{"title":"Fixed fuel boiler up to 40 kW","description":"","products":[{"product_id":"atmos-kc35s-kohlekessel","title":"ATMOS KC 35 S coal gasifier 35 kW - boiler for brown coal briquettes","description":"\u003ch2 data-start=\"3497\" data-end=\"3535\"\u003eATMOS KC 35 S – coal gasifier 35 kW\u003c\/h2\u003e  \u003ch3 data-start=\"3537\" data-end=\"3562\"\u003eProduct description\u003c\/h3\u003e  \u003cp data-start=\"3563\" data-end=\"3815\"\u003eThe ATMOS KC 35 S is a high-performance gasification boiler for larger residential and commercial buildings. Its robust steel construction, ceramic combustion chamber, and optimized flue gas routing ensure economical operation with high operational reliability.\u003c\/p\u003e  \u003ch3 data-start=\"3817\" data-end=\"3833\"\u003eHighlights\u003c\/h3\u003e  \u003cul data-start=\"3834\" data-end=\"3981\"\u003e  \u003cli data-start=\"3834\" data-end=\"3856\"\u003e  \u003cp data-start=\"3836\" data-end=\"3856\"\u003e35 kW heating output\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3857\" data-end=\"3884\"\u003e  \u003cp data-start=\"3859\" data-end=\"3884\"\u003eEfficiency up to 90.3%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3885\" data-end=\"3922\"\u003e  \u003cp data-start=\"3887\" data-end=\"3922\"\u003eSuitable for large buffer storage tanks\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3923\" data-end=\"3962\"\u003e  \u003cp data-start=\"3925\" data-end=\"3962\"\u003eExhaust brake\/turbulator as standard\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3963\" data-end=\"3981\"\u003e  \u003cp data-start=\"3965\" data-end=\"3981\"\u003eBImSchV Level II\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3 data-start=\"3983\" data-end=\"4006\"\u003eAreas of application\u003c\/h3\u003e  \u003cp data-start=\"4007\" data-end=\"4026\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4024\"\u003eSuitable for:\u003c\/strong\u003e\u003c\/p\u003e  \u003cul data-start=\"4027\" data-end=\"4108\"\u003e  \u003cli data-start=\"4027\" data-end=\"4049\"\u003e  \u003cp data-start=\"4029\" data-end=\"4049\"\u003eApartment buildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4050\" data-end=\"4081\"\u003e  \u003cp data-start=\"4052\" data-end=\"4081\"\u003eAgricultural buildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4082\" data-end=\"4108\"\u003e  \u003cp data-start=\"4084\" data-end=\"4108\"\u003eWorkshops and halls\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"4110\" data-end=\"4135\"\u003e\u003cstrong data-start=\"4110\" data-end=\"4133\"\u003eNot suitable for:\u003c\/strong\u003e\u003c\/p\u003e  \u003cul data-start=\"4136\" data-end=\"4219\"\u003e  \u003cli data-start=\"4136\" data-end=\"4178\"\u003e  \u003cp data-start=\"4138\" data-end=\"4178\"\u003eLow-load operation without buffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4179\" data-end=\"4219\"\u003e  \u003cp data-start=\"4181\" data-end=\"4219\"\u003eMoisture or unsuitable fuels\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3 data-start=\"4221\" data-end=\"4252\"\u003eTechnical specifications (excerpt)\u003c\/h3\u003e  \u003cul data-start=\"4253\" data-end=\"4498\"\u003e  \u003cli data-start=\"4253\" data-end=\"4276\"\u003e  \u003cp data-start=\"4255\" data-end=\"4276\"\u003eRated power: 35 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4277\" data-end=\"4301\"\u003e  \u003cp data-start=\"4279\" data-end=\"4301\"\u003eEfficiency: 90.3%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4302\" data-end=\"4330\"\u003e  \u003cp data-start=\"4304\" data-end=\"4330\"\u003eFuel volume: 100 l\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4331\" data-end=\"4369\"\u003e  \u003cp data-start=\"4333\" data-end=\"4369\"\u003eFlue pipe connection: Ø 150\/152 mm\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4370\" data-end=\"4411\"\u003e  \u003cp data-start=\"4372\" data-end=\"4411\"\u003eDimensions (H × W × D): 1435 × 675 × 758 mm\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4412\" data-end=\"4431\"\u003e  \u003cp data-start=\"4414\" data-end=\"4431\"\u003eWeight: 377 kg\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4432\" data-end=\"4454\"\u003e  \u003cp data-start=\"4434\" data-end=\"4454\"\u003eWater capacity: 68 l\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4455\" data-end=\"4480\"\u003e  \u003cp data-start=\"4457\" data-end=\"4480\"\u003eChimney draft: 24 Pa\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4481\" data-end=\"4498\"\u003e  \u003cp data-start=\"4483\" data-end=\"4498\"\u003eBoiler class: 5\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3 data-start=\"4500\" data-end=\"4518\"\u003eScope of delivery\u003c\/h3\u003e  \u003cul data-start=\"4519\" data-end=\"4637\"\u003e  \u003cli data-start=\"4519\" data-end=\"4536\"\u003e  \u003cp data-start=\"4521\" data-end=\"4536\"\u003eATMOS KC 35 S\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4537\" data-end=\"4568\"\u003e  \u003cp data-start=\"4539\" data-end=\"4568\"\u003eExhaust fan (Ø 175 mm)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4569\" data-end=\"4589\"\u003e  \u003cp data-start=\"4571\" data-end=\"4589\"\u003eTrain regulator FR 124\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4590\" data-end=\"4615\"\u003e  \u003cp data-start=\"4592\" data-end=\"4615\"\u003eAshtray \u0026amp; Accesories\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4616\" data-end=\"4637\"\u003e  \u003cp data-start=\"4618\" data-end=\"4637\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3 data-start=\"4639\" data-end=\"4650\"\u003eConclusion\u003c\/h3\u003e  \u003cp data-start=\"4651\" data-end=\"4833\"\u003eThe KC 35 S is ideal for high heat demands and impresses with its efficiency, stability and compliance with standards.\u003c\/p\u003e  \u003cp data-start=\"900\" data-end=\"1109\"\u003e👉  \u003cstrong data-start=\"903\" data-end=\"950\"\u003eOrder commissioning now, along with the commissioning!\u003c\/strong\u003e\u003cbr data-start=\"950\" data-end=\"953\"\u003eWith the \u0026quot;Commissioning by ATMOS\u0026quot; service, you ensure that your boiler is optimally set up and that all technical requirements are met.\u003c\/p\u003e  \u003cp data-start=\"1111\" data-end=\"1305\"\u003eFurther information on the process, requirements and services can be found in our article on \u003cstrong data-start=\"1209\" data-end=\"1304\"\u003e[\u003ca href=\"https:\/\/gemashop.de\/products\/atmos-inbetriebnahme\" title=\"Atmos Inbetriebnahme\" rel=\"noopener\" target=\"_blank\"\u003eATMOS commissioning\u003c\/a\u003e]\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Atmos","offers":[{"title":"Default Title","offer_id":49417084830044,"sku":"01.12.35","price":4759.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/atmos-kc-35-s-kohlevergaser-35-kw-heizkessel-fur-braunkohlebriketts-8173353.webp?v=1770692665"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/collections\/festbrennstoffkessel-bis-40-kw-7409309.webp?v=1770692154","url":"https:\/\/nl.gemashop.de\/en\/collections\/bis-40-kw.oembed","provider":"GEMA Shop","version":"1.0","type":"link"}