\"2301\" data-end=\"2415\"\u003e  \u003cli data-start=\"2301\" data-end=\"2328\"\u003e  \u003cp data-start=\"2303\" data-end=\"2328\"\u003ehigh operational reliability\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2329\" data-end=\"2352\"\u003e  \u003cp data-start=\"2331\" data-end=\"2352\"\u003estable combustion\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2353\" data-end=\"2376\"\u003e  \u003cp data-start=\"2355\" data-end=\"2376\"\u003elow emissions\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2377\" data-end=\"2415\"\u003e  \u003cp data-start=\"2379\" data-end=\"2415\"\u003elong burning time of approximately 6 hours\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2417\" data-end=\"2522\"\u003eThe large loading chamber (~120 dm³) allows for comfortable log lengths and reduces refueling intervals.\u003c\/p\u003e  \u003chr data-start=\"2524\" data-end=\"2527\"\u003e  \u003ch2 data-start=\"2529\" data-end=\"2555\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2557\" data-end=\"2631\"\u003eThe boiler is manufactured as a welded steel construction and features:\u003c\/p\u003e  \u003cul data-start=\"2633\" data-end=\"2826\"\u003e  \u003cli data-start=\"2633\" data-end=\"2657\"\u003e  \u003cp data-start=\"2635\" data-end=\"2657\"\u003emovable cast iron grate\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2658\" data-end=\"2681\"\u003e  \u003cp data-start=\"2660\" data-end=\"2681\"\u003eceramic burner\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2682\" data-end=\"2740\"\u003e  \u003cp data-start=\"2684\" data-end=\"2740\"\u003evertical heat exchanger channels with turbulence unit\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2741\" data-end=\"2767\"\u003e  \u003cp data-start=\"2743\" data-end=\"2767\"\u003emechanical train regulator\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2768\" data-end=\"2792\"\u003e  \u003cp data-start=\"2770\" data-end=\"2792\"\u003eSecondary air control\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2793\" data-end=\"2826\"\u003e  \u003cp data-start=\"2795\" data-end=\"2826\"\u003eThermometer in the upper area\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2828\" data-end=\"2944\"\u003eManual loading is done with firewood (moisture content ≤25%).\u003c\/p\u003e  \u003cp data-start=\"2946\" data-end=\"3100\"\u003eRecommended operating temperature: 60–90 °C \u003cbr\u003eMinimum return temperature: 55 °C\u003c\/p\u003e  \u003chr data-start=\"3102\" data-end=\"3105\"\u003e  \u003ch2 data-start=\"3107\" data-end=\"3130\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"3132\" data-end=\"3294\"\u003eThe MPM Wood Plus 26 meets the \u003cstrong data-start=\"3165\" data-end=\"3204\"\u003eEcodesign Regulation (EU) 2015\/1189\u003c\/strong\u003e as well as the \u003cstrong data-start=\"3215\" data-end=\"3253\"\u003e5th grade according to PN-EN 303-5:2021-09.\u003c\/strong\u003e\u003c\/p\u003e  \u003cp data-start=\"3296\" data-end=\"3484\"\u003eSeasonal energy efficiency: 79%\u003c\/p\u003e  \u003cp data-start=\"3296\" data-end=\"3484\"\u003eEnergy efficiency class: A+\u003c\/p\u003e  \u003cp data-start=\"3296\" data-end=\"3484\"\u003eEEI: 116\u003c\/p\u003e  \u003cp data-start=\"3486\" data-end=\"3516\"\u003eEmissions at rated power:\u003c\/p\u003e  \u003cul data-start=\"3517\" data-end=\"3626\"\u003e  \u003cli data-start=\"3517\" data-end=\"3533\"\u003e  \u003cp data-start=\"3519\" data-end=\"3533\"\u003ePM: 15 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3534\" data-end=\"3551\"\u003e  \u003cp data-start=\"3536\" data-end=\"3551\"\u003eOGC: 10 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3552\" data-end=\"3569\"\u003e  \u003cp data-start=\"3554\" data-end=\"3569\"\u003eCO: 398 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3570\" data-end=\"3626\"\u003e  \u003cp data-start=\"3572\" data-end=\"3626\"\u003eNOx: 142 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3628\" data-end=\"3711\"\u003eThis means the boiler meets the current requirements for modern biomass heating systems.\u003c\/p\u003e  \u003chr data-start=\"3713\" data-end=\"3716\"\u003e  \u003ch2 data-start=\"3718\" data-end=\"3757\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"3759\" data-end=\"3866\"\u003eIt can be operated in both open and closed heating systems.\u003c\/p\u003e  \u003cp data-start=\"3868\" data-end=\"4029\"\u003eMaximum operating pressure: 1.5 bar \u003c\/p\u003e  \u003cp data-start=\"3868\" data-end=\"4029\"\u003eRequired chimney draft: approx. 0.30 mbar\u003c\/p\u003e  \u003cp data-start=\"4031\" data-end=\"4133\"\u003eFor continuous operation, a return flow boost (e.g., a 3- or 4-way mixing valve) is recommended.\u003c\/p\u003e  \u003chr data-start=\"4135\" data-end=\"4138\"\u003e  \u003ch1 data-start=\"4140\" data-end=\"4158\"\u003eTechnical data\u003c\/h1\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"4160\" data-end=\"5061\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"4160\" data-end=\"4178\"\u003e  \u003ctr data-start=\"4160\" data-end=\"4178\"\u003e  \u003cth data-start=\"4160\" data-end=\"4170\" data-col-size=\"md\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"4170\" data-end=\"4178\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"4199\" data-end=\"5061\"\u003e  \u003ctr data-start=\"4199\" data-end=\"4241\"\u003e  \u003ctd data-start=\"4199\" data-end=\"4212\" data-col-size=\"md\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"4212\" data-end=\"4241\" data-col-size=\"sm\"\u003eMPM Project Marcin Nykiel\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4242\" data-end=\"4267\"\u003e  \u003ctd data-start=\"4242\" data-end=\"4251\" data-col-size=\"md\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"4251\" data-end=\"4267\" data-col-size=\"sm\"\u003eWood Plus 26\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4268\" data-end=\"4303\"\u003e  \u003ctd data-start=\"4268\" data-end=\"4281\" data-col-size=\"md\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"4281\" data-end=\"4303\" data-col-size=\"sm\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4304\" data-end=\"4332\"\u003e  \u003ctd data-start=\"4304\" data-end=\"4323\" data-col-size=\"md\"\u003eNominal heating output\u003c\/td\u003e  \u003ctd data-start=\"4323\" data-end=\"4332\" data-col-size=\"sm\"\u003e26 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4333\" data-end=\"4364\"\u003e  \u003ctd data-start=\"4333\" data-end=\"4358\" data-col-size=\"md\"\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd data-start=\"4358\" data-end=\"4364\" data-col-size=\"sm\"\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4365\" data-end=\"4402\"\u003e  \u003ctd data-start=\"4365\" data-end=\"4395\" data-col-size=\"md\"\u003eEnergy Efficiency Index (EEI)\u003c\/td\u003e  \u003ctd data-start=\"4395\" data-end=\"4402\" data-col-size=\"sm\"\u003e116\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4403\" data-end=\"4440\"\u003e  \u003ctd data-start=\"4403\" data-end=\"4432\" data-col-size=\"md\"\u003eSeasonal energy efficiency\u003c\/td\u003e  \u003ctd data-start=\"4432\" data-end=\"4440\" data-col-size=\"sm\"\u003e79%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4441\" data-end=\"4491\"\u003e  \u003ctd data-start=\"4441\" data-end=\"4456\" data-col-size=\"md\"\u003eboiler class\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4456\" data-end=\"4491\"\u003e5th class (PN-EN 303-5:2021-09)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4492\" data-end=\"4546\"\u003e  \u003ctd data-start=\"4492\" data-end=\"4536\" data-col-size=\"md\"\u003eThermal efficiency at rated power\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4536\" data-end=\"4546\"\u003e82.3%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4547\" data-end=\"4570\"\u003e  \u003ctd data-start=\"4547\" data-end=\"4560\" data-col-size=\"md\"\u003eheating surface\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4560\" data-end=\"4570\"\u003e2.9 m²\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4571\" data-end=\"4597\"\u003e  \u003ctd data-start=\"4571\" data-end=\"4587\" data-col-size=\"md\"\u003eWater volume\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4587\" data-end=\"4597\"\u003e94 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4598\" data-end=\"4633\"\u003e  \u003ctd data-start=\"4598\" data-end=\"4618\" data-col-size=\"md\"\u003eLoading chamber volume\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4618\" data-end=\"4633\"\u003eapprox. 120 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4634\" data-end=\"4658\"\u003e  \u003ctd data-start=\"4634\" data-end=\"4647\" data-col-size=\"md\"\u003eBurning time\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4647\" data-end=\"4658\"\u003eapprox. 6 h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4659\" data-end=\"4691\"\u003e  \u003ctd data-start=\"4659\" data-end=\"4681\" data-col-size=\"md\"\u003eFuel consumption\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4681\" data-end=\"4691\"\u003e7 kg\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4692\" data-end=\"4724\"\u003e  \u003ctd data-start=\"4692\" data-end=\"4710\" data-col-size=\"md\"\u003eExhaust gas temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4710\" data-end=\"4724\"\u003e125–140 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4725\" data-end=\"4754\"\u003e  \u003ctd data-start=\"4725\" data-end=\"4744\" data-col-size=\"md\"\u003eExhaust gas mass flow\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4744\" data-end=\"4754\"\u003e15 g\/s\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4755\" data-end=\"4787\"\u003e  \u003ctd data-start=\"4755\" data-end=\"4776\" data-col-size=\"md\"\u003eMax. operating pressure\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4776\" data-end=\"4787\"\u003e1.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4788\" data-end=\"4821\"\u003e  \u003ctd data-start=\"4788\" data-end=\"4809\" data-col-size=\"md\"\u003eOperating temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4809\" data-end=\"4821\"\u003e60–90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4822\" data-end=\"4861\"\u003e  \u003ctd data-start=\"4822\" data-end=\"4852\" data-col-size=\"md\"\u003eMinimum return temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4852\" data-end=\"4861\"\u003e55 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4862\" data-end=\"4880\"\u003e  \u003ctd data-start=\"4862\" data-end=\"4869\" data-col-size=\"md\"\u003eHeight\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4869\" data-end=\"4880\"\u003e1183 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4881\" data-end=\"4908\"\u003e  \u003ctd data-start=\"4881\" data-end=\"4898\" data-col-size=\"md\"\u003eWide cases\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4898\" data-end=\"4908\"\u003e600 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4909\" data-end=\"4934\"\u003e  \u003ctd data-start=\"4909\" data-end=\"4924\" data-col-size=\"md\"\u003eTotal width\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4924\" data-end=\"4934\"\u003e655 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4935\" data-end=\"4960\"\u003e  \u003ctd data-start=\"4935\" data-end=\"4949\" data-col-size=\"md\"\u003eTotal length\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4949\" data-end=\"4960\"\u003e1220 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4961\" data-end=\"4985\"\u003e  \u003ctd data-start=\"4961\" data-end=\"4971\" data-col-size=\"md\"\u003eWeight\u003c\/td\u003e  \u003ctd data-start=\"4971\" data-end=\"4985\" data-col-size=\"sm\"\u003eapprox. 450 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4986\" data-end=\"5021\"\u003e  \u003ctd data-start=\"4986\" data-end=\"5012\" data-col-size=\"md\"\u003eConnection flow\/return\u003c\/td\u003e  \u003ctd data-start=\"5012\" data-end=\"5021\" data-col-size=\"sm\"\u003e40 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5022\" data-end=\"5061\"\u003e  \u003ctd data-start=\"5022\" data-end=\"5047\" data-col-size=\"md\"\u003eMinimum buffer storage\u003c\/td\u003e  \u003ctd data-start=\"5047\" data-end=\"5061\" data-col-size=\"sm\"\u003e1000 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"5063\" data-end=\"5066\"\u003e  \u003ch1 data-start=\"5068\" data-end=\"5084\"\u003eScope of delivery\u003c\/h1\u003e  \u003cul data-start=\"5086\" data-end=\"5188\"\u003e  \u003cli data-start=\"5086\" data-end=\"5125\"\u003e  \u003cp data-start=\"5088\" data-end=\"5125\"\u003eMPM Wood Plus 26 wood gasification boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5126\" data-end=\"5149\"\u003e  \u003cp data-start=\"5128\" data-end=\"5149\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5150\" data-end=\"5170\"\u003e  \u003cp data-start=\"5152\" data-end=\"5170\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5171\" data-end=\"5188\"\u003e  \u003cp data-start=\"5173\" data-end=\"5188\"\u003eWarranty card\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"5190\" data-end=\"5193\"\u003e  \u003ch1 data-start=\"5195\" data-end=\"5219\"\u003eAccessories\/Recommendation\u003c\/h1\u003e  \u003cp data-start=\"5221\" data-end=\"5263\"\u003eFor optimal operation, we recommend:\u003c\/p\u003e  \u003cul data-start=\"5265\" data-end=\"5473\"\u003e  \u003cli data-start=\"5265\" data-end=\"5296\"\u003e  \u003cp data-start=\"5267\" data-end=\"5296\"\u003eBuffer storage tank ≥ 1000 liters\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5297\" data-end=\"5349\"\u003e  \u003cp data-start=\"5299\" data-end=\"5349\"\u003eThermal mixing valve (return temperature increase 55 °C)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5350\" data-end=\"5388\"\u003e  \u003cp data-start=\"5352\" data-end=\"5388\"\u003eSafety group with DBV-1 valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5389\" data-end=\"5425\"\u003e  \u003cp data-start=\"5391\" data-end=\"5425\"\u003eDraft regulator for the chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5426\" data-end=\"5473\"\u003e  \u003cp data-start=\"5428\" data-end=\"5473\"\u003eSuitable stratified storage tank for domestic hot water\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5475\" data-end=\"5598\"\u003eYou can find suitable products in the section \u003cstrong data-start=\"5515\" data-end=\"5533\"\u003eBuffer storage\u003c\/strong\u003e, \u003cstrong data-start=\"5535\" data-end=\"5557\"\u003eSecurity groups\u003c\/strong\u003e and \u003cstrong data-start=\"5562\" data-end=\"5581\"\u003eHeating accessories\u003c\/strong\u003e on gemashop.de.\u003c\/p\u003e  \u003chr data-start=\"5600\" data-end=\"5603\"\u003e  \u003ch1 data-start=\"5605\" data-end=\"5639\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h1\u003e  \u003cp data-start=\"5641\" data-end=\"5728\"\u003eInstallation must be carried out exclusively by a qualified specialist company.\u003c\/p\u003e  \u003cp data-start=\"5730\" data-end=\"5830\"\u003eThe boiler must be operated with a buffer storage tank.\u003c\/p\u003e  \u003cp data-start=\"5832\" data-end=\"5982\"\u003eThe return temperature must not fall below 55 °C, otherwise corrosion damage and loss of warranty are likely.\u003c\/p\u003e  \u003chr data-start=\"5984\" data-end=\"5987\"\u003e  \u003ch1 data-start=\"5989\" data-end=\"5996\"\u003eFAQ\u003c\/h1\u003e  \u003cp data-start=\"5998\" data-end=\"6136\"\u003e\u003cstrong data-start=\"5998\" data-end=\"6071\"\u003e1. What type of fuel can the MPM Wood Plus 26 be operated with?\u003c\/strong\u003e\u003cbr data-start=\"6071\" data-end=\"6074\"\u003eUsing firewood (hardwood) with a moisture content ≤25%.\u003c\/p\u003e  \u003cp data-start=\"6138\" data-end=\"6230\"\u003e\u003cstrong data-start=\"6138\" data-end=\"6181\"\u003e2. Is a buffer storage tank required?\u003c\/strong\u003e\u003cbr data-start=\"6181\" data-end=\"6184\"\u003eYes, at least 1000 liters are required.\u003c\/p\u003e  \u003cp data-start=\"6232\" data-end=\"6310\"\u003e\u003cstrong data-start=\"6232\" data-end=\"6282\"\u003e3. What efficiency class does the boiler achieve?\u003c\/strong\u003e\u003cbr data-start=\"6282\" data-end=\"6285\"\u003eA+ with an EEI of 116.\u003c\/p\u003e  \u003cp data-start=\"6312\" data-end=\"6443\"\u003e\u003cstrong data-start=\"6312\" data-end=\"6367\"\u003e4. Is operation in a closed system permitted?\u003c\/strong\u003e\u003cbr data-start=\"6367\" data-end=\"6370\"\u003eYes, if professionally installed with a safety valve and thermal insulation.\u003c\/p\u003e  \u003cp data-start=\"6445\" data-end=\"6523\"\u003e\u003cstrong data-start=\"6445\" data-end=\"6503\"\u003e5. What is the minimum return temperature required?\u003c\/strong\u003e\u003cbr data-start=\"6503\" data-end=\"6506\"\u003eAt least 55 °C.\u003c\/p\u003e  \u003cp data-start=\"6525\" data-end=\"6629\"\u003e\u003cstrong data-start=\"6525\" data-end=\"6574\"\u003e6. What emission class does the boiler meet?\u003c\/strong\u003e\u003cbr data-start=\"6574\" data-end=\"6577\"\u003eClass 5 according to PN-EN 303-5:2021-09 and Ecodesign.\u003c\/p\u003e  \u003chr data-start=\"6631\" data-end=\"6634\"\u003e  \u003ch1 data-start=\"6636\" data-end=\"6645\"\u003eConclusion\u003c\/h1\u003e  \u003cp data-start=\"6647\" data-end=\"6926\"\u003eThe \u003cstrong data-start=\"6651\" data-end=\"6690\"\u003eMPM Wood Plus 26 wood gasification boiler\u003c\/strong\u003e This is a technically sophisticated, efficient, and ecodesign-compliant solution for modern log-fired heating systems with buffer storage. Ideal for discerning users who value efficiency, emission levels, and durable construction.\u003c\/p\u003e  \u003cp data-start=\"6928\" data-end=\"6974\"\u003eOrder now and heat efficiently with wood.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":54128565092700,"sku":"MPMWP26","price":3317.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-wood-plus-26-kw-holzvergaserkessel-a-klasse-5-o178-2082115.webp?v=1770692503","url":"https:\/\/nl.gemashop.de\/en\/products\/mpm-wood-plus-26-wood-gasification-boiler-26-kw","provider":"GEMA Shop","version":"1.0","type":"link"}