{"title":"Wood carburetor up to 20 kW","description":"","products":[{"product_id":"attack-slx-20-profi-holzvergaser-20kw","title":"Wood gasifier 20 kW ATTACK SLX 20 Profi","description":"\u003cp data-start=\"1117\" data-end=\"1415\"\u003eThe \u003cstrong data-start=\"1121\" data-end=\"1144\"\u003eATTACK SLX 20 Professional\u003c\/strong\u003e is a compact \u003cstrong data-start=\"1163\" data-end=\"1190\"\u003ewood gasification boiler\u003c\/strong\u003e For firewood with practical performance for single-family homes and smaller buildings. The wood gasification principle ensures efficient and clean combustion. Ideal in combination with a buffer tank and return temperature boost.\u003c\/p\u003e  \u003ch3 data-start=\"1417\" data-end=\"1442\"\u003eHighlights\/Advantages\u003c\/h3\u003e  \u003cp data-start=\"1443\" data-end=\"1755\"\u003e⭐ Wood gasification technology for efficient log combustion\u003cbr data-start=\"1502\" data-end=\"1505\"\u003e⭐ Stable heating operation with suitable hydraulics (buffer\/return temperature boost)\u003cbr data-start=\"1577\" data-end=\"1580\"\u003e⭐ Suitable for single-family homes, holiday homes and renovations\u003cbr data-start=\"1624\" data-end=\"1627\"\u003e⭐ Easy-to-maintain design (regular cleaning recommended)\u003cbr data-start=\"1695\" data-end=\"1698\"\u003e⭐ Certified boiler series (EN 303-5 depending on the version)\u003c\/p\u003e  \u003ch2 data-start=\"1757\" data-end=\"1785\"\u003eDetailed description\u003c\/h2\u003e  \u003ch3 data-start=\"1787\" data-end=\"1818\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h3\u003e  \u003cp data-start=\"1819\" data-end=\"2054\"\u003eThe SLX 20 Profi is suitable for \u003cstrong data-start=\"1852\" data-end=\"1873\"\u003eSingle-family homes\u003c\/strong\u003e,  Holiday homes and smaller businesses with moderate heating requirements. It is particularly useful if reliable heating with firewood is planned and a buffer storage tank is in place.\u003c\/p\u003e  \u003ch3 data-start=\"2056\" data-end=\"2078\"\u003eEveryday benefits\u003c\/h3\u003e  \u003cp data-start=\"2079\" data-end=\"2242\"\u003eWood is used efficiently in the wood gasification principle: even combustion, good heat yield and a heating operation that runs stably with correct system hydraulics.\u003c\/p\u003e  \u003ch3 data-start=\"2244\" data-end=\"2269\"\u003eTechnology \u0026amp; equipment\u003c\/h3\u003e  \u003cp data-start=\"2270\" data-end=\"2423\"\u003eThe boiler is designed as a log-fired wood gasifier. \u003cstrong data-start=\"2316\" data-end=\"2331\"\u003elogs\u003c\/strong\u003e Designed for robust, practical use. The professional version is designed for heavy-duty, practical operation.\u003c\/p\u003e  \u003ch3 data-start=\"2425\" data-end=\"2447\"\u003eEfficiency \u0026amp; Environment\u003c\/h3\u003e  \u003cp data-start=\"2448\" data-end=\"2607\"\u003eThe combustion process is designed for efficient energy yield. The specific design and system configuration are crucial for compliance with funding\/standard requirements.\u003c\/p\u003e  \u003ch3 data-start=\"2609\" data-end=\"2647\"\u003ecompatibility \u0026amp; System integration\u003c\/h3\u003e  \u003cp data-start=\"2648\" data-end=\"2677\"\u003eRecommended in combination with:\u003c\/p\u003e  \u003cul data-start=\"2678\" data-end=\"2869\"\u003e  \u003cli data-start=\"2678\" data-end=\"2736\"\u003e  \u003cp data-start=\"2680\" data-end=\"2736\"\u003eBuffer storage (decoupling power\/fuel operation)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2737\" data-end=\"2787\"\u003e  \u003cp data-start=\"2739\" data-end=\"2787\"\u003eReturn temperature boost (boiler protection\/temperature level)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2788\" data-end=\"2869\"\u003e  \u003cp data-start=\"2790\" data-end=\"2869\"\u003eSafety group, expansion vessel, thermal relief valve (system-side)\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch2 data-start=\"2871\" data-end=\"2890\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"2891\" data-end=\"3292\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"2891\" data-end=\"2909\"\u003e  \u003ctr data-start=\"2891\" data-end=\"2909\"\u003e  \u003cth data-start=\"2891\" data-end=\"2901\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"2901\" data-end=\"2909\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"2920\" data-end=\"3292\"\u003e  \u003ctr data-start=\"2920\" data-end=\"2943\"\u003e  \u003ctd data-start=\"2920\" data-end=\"2933\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2933\" data-end=\"2943\"\u003eATTACK\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2944\" data-end=\"2969\"\u003e  \u003ctd data-start=\"2944\" data-end=\"2953\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2953\" data-end=\"2969\"\u003eSLX 20 Professional\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2970\" data-end=\"3010\"\u003e  \u003ctd data-start=\"2970\" data-end=\"2983\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2983\" data-end=\"3010\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3011\" data-end=\"3064\"\u003e  \u003ctd data-start=\"3011\" data-end=\"3036\" data-col-size=\"sm\"\u003ePreferred fuel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3036\" data-end=\"3064\"\u003eLogs (firewood)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3065\" data-end=\"3118\"\u003e  \u003ctd data-start=\"3065\" data-end=\"3107\" data-col-size=\"sm\"\u003eUseful heat output at nominal heat output\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3107\" data-end=\"3118\"\u003e19.7 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3119\" data-end=\"3163\"\u003e  \u003ctd data-start=\"3119\" data-end=\"3153\" data-col-size=\"sm\"\u003eUseful heat output at [30%\/50%]\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3153\" data-end=\"3163\"\u003e9.7 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3164\" data-end=\"3215\"\u003e  \u003ctd data-start=\"3164\" data-end=\"3205\" data-col-size=\"sm\"\u003eefficiency at nominal heat output\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3205\" data-end=\"3215\"\u003e81.9%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3216\" data-end=\"3259\"\u003e  \u003ctd data-start=\"3216\" data-end=\"3249\" data-col-size=\"sm\"\u003eEfficiency at [30%\/50%]\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3249\" data-end=\"3259\"\u003e82.4%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3260\" data-end=\"3292\"\u003e  \u003ctd data-start=\"3260\" data-end=\"3283\" data-col-size=\"sm\"\u003eRecommended chimney draft\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3283\" data-end=\"3292\"\u003e23 Pa\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003ch2 data-start=\"3294\" data-end=\"3309\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"3310\" data-end=\"3398\"\u003e  \u003cli data-start=\"3310\" data-end=\"3357\"\u003e  \u003cp data-start=\"3312\" data-end=\"3357\"\u003eWood gasification boiler (device as per article)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3358\" data-end=\"3379\"\u003e  \u003cp data-start=\"3360\" data-end=\"3379\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3380\" data-end=\"3398\"\u003e  \u003cp data-start=\"3382\" data-end=\"3398\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch2 data-start=\"3400\" data-end=\"3439\"\u003eAccessories\/Recommendation (Cross-selling)\u003c\/h2\u003e  \u003cp data-start=\"3440\" data-end=\"3465\"\u003eSuitable (depending on the system):\u003c\/p\u003e  \u003cul data-start=\"3466\" data-end=\"3743\"\u003e  \u003cli data-start=\"3466\" data-end=\"3510\"\u003e  \u003cp data-start=\"3468\" data-end=\"3510\"\u003eBuffer storage (Category: Buffer storage)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3511\" data-end=\"3586\"\u003e  \u003cp data-start=\"3513\" data-end=\"3586\"\u003eReturn flow booster\/Laddomat\/mixing circuit (Category: Hydraulics\/Accessories)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3587\" data-end=\"3684\"\u003e  \u003cp data-start=\"3589\" data-end=\"3684\"\u003eSafety group, expansion vessel, thermal relief valve (Category: Safety technology)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3685\" data-end=\"3743\"\u003e  \u003cp data-start=\"3687\" data-end=\"3743\"\u003eFlue pipe\/connection accessories (Category: Exhaust\/Connection)\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch2 data-start=\"3745\" data-end=\"3778\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"3779\" data-end=\"4051\"\u003eInstallation\/commissioning must be carried out by a qualified professional. For safe operation, local regulations, suitable hydraulics (buffer tank\/return temperature boost) and safety components must be provided on the system side.Regular cleaning and maintenance according to instructions.\u003c\/p\u003e  \u003ch2 data-start=\"4053\" data-end=\"4059\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"4060\" data-end=\"4154\"\u003e\u003cstrong data-start=\"4060\" data-end=\"4099\"\u003e1) Which fuel is suitable?\u003c\/strong\u003e\u003cbr data-start=\"4099\" data-end=\"4102\"\u003eLogs (firewood) as the preferred fuel.\u003c\/p\u003e  \u003cp data-start=\"4156\" data-end=\"4276\"\u003e\u003cstrong data-start=\"4156\" data-end=\"4192\"\u003e2) Is a buffer storage tank necessary?\u003c\/strong\u003e\u003cbr data-start=\"4192\" data-end=\"4195\"\u003eFor wood gasification operation, a buffer storage tank is strongly recommended in practice.\u003c\/p\u003e  \u003cp data-start=\"4278\" data-end=\"4342\"\u003e\u003cstrong data-start=\"4278\" data-end=\"4318\"\u003e3) What chimney draft should be planned?\u003c\/strong\u003e\u003cbr data-start=\"4318\" data-end=\"4321\"\u003eRecommended: \u003cstrong data-start=\"4332\" data-end=\"4341\"\u003e23 Pa\u003c\/strong\u003e.\u003c\/p\u003e  \u003cp data-start=\"4344\" data-end=\"4443\"\u003e\u003cstrong data-start=\"4344\" data-end=\"4382\"\u003e4) For which buildings is 20 kW suitable?\u003c\/strong\u003e\u003cbr data-start=\"4382\" data-end=\"4385\"\u003eTypical single-family homes\/smaller properties – design based on heat demand.\u003c\/p\u003e  \u003cp data-start=\"4445\" data-end=\"4537\"\u003e\u003cstrong data-start=\"4445\" data-end=\"4478\"\u003e5) What does wood gasifier mean?\u003c\/strong\u003e\u003cbr data-start=\"4478\" data-end=\"4481\"\u003eWood is gasified; the wood gas is burned efficiently.\u003c\/p\u003e  \u003cp data-start=\"4539\" data-end=\"4603\"\u003e\u003cstrong data-start=\"4539\" data-end=\"4565\"\u003e6) Who is allowed to assemble it?\u003c\/strong\u003e\u003cbr data-start=\"4565\" data-end=\"4568\"\u003eOnly a qualified specialist company.\u003c\/p\u003e  \u003ch2 data-start=\"4605\" data-end=\"4613\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"4614\" data-end=\"4773\"\u003eThe \u003cstrong data-start=\"4618\" data-end=\"4641\"\u003eATTACK SLX 20 Professional\u003c\/strong\u003e is a solid choice for efficient heating with firewood in single-family homes – ideal with buffer storage and clean system hydraulics.\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49418190225756,"sku":"ASLXP20","price":3820.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/SLXprofi-webrender.webp?v=1774512395"},{"product_id":"attack-slx-20-lambda-holzvergaser-20-kw","title":"Wood gasifier 20 kW ATTACK SLX 20 Lambda","description":"\u003cp data-start=\"327\" data-end=\"704\"\u003eThe \u003cstrong data-start=\"331\" data-end=\"355\"\u003eATTACK SLX 20 LAMBDA\u003c\/strong\u003e This is a modern wood gasification boiler with a nominal output of 20 kW and integrated lambda control for particularly precise and low-emission combustion of logs. It is ideally suited for single-family and two-family homes, both new builds and renovations. Thanks to automatic air control, it offers high user-friendliness and optimized fuel utilization.\u003c\/p\u003e  \u003chr data-start=\"706\" data-end=\"709\"\u003e  \u003ch2 data-start=\"711\" data-end=\"735\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"737\" data-end=\"1062\"\u003e⭐  \u003cstrong data-start=\"739\" data-end=\"761\"\u003e20 kW nominal power\u003c\/strong\u003e – ideal for single-family homes\u003cbr data-start=\"791\" data-end=\"794\"\u003e⭐  \u003cstrong data-start=\"796\" data-end=\"823\"\u003eLambda sensor integrated\u003c\/strong\u003e – automatic and precise combustion control\u003cbr data-start=\"871\" data-end=\"874\"\u003e⭐  \u003cstrong data-start=\"876\" data-end=\"903\"\u003eEfficiency up to 90.2%\u003c\/strong\u003e – efficient energy use\u003cbr data-start=\"934\" data-end=\"937\"\u003e⭐  \u003cstrong data-start=\"939\" data-end=\"974\"\u003eCertified according to EN 303-5:2012\u003c\/strong\u003e – tested emission values\u003cbr data-start=\"1000\" data-end=\"1003\"\u003e⭐  \u003cstrong data-start=\"1005\" data-end=\"1041\"\u003eTurbulators with cleaning lever\u003c\/strong\u003e – easy maintenance\u003c\/p\u003e  \u003chr data-start=\"1064\" data-end=\"1067\"\u003e  \u003ch1 data-start=\"1069\" data-end=\"1110\"\u003eATTACK SLX 20 LAMBDA wood gasifier 20 kW\u003c\/h1\u003e  \u003ch2 data-start=\"1112\" data-end=\"1142\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1144\" data-end=\"1306\"\u003eThe ATTACK SLX 20 LAMBDA is a \u003cstrong data-start=\"1177\" data-end=\"1226\"\u003eHot water boiler for solid fuels (wood)\u003c\/strong\u003e with automatic air control via lambda sensor. It is particularly suitable for:\u003c\/p\u003e  \u003cul data-start=\"1308\" data-end=\"1421\"\u003e  \u003cli data-start=\"1308\" data-end=\"1329\"\u003e  \u003cp data-start=\"1310\" data-end=\"1329\"\u003eSingle-family homes\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1330\" data-end=\"1352\"\u003e  \u003cp data-start=\"1332\" data-end=\"1352\"\u003eTwo-family houses\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1353\" data-end=\"1386\"\u003e  \u003cp data-start=\"1355\" data-end=\"1386\"\u003eenergy-efficient renovations\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1387\" data-end=\"1421\"\u003e  \u003cp data-start=\"1389\" data-end=\"1421\"\u003eHeating systems with buffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"1423\" data-end=\"1497\"\u003ePreferred fuels are \u003cstrong data-start=\"1451\" data-end=\"1496\"\u003eLogs with a moisture content ≤ 25%\u003c\/strong\u003e.\u003c\/p\u003e  \u003chr data-start=\"1499\" data-end=\"1502\"\u003e  \u003ch2 data-start=\"1504\" data-end=\"1525\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1527\" data-end=\"1662\"\u003eThe integrated lambda control continuously measures the residual oxygen in the exhaust gas and automatically adjusts the air supply. This results in:\u003c\/p\u003e  \u003cul data-start=\"1664\" data-end=\"1788\"\u003e  \u003cli data-start=\"1664\" data-end=\"1698\"\u003e  \u003cp data-start=\"1666\" data-end=\"1698\"\u003eoptimal combustion quality\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1699\" data-end=\"1734\"\u003e  \u003cp data-start=\"1701\" data-end=\"1734\"\u003ereduced fuel consumption\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1735\" data-end=\"1763\"\u003e  \u003cp data-start=\"1737\" data-end=\"1763\"\u003estable power output\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1764\" data-end=\"1788\"\u003e  \u003cp data-start=\"1766\" data-end=\"1788\"\u003elow emissions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"1790\" data-end=\"1906\"\u003eThe automatic control ensures high comfort and consistent efficiency – even with varying wood quality.\u003c\/p\u003e  \u003chr data-start=\"1908\" data-end=\"1911\"\u003e  \u003ch2 data-start=\"1913\" data-end=\"1937\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cul data-start=\"1939\" data-end=\"2295\"\u003e  \u003cli data-start=\"1939\" data-end=\"1983\"\u003e  \u003cp data-start=\"1941\" data-end=\"1983\"\u003eBoiler type: Wood gasification hot water boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1984\" data-end=\"2003\"\u003e  \u003cp data-start=\"1986\" data-end=\"2003\"\u003ePower: 20 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2004\" data-end=\"2051\"\u003e  \u003cp data-start=\"2006\" data-end=\"2051\"\u003eLambda sensor for automatic air control\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2052\" data-end=\"2090\"\u003e  \u003cp data-start=\"2054\" data-end=\"2090\"\u003eFan-assisted combustion\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2091\" data-end=\"2128\"\u003e  \u003cp data-start=\"2093\" data-end=\"2128\"\u003eTurbulators in the tube heat exchanger\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2129\" data-end=\"2172\"\u003e  \u003cp data-start=\"2131\" data-end=\"2172\"\u003eThermal safety device required\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2173\" data-end=\"2204\"\u003e  \u003cp data-start=\"2175\" data-end=\"2204\"\u003eMaximum operating pressure: 2.5 bar\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2205\" data-end=\"2260\"\u003e  \u003cp data-start=\"2207\" data-end=\"2260\"\u003eMinimum chimney diameter: 150 mm (200 mm recommended)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2261\" data-end=\"2295\"\u003e  \u003cp data-start=\"2263\" data-end=\"2295\"\u003eRecommended chimney draft: 23–30 Pa\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2297\" data-end=\"2422\"\u003eTo ensure a long service life, a return temperature above 65 °C must be maintained. Recommended boiler temperature: 80–85 °C.\u003c\/p\u003e  \u003chr data-start=\"2424\" data-end=\"2427\"\u003e  \u003ch2 data-start=\"2429\" data-end=\"2450\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2452\" data-end=\"2563\"\u003eThe ATTACK SLX 20 LAMBDA meets the requirements of \u003cstrong data-start=\"2507\" data-end=\"2524\"\u003eEN 303-5:2012\u003c\/strong\u003e for boilers of fuel class A.\u003c\/p\u003e  \u003cp data-start=\"2565\" data-end=\"2598\"\u003eMeasurement values ​​according to the information sheet:\u003c\/p\u003e  \u003cul data-start=\"2600\" data-end=\"2748\"\u003e  \u003cli data-start=\"2600\" data-end=\"2630\"\u003e  \u003cp data-start=\"2602\" data-end=\"2630\"\u003eNominal heat output: 19.7 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2631\" data-end=\"2665\"\u003e  \u003cp data-start=\"2633\" data-end=\"2665\"\u003ePart load (30%\/50%): 9.7 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2666\" data-end=\"2707\"\u003e  \u003cp data-start=\"2668\" data-end=\"2707\"\u003eEfficiency at rated power: 81.9%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2708\" data-end=\"2748\"\u003e  \u003cp data-start=\"2710\" data-end=\"2748\"\u003eEfficiency at 30%\/50%: 82.4%\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2750\" data-end=\"2825\"\u003eLambda technology supports clean and efficient combustion.\u003c\/p\u003e  \u003chr data-start=\"2827\" data-end=\"2830\"\u003e  \u003ch2 data-start=\"2832\" data-end=\"2869\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"2871\" data-end=\"2971\"\u003eFor standard-compliant and efficient operation, the SLX 20 LAMBDA is usually combined with:\u003c\/p\u003e  \u003cul data-start=\"2973\" data-end=\"3106\"\u003e  \u003cli data-start=\"2973\" data-end=\"2991\"\u003e  \u003cp data-start=\"2975\" data-end=\"2991\"\u003eBuffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2992\" data-end=\"3031\"\u003e  \u003cp data-start=\"2994\" data-end=\"3031\"\u003eReturn flow booster\/mixing device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3032\" data-end=\"3063\"\u003e  \u003cp data-start=\"3034\" data-end=\"3063\"\u003eThermal safety device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3064\" data-end=\"3085\"\u003e  \u003cp data-start=\"3066\" data-end=\"3085\"\u003eSafety valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3086\" data-end=\"3106\"\u003e  \u003cp data-start=\"3088\" data-end=\"3106\"\u003eExpansion vessel\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3108\" data-end=\"3219\"\u003eSuitable \u003cstrong data-start=\"3117\" data-end=\"3178\"\u003eBuffer storage tanks, return temperature boosts and safety groups\u003c\/strong\u003e You can find them in our product range at gemashop.de.\u003c\/p\u003e  \u003chr data-start=\"3221\" data-end=\"3224\"\u003e  \u003ch2 data-start=\"3226\" data-end=\"3245\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3247\" data-end=\"3699\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3247\" data-end=\"3265\"\u003e  \u003ctr data-start=\"3247\" data-end=\"3265\"\u003e  \u003cth data-start=\"3247\" data-end=\"3257\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3257\" data-end=\"3265\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3285\" data-end=\"3699\"\u003e  \u003ctr data-start=\"3285\" data-end=\"3315\"\u003e  \u003ctd data-start=\"3285\" data-end=\"3298\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"3298\" data-end=\"3315\" data-col-size=\"sm\"\u003eATTACK s.r.o.\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3316\" data-end=\"3342\"\u003e  \u003ctd data-start=\"3316\" data-end=\"3325\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"3325\" data-end=\"3342\" data-col-size=\"sm\"\u003eSLX 20 LAMBDA\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3343\" data-end=\"3389\"\u003e  \u003ctd data-start=\"3343\" data-end=\"3356\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"3356\" data-end=\"3389\" data-col-size=\"sm\"\u003eWood gasification hot water boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3390\" data-end=\"3431\"\u003e  \u003ctd data-start=\"3390\" data-end=\"3403\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-start=\"3403\" data-end=\"3431\" data-col-size=\"sm\"\u003eFirewood ≤ 25% moisture content\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3432\" data-end=\"3463\"\u003e  \u003ctd data-start=\"3432\" data-end=\"3452\" data-col-size=\"sm\"\u003eNominal heat output\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3452\" data-end=\"3463\"\u003e19.7 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3464\" data-end=\"3493\"\u003e  \u003ctd data-start=\"3464\" data-end=\"3483\" data-col-size=\"sm\"\u003ePart load power\u003c\/td\u003e  \u003ctd data-start=\"3483\" data-end=\"3493\" data-col-size=\"sm\"\u003e9.7 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3494\" data-end=\"3532\"\u003e  \u003ctd data-start=\"3494\" data-end=\"3522\" data-col-size=\"sm\"\u003eEfficiency Rated Power\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3522\" data-end=\"3532\"\u003e81.9%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3533\" data-end=\"3567\"\u003e  \u003ctd data-start=\"3533\" data-end=\"3557\" data-col-size=\"sm\"\u003eEfficiency at partial load\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3557\" data-end=\"3567\"\u003e82.4%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3568\" data-end=\"3600\"\u003e  \u003ctd data-start=\"3568\" data-end=\"3589\" data-col-size=\"sm\"\u003eMaximum operating pressure.\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3589\" data-end=\"3600\"\u003e2.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3601\" data-end=\"3638\"\u003e  \u003ctd data-start=\"3601\" data-end=\"3628\" data-col-size=\"sm\"\u003eMinimum chimney diameter\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3628\" data-end=\"3638\"\u003e150 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3639\" data-end=\"3674\"\u003e  \u003ctd data-start=\"3639\" data-end=\"3662\" data-col-size=\"sm\"\u003eRecommended chimney draft\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3662\" data-end=\"3674\"\u003e23 Pa\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3675\" data-end=\"3699\"\u003e  \u003ctd data-start=\"3675\" data-end=\"3682\" data-col-size=\"sm\"\u003estandard\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3682\" data-end=\"3699\"\u003eEN 303-5:2012\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"3701\" data-end=\"3704\"\u003e  \u003ch2 data-start=\"3706\" data-end=\"3721\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"3723\" data-end=\"3805\"\u003e  \u003cli data-start=\"3723\" data-end=\"3760\"\u003e  \u003cp data-start=\"3725\" data-end=\"3760\"\u003eATTACK SLX 20 LAMBDA wood gasifier\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3761\" data-end=\"3784\"\u003e  \u003cp data-start=\"3763\" data-end=\"3784\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3785\" data-end=\"3805\"\u003e  \u003cp data-start=\"3787\" data-end=\"3805\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3807\" data-end=\"3810\"\u003e  \u003ch2 data-start=\"3812\" data-end=\"3845\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"3847\" data-end=\"3949\"\u003eInstallation and commissioning must only be carried out by a qualified specialist company.\u003c\/p\u003e  \u003cp data-start=\"3951\" data-end=\"3969\"\u003eImportant instructions:\u003c\/p\u003e  \u003cul data-start=\"3971\" data-end=\"4202\"\u003e  \u003cli data-start=\"3971\" data-end=\"4023\"\u003e  \u003cp data-start=\"3973\" data-end=\"4023\"\u003eThermal safety device absolutely necessary\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4024\" data-end=\"4090\"\u003e  \u003cp data-start=\"4026\" data-end=\"4090\"\u003eReturn temperature boost necessary to prevent condensation\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4091\" data-end=\"4128\"\u003e  \u003cp data-start=\"4093\" data-end=\"4128\"\u003eCompliance with chimney requirements\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4129\" data-end=\"4202\"\u003e  \u003cp data-start=\"4131\" data-end=\"4202\"\u003eRegular cleaning of ash box, turbulators and heat exchangers\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"4204\" data-end=\"4272\"\u003eThe warranty may be limited if the installation is improper.\u003c\/p\u003e  \u003chr data-start=\"4274\" data-end=\"4277\"\u003e  \u003ch2 data-start=\"4279\" data-end=\"4285\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"4287\" data-end=\"4418\"\u003e\u003cstrong data-start=\"4287\" data-end=\"4323\"\u003e1. What does lambda control mean?\u003c\/strong\u003e\u003cbr data-start=\"4323\" data-end=\"4326\"\u003eThe lambda sensor measures the oxygen content in the exhaust gas and automatically controls the air supply.\u003c\/p\u003e  \u003cp data-start=\"4420\" data-end=\"4506\"\u003e\u003cstrong data-start=\"4420\" data-end=\"4465\"\u003e2. What is the power output of the SLX 20 LAMBDA?\u003c\/strong\u003e\u003cbr data-start=\"4465\" data-end=\"4468\"\u003eThe nominal heat output is 19.7 kW.\u003c\/p\u003e  \u003cp data-start=\"4508\" data-end=\"4591\"\u003e\u003cstrong data-start=\"4508\" data-end=\"4547\"\u003e3. Which fuel is permitted?\u003c\/strong\u003e\u003cbr data-start=\"4547\" data-end=\"4550\"\u003eFirewood with a maximum moisture content of 25%.\u003c\/p\u003e  \u003cp data-start=\"4593\" data-end=\"4718\"\u003e\u003cstrong data-start=\"4593\" data-end=\"4633\"\u003e4. Is a buffer storage tank necessary?\u003c\/strong\u003e\u003cbr data-start=\"4633\" data-end=\"4636\"\u003eA buffer storage tank is recommended for efficient and compliant operation.\u003c\/p\u003e  \u003cp data-start=\"4720\" data-end=\"4778\"\u003e\u003cstrong data-start=\"4720\" data-end=\"4767\"\u003e5. What is the maximum operating pressure?\u003c\/strong\u003e\u003cbr data-start=\"4767\" data-end=\"4770\"\u003e2.5 bar.\u003c\/p\u003e  \u003cp data-start=\"4780\" data-end=\"4905\"\u003e\u003cstrong data-start=\"4780\" data-end=\"4830\"\u003e6. How often is cleaning required?\u003c\/strong\u003e\u003cbr data-start=\"4830\" data-end=\"4833\"\u003eEmpty the ash box daily, and clean the heat exchanger regularly according to the operating instructions.\u003c\/p\u003e  \u003chr data-start=\"4907\" data-end=\"4910\"\u003e  \u003ch2 data-start=\"4912\" data-end=\"4920\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"4922\" data-end=\"5208\"\u003eThe \u003cstrong data-start=\"4926\" data-end=\"4956\"\u003eATTACK SLX 20 LAMBDA 20 kW\u003c\/strong\u003e Combines proven wood gasification technology with modern lambda control. An efficient and convenient solution for sustainable heating with logs in single-family and two-family homes. Order now and benefit from automated combustion control.\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49418657792348,"sku":"ASLXL20","price":5325.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/SLXlambda-webrender.webp?v=1774512431"},{"product_id":"heizkessel-holz-atmos-holzvergaser-festbrennstoff-atmos-gs-gs","title":"Atmos GS15 wood gasifier – Efficient solid fuel boiler 🔥","description":"\u003ch2\u003eAtmos wood-fired boiler - GS15\u003c\/h2\u003e  \u003cp\u003e\u003cstrong\u003eAtmos wood-fired boiler - GS wood gasifier solid fuel\u003c\/strong\u003e These boilers are characterized by their efficient combustion and achieve an efficiency of up to 87.1%. They are specifically designed for the use of logs as fuel and rely on proven wood gasification technology.\u003c\/p\u003e  \u003cp\u003eThe building structure basically corresponds to the \u003cstrong\u003eATMOS GSE Series\u003c\/strong\u003e.  In comparison, the GS series does without an additional exhaust gas heat exchanger. Furthermore, the design of the ceramic components differs in both the combustion chamber and the filling chamber. Due to these differences, the GS wood gasifier achieves a slightly lower efficiency than the GSE model. Nevertheless, thanks to its reliability and attractive price-performance ratio, it is currently one of the most frequently chosen wood gasification boilers from the ATMOS brand.\u003c\/p\u003e  \u003cp\u003eThe ATMOS GS wood gasifier is particularly popular with users and impresses with its robust construction, ease of maintenance and high quality standard.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eAdvantages: Atmos wood-fired boiler - GS wood gasifier solid fuel\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eMade from high-quality 6 mm and 8 mm thick boiler steel for a long service life and high operational reliability.\u003c\/li\u003e  \u003cli\u003eThe large-sized filling chamber allows for the insertion of large logs and reduces refueling intervals.\u003c\/li\u003e  \u003cli\u003eDoor hinge is factory-installed on the left; however, the door hinge can be flexibly adjusted afterwards.\u003c\/li\u003e  \u003cli\u003eDurable and replaceable protective lining made of fireclay ceramic (up to 4 cm thick) in the filling and combustion chamber for improved heat protection and stability.\u003c\/li\u003e  \u003cli\u003eIntegrated safety heat exchanger 1\/2 for thermal protection and safe dissipation of excess heat\u003c\/li\u003e  \u003cli\u003eInnovative parallel and V-shaped combustion chamber geometry ensures optimal combustion behavior and minimizes the risk of hollow combustion.\u003c\/li\u003e  \u003cli\u003eComplete thermal insulation using effective mineral wool insulation reduces heat loss and increases efficiency.\u003c\/li\u003e  \u003cli\u003eThe automatic shut-off function switches off the boiler automatically after the wood has completely burned, increasing safety and comfort.\u003c\/li\u003e  \u003cli\u003eBoiler control panel already prepared for the connection of a weather-compensated control system, several heating circuits and a solar circuit.\u003c\/li\u003e  \u003cli\u003eComplies with standard EN303-5 and has CE-0036 certification.\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnical data\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eEnergy efficiency class A+\u003c\/li\u003e  \u003cli\u003eBoiler class 5\u003c\/li\u003e  \u003cli\u003eNominal heat output: 15 kW, ideally suited for single-family and two-family homes\u003c\/li\u003e  \u003cli\u003eEfficiency: 91.2% ensures efficient fuel utilization\u003c\/li\u003e  \u003cli\u003eTraction requirement: 16 Pa guarantees safe operation\u003c\/li\u003e  \u003cli\u003eRequired fuel: firewood\u003c\/li\u003e  \u003cli\u003eMaximum firewood length: 250 mm\u003c\/li\u003e  \u003cli\u003eExhaust gas temperature: 134 °C\u003c\/li\u003e  \u003cli\u003eExhaust gas mass flow: 0.01 kg\/s\u003c\/li\u003e  \u003cli\u003eHeight: 1280 mm\u003c\/li\u003e  \u003cli\u003eWidth: 678 mm\u003c\/li\u003e  \u003cli\u003eDepth: 670 mm\u003c\/li\u003e  \u003cli\u003eFlue pipe connection: 150\/152 mm – suitable for common chimney systems\u003c\/li\u003e  \u003cli\u003eWeight: 302.0 kg – robust device for continuous use\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eScope of delivery\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eAtmos GS 15 kW wood gasifier\u003c\/li\u003e  \u003cli\u003eAssembly \u0026amp; Operating instructions with information on commissioning and maintenance\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"900\" data-end=\"1109\"\u003e👉  \u003cstrong data-start=\"903\" data-end=\"950\"\u003eOrder commissioning now, along with the commissioning!\u003c\/strong\u003e\u003cbr data-start=\"950\" data-end=\"953\"\u003eWith the \u0026quot;Commissioning by ATMOS\u0026quot; service, you ensure that your boiler is optimally set up and that all technical requirements are met.\u003c\/p\u003e  \u003cp data-start=\"1111\" data-end=\"1305\"\u003eFurther information on the process, requirements and services can be found in our article on \u003cstrong data-start=\"1209\" data-end=\"1304\"\u003e[\u003ca href=\"https:\/\/gemashop.de\/products\/atmos-inbetriebnahme\" title=\"Atmos Inbetriebnahme\" rel=\"noopener\" target=\"_blank\"\u003eATMOS commissioning\u003c\/a\u003e]\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Atmos","offers":[{"title":"Default Title","offer_id":49423473213788,"sku":"01.05.15","price":3706.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/atmos-gs15-holzvergaser-effizienter-festbrennstoffkessel-2672627.webp?v=1770693024"},{"product_id":"heizkessel-holz-atmos-gs-holzvergaser-festbrennstoff-boilers","title":"Atmos GS20 wood gasifier – Efficient gasification boiler 🌿🔥","description":"\u003ch2\u003eAtmos wood-fired boiler - GS20\u003c\/h2\u003e  \u003cp\u003e\u003cstrong\u003eAtmos wood-fired boiler - GS wood gasifier solid fuel\u003c\/strong\u003e These are high-performance wood gasification boilers that achieve a maximum efficiency of up to 87.1% and are specifically designed for the efficient combustion of logs. These models are frequently used in modern heating systems and are considered a reliable solution for environmentally conscious wood heating.\u003c\/p\u003e  \u003cp\u003eThe design of the GS series is based on the well-known \u003cstrong\u003eATMOS GSE Series\u003c\/strong\u003e,  However, the GS variant does without an additional exhaust gas heat exchanger. Furthermore, the ceramic lining and shape of the filling and combustion chamber differ. While this results in a slightly lower efficiency compared to the GSE series, the quality of efficient wood gasification remains unchanged.\u003c\/p\u003e  \u003cp\u003eThanks to its solid construction and user-friendliness, the GS is now one of the most popular wood gasification boilers from the ATMOS brand for both private and commercial use.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eAdvantages: wood-fired boiler Atmos-GS wood gasifier solid fuel\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eRobust wood gasifier made from high-quality 6 mm and 8 mm boiler steel for a long service life\u003c\/li\u003e  \u003cli\u003eLarge filling space for convenient refuelling of longer pieces of firewood and extended burning time\u003c\/li\u003e  \u003cli\u003eDoor hinge is factory-set to left, but can easily be changed afterwards.\u003c\/li\u003e  \u003cli\u003eParticularly resistant, replaceable protective lining made of proven fireclay ceramic in the filling and combustion chamber (up to 4 cm thick), which supports longevity.\u003c\/li\u003e  \u003cli\u003eIntegrated safety heat exchanger (1\/2) for thermal relief valve, ensuring a high level of safety.\u003c\/li\u003e  \u003cli\u003eEfficient parallel and V-shaped combustion chamber geometry ensures optimal combustion and prevents hollow burning.\u003c\/li\u003e  \u003cli\u003eComprehensive thermal insulation using mineral wool insulation minimizes heat loss and increases the efficiency of the boiler.\u003c\/li\u003e  \u003cli\u003eAutomatic shut-off after the wood has completely burned down for even more safety and convenience.\u003c\/li\u003e  \u003cli\u003eBoiler control panel prepared for the integration of weather-compensated controls, with options for multiple heating circuits and the integration of a solar circuit.\u003c\/li\u003e  \u003cli\u003eComplies with the requirements of standard EN303-5 CE-0036 and stands for tested quality and safety.\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnical data\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eEnergy efficiency class A+\u003c\/li\u003e  \u003cli\u003eBoiler class 5\u003c\/li\u003e  \u003cli\u003eNominal heat output 20 kW\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eEfficiency 86.1%\u003c\/li\u003e  \u003cli\u003eTraction requirement 20 Pa\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eCO content 242 mg\/m³\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eDust emission 14 mg\/m³\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eRequired fuel: firewood\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eMaximum firewood length: 330 mm\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eExhaust gas temperature: 210 °C\u003c\/li\u003e  \u003cli\u003eExhaust gas mass flow: 0.012 kg\/s\u003c\/li\u003e  \u003cli\u003eHeight: 1280 mm\u003c\/li\u003e  \u003cli\u003eWidth: 678 mm\u003c\/li\u003e  \u003cli\u003eDepth: 758 mm\u003c\/li\u003e  \u003cli\u003eFlue pipe connection: 150\/152 mm\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eWeight: 343.0 kg\u003c\/span\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eScope of delivery\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eAtmos GS 20 kW wood gasifier\u003c\/li\u003e  \u003cli\u003eAssembly \u0026amp; User manual\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"900\" data-end=\"1109\"\u003e👉  \u003cstrong data-start=\"903\" data-end=\"950\"\u003eOrder commissioning now, along with the commissioning!\u0026amp;\u003cbr data-start=\"950\" data-end=\"953\"\u003eWith the \u0026quot;Commissioning by ATMOS\u0026quot; service, you ensure that your boiler is optimally set up and that all technical requirements are met.\u003c\/p\u003e  \u003cp data-start=\"1111\" data-end=\"1305\"\u003eFurther information on the process, requirements and services can be found in our article on \u003cstrong data-start=\"1209\" data-end=\"1304\"\u003e[\u003ca href=\"https:\/\/gemashop.de\/products\/atmos-inbetriebnahme\" title=\"Atmos Inbetriebnahme\" rel=\"noopener\" target=\"_blank\"\u003eATMOS commissioning\u003c\/a\u003e]\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Atmos","offers":[{"title":"Default Title","offer_id":49423482552668,"sku":"01.05.20","price":4302.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/atmos-holzvergaser-gs20-effizienter-vergaserkessel-3014935.webp?v=1770692595"},{"product_id":"rojek-pk-bio-20-holzvergaserkessel-20-kw","title":"ROJEK PK BIO 20 wood gasification boiler 20 kW for logs","description":"\u003cp data-start=\"837\" data-end=\"1111\"\u003eThe ROJEK PK BIO 20 is a modern wood gasification boiler with a nominal output of 20 kW for the efficient heating of single-family homes and small commercial units. It is designed for logs up to 530 mm in diameter and meets the requirements of EN 303-5 Class 5 as well as Ecodesign.\u003c\/p\u003e  \u003chr data-start=\"1113\" data-end=\"1116\"\u003e  \u003ch2 data-start=\"1118\" data-end=\"1142\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"1144\" data-end=\"1499\"\u003e⭐ 20 kW nominal output – ideal for single-family homes with moderate heating requirements\u003cbr data-start=\"1220\" data-end=\"1223\"\u003e⭐ Large combustion chamber (130 liters) – long burn time of 5–9 hours\u003cbr data-start=\"1289\" data-end=\"1292\"\u003e⭐ Upper filling chamber – convenient and quick loading\u003cbr data-start=\"1348\" data-end=\"1351\"\u003e⭐ EN 303-5 Class 5 \u0026amp; Ecodesign compliant – eligible for funding and future-proof\u003cbr data-start=\"1423\" data-end=\"1426\"\u003e⭐ Electronic control – precise and efficient combustion control\u003c\/p\u003e  \u003chr data-start=\"1501\" data-end=\"1504\"\u003e  \u003ch2 data-start=\"1506\" data-end=\"1536\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1538\" data-end=\"1788\"\u003eThe ROJEK PK BIO 20 is suitable for single-family homes, workshops, and smaller residential buildings with a heat demand of up to approximately 20 kW. It is designed for use in central heating systems and works optimally in combination with a buffer storage tank.\u003c\/p\u003e  \u003chr data-start=\"1790\" data-end=\"1793\"\u003e  \u003ch2 data-start=\"1795\" data-end=\"1816\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1818\" data-end=\"2097\"\u003eThe top-loading design makes filling the boiler particularly convenient. The generous combustion chamber volume allows for long burn times, thus reducing refueling intervals. The heat exchanger is easily cleaned via an external operating lever.\u003c\/p\u003e  \u003chr data-start=\"2099\" data-end=\"2102\"\u003e  \u003ch2 data-start=\"2104\" data-end=\"2128\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2130\" data-end=\"2402\"\u003eThe boiler operates on the proven wood gasification principle with electronic control. Approved according to EN 303-5 Class 5 and compliant with EU Regulation 2015\/1189 (Ecodesign).\u003cbr data-start=\"2305\" data-end=\"2308\"\u003eMaximum log length: 530 mm\u003cbr data-start=\"2340\" data-end=\"2343\"\u003eMaximum wood moisture content: 20%\u003cbr data-start=\"2365\" data-end=\"2368\"\u003eCalorific value of fuel: 14–18 MJ\/kg\u003c\/p\u003e  \u003chr data-start=\"2404\" data-end=\"2407\"\u003e  \u003ch2 data-start=\"2409\" data-end=\"2430\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2432\" data-end=\"2541\"\u003eRated power: 20 kW\u003cbr data-start=\"2451\" data-end=\"2454\"\u003eEfficiency at rated power: 83.1%\u003cbr data-start=\"2491\" data-end=\"2494\"\u003eSeasonal space heating energy efficiency: 79%\u003c\/p\u003e  \u003cp data-start=\"2543\" data-end=\"2626\"\u003eThe boiler meets the strict emission requirements of class 5 according to EN 303-5.\u003c\/p\u003e  \u003chr data-start=\"2628\" data-end=\"2631\"\u003e  \u003ch2 data-start=\"2633\" data-end=\"2652\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"2654\" data-end=\"2992\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"2654\" data-end=\"2672\"\u003e  \u003ctr data-start=\"2654\" data-end=\"2672\"\u003e  \u003cth data-start=\"2654\" data-end=\"2664\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"2664\" data-end=\"2672\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"2692\" data-end=\"2992\"\u003e  \u003ctr data-start=\"2692\" data-end=\"2714\"\u003e  \u003ctd data-start=\"2692\" data-end=\"2705\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2705\" data-end=\"2714\"\u003eROJEK\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2715\" data-end=\"2737\"\u003e  \u003ctd data-start=\"2715\" data-end=\"2724\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2724\" data-end=\"2737\"\u003ePK BIO 20\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2738\" data-end=\"2772\"\u003e  \u003ctd data-start=\"2738\" data-end=\"2750\" data-col-size=\"sm\"\u003eBoiler type\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2750\" data-end=\"2772\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2773\" data-end=\"2797\"\u003e  \u003ctd data-start=\"2773\" data-end=\"2788\" data-col-size=\"sm\"\u003eRated power\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2788\" data-end=\"2797\"\u003e20 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2798\" data-end=\"2825\"\u003e  \u003ctd data-start=\"2798\" data-end=\"2811\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2811\" data-end=\"2825\"\u003efirewood\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2826\" data-end=\"2859\"\u003e  \u003ctd data-start=\"2826\" data-end=\"2849\" data-col-size=\"sm\"\u003eMax. log length\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2849\" data-end=\"2859\"\u003e530 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2860\" data-end=\"2887\"\u003e  \u003ctd data-start=\"2860\" data-end=\"2878\" data-col-size=\"sm\"\u003eFilling chamber volume\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2878\" data-end=\"2887\"\u003e130 l\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2888\" data-end=\"2913\"\u003e  \u003ctd data-start=\"2888\" data-end=\"2903\" data-col-size=\"sm\"\u003eefficiency\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2903\" data-end=\"2913\"\u003e83.1%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2914\" data-end=\"2944\"\u003e  \u003ctd data-start=\"2914\" data-end=\"2936\" data-col-size=\"sm\"\u003eSeasonal efficiency\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2936\" data-end=\"2944\"\u003e79%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2945\" data-end=\"2973\"\u003e  \u003ctd data-start=\"2945\" data-end=\"2952\" data-col-size=\"sm\"\u003estandard\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2952\" data-end=\"2973\"\u003eEN 303-5 Class 5\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"2974\" data-end=\"2992\"\u003e  \u003ctd data-start=\"2974\" data-end=\"2986\" data-col-size=\"sm\"\u003eEcodesign\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"2986\" data-end=\"2992\"\u003eYes\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"2994\" data-end=\"2997\"\u003e  \u003ch2 data-start=\"2999\" data-end=\"3014\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"3016\" data-end=\"3127\"\u003e  \u003cli data-start=\"3016\" data-end=\"3054\"\u003e  \u003cp data-start=\"3018\" data-end=\"3054\"\u003eROJEK PK BIO 20 wood gasification boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3055\" data-end=\"3082\"\u003e  \u003cp data-start=\"3057\" data-end=\"3082\"\u003eElectronic control\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3083\" data-end=\"3106\"\u003e  \u003cp data-start=\"3085\" data-end=\"3106\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3107\" data-end=\"3127\"\u003e  \u003cp data-start=\"3109\" data-end=\"3127\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3129\" data-end=\"3132\"\u003e  \u003ch2 data-start=\"3134\" data-end=\"3140\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"3142\" data-end=\"3190\"\u003e\u003cstrong data-start=\"3142\" data-end=\"3176\"\u003eWhat is the permissible length of wood?\u003c\/strong\u003e\u003cbr data-start=\"3176\" data-end=\"3179\"\u003eUp to 530 mm.\u003c\/p\u003e  \u003cp data-start=\"3192\" data-end=\"3314\"\u003e\u003cstrong data-start=\"3192\" data-end=\"3223\"\u003eIs the boiler eligible for funding?\u003c\/strong\u003e\u003cbr data-start=\"3223\" data-end=\"3226\"\u003eIt meets EN 303-5 Class 5 and Ecodesign standards; national funding conditions are decisive.\u003c\/p\u003e  \u003cp data-start=\"3316\" data-end=\"3411\"\u003e\u003cstrong data-start=\"3316\" data-end=\"3356\"\u003eIs a buffer storage tank required?\u003c\/strong\u003e\u003cbr data-start=\"3356\" data-end=\"3359\"\u003eRecommended for efficient and standards-compliant operation.\u003c\/p\u003e  \u003cp data-start=\"3413\" data-end=\"3499\"\u003e\u003cstrong data-start=\"3413\" data-end=\"3447\"\u003eHow long does a filling burn?\u003c\/strong\u003e\u003cbr data-start=\"3447\" data-end=\"3450\"\u003eApproximately 5–9 hours, depending on fuel quality.\u003c\/p\u003e  \u003cp data-start=\"3501\" data-end=\"3553\"\u003e\u003cstrong data-start=\"3501\" data-end=\"3537\"\u003eWhat wood moisture content is permissible?\u003c\/strong\u003e\u003cbr data-start=\"3537\" data-end=\"3540\"\u003eMaximum 20%.\u003c\/p\u003e  \u003cp data-start=\"3555\" data-end=\"3642\"\u003e\u003cstrong data-start=\"3555\" data-end=\"3585\"\u003eHow is the cleaning done?\u003c\/strong\u003e\u003cbr data-start=\"3585\" data-end=\"3588\"\u003eVia external cleaning lever and cleaning door.\u003c\/p\u003e  \u003chr data-start=\"3644\" data-end=\"3647\"\u003e  \u003ch2 data-start=\"3649\" data-end=\"3657\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"3659\" data-end=\"3809\"\u003eThe ROJEK PK BIO 20 offers efficient wood gasification technology for smaller buildings and impresses with high efficiency and emission values ​​that comply with standards.\u003c\/p\u003e","brand":"Rojek","offers":[{"title":"Default Title","offer_id":49423823765852,"sku":"RJPKB20","price":5150.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/holzvergaser-rojek-pk-bio-20-kw-effizienter-kessel-fur-brennholz-3844008.png?v=1770692622"},{"product_id":"atmos-dc18gse-holzvergaserkessel-19kw","title":"ATMOS DC18GSE 18 kW Wood Gasification Boiler Wood Heating","description":"\u003ch2\u003eATMOS DC18GSE Wood Gasification Boiler 19 kW\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eATMOS DC18GSE Wood Gasification Boiler\u003c\/strong\u003e is a manually fed solid fuel boiler for the efficient combustion of firewood. With a rated heat output of 19 kW, this model is particularly suitable for single-family homes and smaller heating systems.\u003c\/p\u003e\n\u003cp\u003eThanks to modern wood gasification technology, the boiler achieves high efficiency levels and efficient energy utilization. The DC18GSE meets the requirements of the \u003cstrong\u003eBImSchV Stage II\u003c\/strong\u003e and achieves the \u003cstrong\u003eEnergy Efficiency Class A+\u003c\/strong\u003e. :contentReference[oaicite:2]{index=2}\u003c\/p\u003e\n\u003ch3\u003eHighlights \/ Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e⭐ Wood gasification boiler with 19 kW output for single-family homes\u003c\/li\u003e\n\u003cli\u003e⭐ Efficiency up to 91.5 % for efficient wood combustion\u003c\/li\u003e\n\u003cli\u003e⭐ Energy Efficiency Class A+ according to EU energy labeling\u003c\/li\u003e\n\u003cli\u003e⭐ suitable for firewood up to 330 mm in length\u003c\/li\u003e\n\u003cli\u003e⭐ meets BImSchV Stage II for modern solid fuel heating systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplication \u0026 Target Audience\u003c\/h2\u003e\n\u003cp\u003eThe ATMOS DC18GSE is a manually fed wood gasification boiler for modern heating systems using firewood.\u003c\/p\u003e\n\u003cp\u003eTypical applications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeating systems in single-family homes\u003c\/li\u003e\n\u003cli\u003eRenovation of existing wood heating systems\u003c\/li\u003e\n\u003cli\u003eNew builds with renewable heating technology\u003c\/li\u003e\n\u003cli\u003eHeating systems with buffer storage\u003c\/li\u003e\n\u003cli\u003eHeating systems in combination with radiators or underfloor heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstallation should be carried out by a qualified HVAC specialist.\u003c\/p\u003e\n\u003ch2\u003eEveryday Advantages\u003c\/h2\u003e\n\u003cp\u003eWood gasification boilers utilize the energy contained in wood particularly efficiently. In the ATMOS DC18GSE, the wood is first gasified and then completely combusted at high temperatures.\u003c\/p\u003e\n\u003cp\u003eThis technology ensures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ehigh energy yield from firewood\u003c\/li\u003e\n\u003cli\u003ereduced emissions\u003c\/li\u003e\n\u003cli\u003estable combustion\u003c\/li\u003e\n\u003cli\u003eeconomical heating operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe large filling chamber allows for convenient refilling of firewood and long burning intervals.\u003c\/p\u003e\n\u003ch2\u003eTechnology \u0026 Features\u003c\/h2\u003e\n\u003cp\u003eThe ATMOS DC18GSE is a classic wood gasification boiler with a suction fan to optimize the combustion process.\u003c\/p\u003e\n\u003cp\u003eImportant components include, among others:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuction fan to support combustion\u003c\/li\u003e\n\u003cli\u003eBoiler thermostat and safety thermostat\u003c\/li\u003e\n\u003cli\u003eFlue gas thermostat\u003c\/li\u003e\n\u003cli\u003eBelimo actuator for air control\u003c\/li\u003e\n\u003cli\u003eThermal discharge safety device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe boiler is operated with firewood with a moisture content of approximately 12–20 %.\u003c\/p\u003e\n\u003ch2\u003eEfficiency \u0026 Environment\u003c\/h2\u003e\n\u003cp\u003eThe wood gasification boiler achieves high energy efficiency through the two-stage combustion of wood.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy Efficiency Class: A+\u003c\/li\u003e\n\u003cli\u003eBoiler efficiency: up to 91.5 %\u003c\/li\u003e\n\u003cli\u003eMeets BImSchV Stage II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis makes the ATMOS DC18GSE suitable for modern heating systems with renewable fuels.\u003c\/p\u003e\n\u003ch2\u003eCompatibility \u0026 System Integration\u003c\/h2\u003e\n\u003cp\u003eThe wood gasification boiler is typically integrated into heating systems with buffer storage. This allows the generated heat to be optimally stored and distributed.\u003c\/p\u003e\n\u003cp\u003eTypical system combinations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuffer storage\u003c\/li\u003e\n\u003cli\u003eReturn temperature elevation\u003c\/li\u003e\n\u003cli\u003eRadiator heating\u003c\/li\u003e\n\u003cli\u003eUnderfloor heating\u003c\/li\u003e\n\u003cli\u003eThermal solar systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eATMOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDC18GSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eWood Gasification Boiler \/ Solid Fuel Boiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Heat Output\u003c\/td\u003e\n\u003ctd\u003e19 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUseful Heat Output\u003c\/td\u003e\n\u003ctd\u003e18.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e91.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Efficiency Class\u003c\/td\u003e\n\u003ctd\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eFirewood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Log Length\u003c\/td\u003e\n\u003ctd\u003e330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilling Chamber Volume\u003c\/td\u003e\n\u003ctd\u003e80 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Volume in Boiler\u003c\/td\u003e\n\u003ctd\u003e73 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Operating Pressure\u003c\/td\u003e\n\u003ctd\u003e2.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Return Temperature\u003c\/td\u003e\n\u003ctd\u003eminimum 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue Gas Connection\u003c\/td\u003e\n\u003ctd\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1281 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e680 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e820 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e376 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level\u003c\/td\u003e\n\u003ctd\u003e65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eScope of Delivery\u003c\/h2\u003e\n\u003cp\u003eAccording to the manufacturer, the scope of delivery includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eATMOS DC18GSE Wood Gasification Boiler\u003c\/li\u003e\n\u003cli\u003eIntegrated suction fan\u003c\/li\u003e\n\u003cli\u003eControl thermostats and safety devices\u003c\/li\u003e\n\u003cli\u003eCleaning cover and maintenance components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAccessories \u0026 System Recommendations\u003c\/h2\u003e\n\u003cp\u003eFor the optimal operation of a wood gasification boiler, additional system components are recommended.\u003c\/p\u003e\n\u003cdiv class=\"cross-sell\"\u003e\n\u003ch3\u003eCompatible System Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/pufferspeicher\"\u003eBuffer storage\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/ruecklaufanhebung\"\u003eReturn temperature elevation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/heizungszubehoer\"\u003eHeating accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eInstallation \u0026 Safety Notes\u003c\/h2\u003e\n\u003cp\u003eThe installation of the wood gasification boiler must be carried out by a qualified heating specialist. Operation is only permitted with suitable hydraulic integration, safety fittings, and sufficient chimney draft.\u003c\/p\u003e\n\u003cp\u003eThe minimum return temperature of 65 °C specified by the manufacturer must be observed.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is the output of the ATMOS DC18GSE?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe wood gasification boiler has a rated heat output of 19 kW.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat fuel does the boiler use?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe ATMOS DC18GSE is operated with firewood. Dry wood with 12–20 % residual moisture is recommended.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat log length is possible?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eAccording to the manufacturer, the maximum log length is 330 mm.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat energy efficiency class does the boiler have?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe wood gasification boiler has Energy Efficiency Class A+.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDoes the boiler meet legal emission requirements?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes, the ATMOS DC18GSE meets the requirements of BImSchV Stage II.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eIs a buffer storage required?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eFor wood gasification boilers, a buffer storage is generally recommended to efficiently store the generated heat.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Atmos","offers":[{"title":"with automatic ignition ACD 04","offer_id":49424058024284,"sku":"01.04.18-AZ","price":6069.0,"currency_code":"EUR","in_stock":true},{"title":"without","offer_id":49424057958748,"sku":"01.04.18","price":4919.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/holzvergaser-atmos-gse-serie-19-kw-effizient-heizen-mit-touch-regelung-5276165.png?v=1770692665"},{"product_id":"defro-optima-hg-holzvergaserkessel-19-kw","title":"Defro Optima HG wood gasification boiler 19 kW – sustainable wood heating 🌲🔥","description":"\u003ch2\u003eDefro Optima HG wood gasification boiler 19 kW\u003c\/h2\u003e  \u003cp\u003e\u003cstrong\u003eDefro Optima HG wood gasification boiler \u003c\/strong\u003e\u003c\/p\u003e  \u003ch3\u003eEligible for KfW funding\u003c\/h3\u003e  \u003cp\u003e\u003cstrong\u003eOptima HG wood gasification boilers as a sustainable, crisis-proof energy source – modern wood heating\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eWood represents a more cost-effective alternative to fossil fuels and, particularly in rural areas with abundant forests, offers the possibility of local sourcing. This leads to noticeable savings in heating costs and simultaneously reduces dependence on external energy suppliers. With a \u003cstrong\u003eDefro Optima wood gasifier\u003c\/strong\u003e Take control of your energy supply and be independent of oil or gas deliveries. The Optima HG is extremely versatile, as it is not only suitable for space heating, but can also be used for hot water preparation or in hybrid systems to support an existing central heating system.\u003c\/p\u003e  \u003cp\u003eDEFRO's innovative wood boilers are equipped with advanced combustion technology, ensuring optimal utilization of the wood fuel. High efficiency means you need less wood to meet your building's heating requirements. The result is a resource-saving and efficient heating system that reduces fuel consumption and, consequently, operating costs.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eThe wood boiler meets the requirements of the BImSchV Stage 2!\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eNationwide commissioning and installation via our customer service department \u003c\/strong\u003e\u003ci\u003e\u003cstrong\u003eupon request\u003c\/strong\u003e\u003c\/i\u003e\u003cstrong\u003e Possible! Delivery is made by truck and liftgate. \u003c\/strong\u003e\u003ci\u003e\u003cstrong\u003eto the curb\u003c\/strong\u003e\u003c\/i\u003e\u003cstrong\u003e. \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eThe boiler complies with the BImSchV2 and has an official CE declaration of conformity.\u003c\/strong\u003e\u003c\/p\u003e  \u003ch3\u003eOptima HG wood gasification boiler – advantages:\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eRobust and compact boiler body that allows for space-saving installation,\u003c\/li\u003e  \u003cli\u003eElectronic control including intelligent buffer storage control,\u003c\/li\u003e  \u003cli\u003eGenerously sized combustion chamber for longer burning time and convenient filling,\u003c\/li\u003e  \u003cli\u003eFactory-installed sight glass for visual inspection of the carburetor flame and monitoring of the combustion process,\u003c\/li\u003e  \u003cli\u003eSustainable and safe heat source: Wood heating is ideally suited for combination with heat pumps or existing oil or gas systems, thus supporting hybrid heating concepts.\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnical data\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eEnergy efficiency class: A+\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eBoiler class: 5\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eNominal heat output: 19 kW\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eEfficiency: 92.3%\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eTraction requirement: 16 Pa\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eCO content: 12.7%\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eApproved fuel: Firewood\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eMaximum firewood length: 330 mm\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eExhaust gas temperature: 125 °C\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eExhaust gas mass flow: 13.8 g\/s\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eHeight: 1460 mm\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eWidth: 620 mm\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eDepth: 995 mm\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eFlue pipe connection: 130 mm\u003cbr\u003e  \u003c\/li\u003e  \u003cli\u003eWeight: 430 kg\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eScope of delivery\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eGasification boiler 19 kW\u003c\/li\u003e  \u003cli\u003eAssembly \u0026amp; User manual\u003c\/li\u003e  \u003c\/ul\u003e","brand":"Defro","offers":[{"title":"Default Title","offer_id":49552796615004,"sku":"DOHG19","price":4249.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/defro-optima-hg-holzvergaserkessel-19-kw-nachhaltige-holzheizung-2807375.png?v=1770692789"},{"product_id":"rojek-ktp20-naturzugkessel-scheitholzkessel-20kw","title":"Natural draft boiler ROJEK KTP 20 log boiler 20 kW","description":"\u003ch2\u003eROJEK KTP 20 natural draft boiler for logs – 20 kW\u003c\/h2\u003e    \u003cp\u003e The \u003cstrong\u003eROJEK KTP 20\u003c\/strong\u003e is a robust, hand-fed \u003cstrong\u003eNatural draft boiler for firewood\u003c\/strong\u003e With a nominal output of 20 kW, the boiler operates without a fan, relying solely on natural chimney draft, and is suitable for the reliable heat supply of single-family homes, workshops, or small commercial units. \u003c\/p\u003e    \u003cp\u003e Unlike wood gasification boilers, the combustion in the KTP 20 is based on the classic \u003cstrong\u003enatural draft principle\u003c\/strong\u003e.  The combustion air is controlled via adjustable air dampers and a thermostatic draft regulator. This means the boiler technically operates as \u003cstrong\u003eLog-fired natural draft boiler\u003c\/strong\u003e with simple, durable technology. \u003c\/p\u003e    \u003ch3\u003eHighlights\u003c\/h3\u003e    \u003cul\u003e  \u003cli\u003e⭐ Natural draft boiler for firewood without a blower\u003c\/li\u003e  \u003cli\u003e⭐ 20 kW heating output for single-family homes and smaller buildings\u003c\/li\u003e  \u003cli\u003e⭐ Robust welded steel construction\u003c\/li\u003e  \u003cli\u003e⭐ Thermostatic draft regulator for power control\u003c\/li\u003e  \u003cli\u003e⭐ EN 303-5 certified solid fuel boiler\u003c\/li\u003e  \u003c\/ul\u003e    \u003ch2\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e    \u003cp\u003e The ROJEK KTP 20 is suitable for buildings with medium heating requirements. Typical applications include: \u003c\/p\u003e    \u003cul\u003e  \u003cli\u003ePrivate households and single-family homes\u003c\/li\u003e  \u003cli\u003eWorkshops and agricultural buildings\u003c\/li\u003e  \u003cli\u003eRenovation projects with existing chimney systems\u003c\/li\u003e  \u003cli\u003eWood heating systems with buffer storage\u003c\/li\u003e  \u003c\/ul\u003e    \u003cp\u003e The operation uses untreated firewood with a recommended maximum wood moisture content of 20%. \u003c\/p\u003e    \u003ch2\u003eEveryday benefits\u003c\/h2\u003e    \u003cp\u003e The natural draft boiler operates without complex electronics or fan technology. This makes the heating system particularly robust, low-maintenance, and durable. Output is regulated mechanically via the thermostatic draft regulator, which automatically controls the air supply. \u003c\/p\u003e    \u003cp\u003e The large combustion chamber allows for longer burning times, which significantly increases comfort in daily heating operation. \u003c\/p\u003e    \u003ch2\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e    \u003cp\u003e The boiler consists of a robust welded steel construction with a water-cooled grate. Combustion takes place conventionally via natural draft through the chimney. \u003c\/p\u003e    \u003cul\u003e  \u003cli\u003eadjustable primary and secondary air\u003c\/li\u003e  \u003cli\u003ethermostatic draft regulator RT3\u003c\/li\u003e  \u003cli\u003eintegrated pressure gauge and thermometer\u003c\/li\u003e  \u003cli\u003eAfter-cooling loop to protect against overheating\u003c\/li\u003e  \u003cli\u003eConnection flow\/return G 2\"\u003c\/li\u003e  \u003c\/ul\u003e    \u003cp\u003e The required chimney draft is approximately 8–12 Pa. \u003c\/p\u003e    \u003ch2\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e    \u003cp\u003e The boiler meets the requirements of the European standard. \u003cstrong\u003eEN 303-5\u003c\/strong\u003e for solid fuel boilers. \u003c\/p\u003e    \u003cul\u003e  \u003cli\u003eEfficiency: approx. 75%\u003c\/li\u003e  \u003cli\u003eEnergy efficiency class: A+\u003c\/li\u003e  \u003cli\u003eExhaust gas temperature at rated power: approx. 220–300 °C\u003c\/li\u003e  \u003c\/ul\u003e    \u003cp\u003e For efficient and low-emission operation, combination with a buffer storage system is recommended. \u003c\/p\u003e    \u003ch2\u003eTechnical data\u003c\/h2\u003e    \u003ctable\u003e  \u003ctr\u003e  \u003ctd\u003eManufacturer\u003c\/td\u003e  \u003ctd\u003eROJEK\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eModel\u003c\/td\u003e  \u003ctd\u003eKTP 20\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eBoiler type\u003c\/td\u003e  \u003ctd\u003eLog-fired natural draft boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eRated power\u003c\/td\u003e  \u003ctd\u003e20 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eMinimum performance\u003c\/td\u003e  \u003ctd\u003e12 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003ecombustion chamber volume\u003c\/td\u003e  \u003ctd\u003e47.9 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eWater volume\u003c\/td\u003e  \u003ctd\u003e98 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eMax. log length\u003c\/td\u003e  \u003ctd\u003e33 cm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eFlue pipe diameter\u003c\/td\u003e  \u003ctd\u003e159 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eMax. operating pressure\u003c\/td\u003e  \u003ctd\u003e2 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eMax.Operating temperature\u003c\/td\u003e  \u003ctd\u003e90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eWeight\u003c\/td\u003e  \u003ctd\u003e261 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/table\u003e    \u003ch2\u003eScope of delivery\u003c\/h2\u003e    \u003cul\u003e  \u003cli\u003eROJEK KTP 20 boiler\u003c\/li\u003e  \u003cli\u003eOperating instructions\u003c\/li\u003e  \u003cli\u003eThermostatic pull regulator RT3 with chain\u003c\/li\u003e  \u003cli\u003eHeating system outlet valve 1\/2\"\u003c\/li\u003e  \u003cli\u003eSide ceramics\u003c\/li\u003e  \u003cli\u003ealignment screws\u003c\/li\u003e  \u003c\/ul\u003e    \u003ch2\u003eAssembly and safety instructions\u003c\/h2\u003e    \u003cp\u003e Installation must be carried out by a qualified heating contractor. A safety group and a correctly installed after-cooling loop are required. \u003c\/p\u003e    \u003cp\u003e Only dry firewood may be used as fuel. The use of liquid fuels for kindling is prohibited. \u003c\/p\u003e    \u003ch2\u003eFAQ\u003c\/h2\u003e    \u003cdetails\u003e  \u003csummary\u003e\u003cstrong\u003eIs the ROJEK KTP 20 a wood gasifier?\u003c\/strong\u003e\u003c\/summary\u003e  \u003cp\u003eNo. The KTP 20 operates as a classic natural draft boiler for logs and not according to the wood gasification principle.\u003c\/p\u003e  \u003c\/details\u003e    \u003cdetails\u003e  \u003csummary\u003e\u003cstrong\u003eDoes the boiler require electricity?\u003c\/strong\u003e\u003c\/summary\u003e  \u003cp\u003eNot for the boiler operation itself. Electricity is only needed for the heating circulation pump.\u003c\/p\u003e  \u003c\/details\u003e    \u003cdetails\u003e  \u003csummary\u003e\u003cstrong\u003eWhat length of wood can be used?\u003c\/strong\u003e\u003c\/summary\u003e  \u003cp\u003eThe maximum log length is approximately 33 cm.\u003c\/p\u003e  \u003c\/details\u003e    \u003cdetails\u003e  \u003csummary\u003e\u003cstrong\u003eIs a buffer storage tank necessary?\u003c\/strong\u003e\u003c\/summary\u003e  \u003cp\u003eNot technically required, but recommended for efficient operation.\u003c\/p\u003e  \u003c\/details\u003e    \u003cdetails\u003e  \u003csummary\u003e\u003cstrong\u003eWhat chimney draft is required?\u003c\/strong\u003e\u003c\/summary\u003e  \u003cp\u003eThe recommended chimney draft is between 8 and 12 Pascals.\u003c\/p\u003e  \u003c\/details\u003e    \u003cdetails\u003e  \u003csummary\u003e\u003cstrong\u003eWhat is the optimal wood moisture content?\u003c\/strong\u003e\u003c\/summary\u003e  \u003cp\u003eA residual moisture content between 12% and 20% is recommended.\u003c\/p\u003e  \u003c\/details\u003e    \u003cdiv class=\"cross-sell\"\u003e  \u003ch3\u003eSuitable system components\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/pufferspeicher\"\u003eBuffer storage tanks for wood-fired heating systems\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/laddomat-ruecklaufanhebung\"\u003eReturn flow increase\/Laddomat\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/sicherheitsgruppen-heizung\"\u003eSafety groups for heating systems\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\u003ca href=\"https:\/\/gemashop.de\/collections\/heizungsregler\"\u003eHeating controllers and controls\u003c\/a\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/div\u003e","brand":"Rojek","offers":[{"title":"right \/ vertical","offer_id":49591553196380,"sku":"RKTP20TRRV","price":2749.0,"currency_code":"EUR","in_stock":true},{"title":"left \/ vertical","offer_id":49591553130844,"sku":"RKTP20TLRV","price":2749.0,"currency_code":"EUR","in_stock":true},{"title":"left \/ horizontal","offer_id":49591553163612,"sku":"RKTP20TLRH","price":2749.0,"currency_code":"EUR","in_stock":true},{"title":"right \/ horizontal","offer_id":49591553229148,"sku":"RKTP20TRRH","price":2749.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/vergaserkessel-rojek-ktp-20-kw-holzvergaser-fur-holz-kohle-briketts-7692012.webp?v=1770692593"},{"product_id":"attack-slx-kombikessel-fur-holz-und-pellets-20-kw","title":"Attack SLX combination boiler 20 kW – wood and pellets – efficient \u0026 versatile","description":"\u003ch2\u003eAttack SLX combination boiler for wood and pellets - efficiency and versatility\u003c\/h2\u003e  \u003cp\u003eThe combination boiler \u003cstrong\u003eAttack SLX Combi\u003c\/strong\u003e The Attack SLX Combi combines the advantages of a full-fledged wood gasification boiler with the option of switching to fully automatic pellet operation. Whether you use wood, briquettes, or wood pellets as fuel, the boiler offers high comfort and an impressive efficiency of up to 91.6%. With its robust construction using special boiler steel and numerous innovative features, the Attack SLX Combi is a reliable and user-friendly solution for all your heating needs.\u003c\/p\u003e  \u003ch3\u003eHigh efficiency and efficient heating\u003c\/h3\u003e  \u003cp\u003eThanks to the highly efficient tube heat exchanger with mechanical cleaning lever and advanced control, the Attack SLX achieves \u003cstrong\u003eCombination boiler \u003c\/strong\u003eOutstanding combustion efficiency. The integrated PID control continuously adjusts the fan speed, which, together with the fuzzy logic, ensures optimal energy utilization. The special turbulators in the heat exchanger slow down the exhaust gases and ensure maximum heat transfer to the heating water.\u003c\/p\u003e  \u003cp\u003eWith an impressive efficiency of over 91%, the boiler not only saves fuel costs but also represents an environmentally friendly heating solution, as wood and pellets are considered CO2-neutral fuels as biomass.\u003c\/p\u003e  \u003ch3\u003eFlexibility through wood and pellet operation\u003c\/h3\u003e  \u003cp\u003eThe Attack SLX Combi is particularly impressive due to its flexibility. In wood gasification mode, you can easily operate the boiler with logs or briquettes. A large-capacity loading chamber with a capacity of up to 200 liters is available for this purpose, suitable for logs up to 690 mm in length.\u003c\/p\u003e  \u003cp\u003eFor pellet operation, the boiler is equipped with a modern burner that is automatically supplied with pellets via an auger. Switching between the two operating modes is straightforward thanks to a swivel mechanism on the burner. This allows you to choose between manual and fully automatic operation at any time – depending on your personal preference and needs.\u003c\/p\u003e  \u003ch3\u003eConvenient fully automatic operation with pellets\u003c\/h3\u003e  \u003cp\u003eIn pellet mode, the Attack SLX Combi shines with its convenient, fully automatic operation. The burner ignites and extinguishes automatically to maintain the set temperature of the buffer tank. Burner cleaning is also fully automatic, significantly reducing maintenance.\u003c\/p\u003e  \u003cp\u003eWith optional control via a room thermostat, you can conveniently monitor and adjust boiler operation remotely without having to enter the boiler room. This increases user-friendliness and saves time.\u003c\/p\u003e  \u003ch3\u003eRobust construction for durability\u003c\/h3\u003e  \u003cp\u003eThe Attack SLX combination boiler is made of 6 mm thick, special boiler steel, ensuring a very long service life. The integrated cooling circuit safety device provides maximum operational safety and prevents overheating. With its well-designed and compact construction, the boiler is also space-saving and easy to install.\u003c\/p\u003e  \u003cp\u003eThe Attack SLX range is designed for durability and reliability, so you can benefit from an efficient heating experience for many years to come.\u003c\/p\u003e  \u003ch3\u003eInnovative control system for maximum efficiency\u003c\/h3\u003e  \u003cp\u003eThe boiler is equipped with a modern LCD display that clearly shows all important operating states and diagnostics. The control system allows for the regulation of two heating circuits as well as precise buffer tank control. Furthermore, the burner can be controlled either via a room thermostat or a temperature sensor.\u003c\/p\u003e  \u003cp\u003eThe innovative combination of PID control and fuzzy logic ensures continuous adjustment of combustion parameters to optimize heating performance and minimize losses. This allows the Attack SLX Combi to support not only efficient but also environmentally friendly combustion.\u003c\/p\u003e  \u003ch3\u003eEnvironmentally friendly and cost-saving\u003c\/h3\u003e  \u003cp\u003eWith its ability to flexibly combine wood and pellets, the Attack SLX Combi significantly reduces your heating costs per season. By using biomass as fuel, the boiler also contributes to environmental protection. Its low emissions and high energy efficiency ensure that the boiler meets stringent environmental standards.\u003c\/p\u003e  \u003cp\u003eAdditionally, the optional pellet hopper with a capacity of 500 liters offers extra convenience, as it allows for longer operating times without refilling.\u003c\/p\u003e  \u003ch3\u003eSummary\u003c\/h3\u003e  \u003cp\u003eThe \u003cstrong\u003eAttack SLX combination boiler for wood and pellets\u003c\/strong\u003e The Attack SLX Combi is a versatile and efficient heat generator that offers both high comfort and environmental friendliness. With its ability to switch between wood and pellet operation, it flexibly meets a variety of heating requirements. The robust materials and innovative control technology make the Attack SLX Combi a sustainable and durable solution for your heating needs.\u003c\/p\u003e  \u003cp\u003eIf you value efficiency, ease of use and environmental friendliness, the Attack SLX is the right choice.\u003cstrong\u003e Combination boiler\u003c\/strong\u003e The ideal choice for your home or investment.\u003c\/p\u003e  \u003ch3\u003eAdvantages\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eEasy fuel change – \u003c\/span\u003e\u003cem\u003e\u003cspan dir=\"auto\"\u003eWood\/Pellets\u003c\/span\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eFully automatic firing process\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eAutomatic burner cleaning\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eHigh combustion efficiency \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e92%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eWide range of performance \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e20, 25, 30, 35 kW\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eDry coating – protection against tar\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eLong burning time \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003efrom 8 to 12 hours\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eLarge cargo space up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e200 l\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e\/\u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e650 mm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eFireproof concrete molded parts, resistant to temperatures up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e1350 °C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003eTechnical basic data\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eNominal heat output: Wood 25 kW\/Pellets 30 kW\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eCargo compartment volume: 200 L\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eFilling opening: 235 x 445 mm\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eChimney flue: 23 PA\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eBoiler height: 1,472 mm\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eBoiler width: 703 mm\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eBoiler depth including burner: 1,650 mm\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eBoiler depth without burner: 1,350 mm\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eSmoke extraction height: 985 mm\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eFlue pipe connection: 150 mm\u003c\/span\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eScope of delivery\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eAttack pellet combi boiler 20 kW\u003c\/li\u003e  \u003cli\u003eContainer \u0026amp; auger (optional) \u003cul\u003e  \u003cli style=\"font-weight: bold;\"\u003e\u003ca title=\"Attack SLX Combi Pellet 20 kW Plus\" href=\"https:\/\/gemashop.de\/collections\/kombikessel-kombikessel\/products\/attack-slx-combi-pellet-20-kw-plus\"\u003e\u003cstrong\u003eComplete offer\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli\u003eAssembly \u0026amp; User manual\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \u003c\/p\u003e  \u003cstyle type=\"text\/css\"\u003e\n\ttable.tableizer-table {\n\t\tfont-size: 12px;\n\t\tborder: 1px solid #CCC; \n\t\tfont-family: Arial, Helvetica, sans-serif;\n\t} \n\t.tableizer-table td {\n\t\tpadding: 4px;\n\t\tmargin: 3px;\n\t\tborder: 1px solid #CCC;\n\t}\n\t.tableizer-table th {\n\t\tbackground-color: #104E8B; \n\t\tcolor: #FFF;\n\t\tfont-weight: bold;\n\t}\n\u003c\/style\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":53857022411100,"sku":"A20SLXCP","price":6760.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/SLXCP_Zaslepka.webp?v=1774511334"},{"product_id":"mpm-wood-plus-6-holzvergaserkessel-6kw","title":"MPM Wood Plus 6 kW wood gasification boiler - log boiler A+","description":"\u003cp data-start=\"706\" data-end=\"935\"\u003eThe MPM Wood Plus 6 is a modern wood gasification boiler with a nominal output of 6 kW for logs.\u003cbr data-start=\"799\" data-end=\"802\"\u003eIt meets Ecodesign requirements and achieves energy efficiency class A+. Ideal for single-family homes with buffer storage operation.\u003c\/p\u003e  \u003chr data-start=\"937\" data-end=\"940\"\u003e  \u003ch2 data-start=\"942\" data-end=\"966\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"968\" data-end=\"1302\"\u003e⭐ Efficient wood gasification with 82.9% efficiency at nominal output\u003cbr data-start=\"1035\" data-end=\"1038\"\u003e⭐ Energy efficiency class A+ (EEI 117) – complies with EU Ecodesign 2015\/1189\u003cbr data-start=\"1108\" data-end=\"1111\"\u003e⭐ Robust welded steel construction with ceramic burner\u003cbr data-start=\"1170\" data-end=\"1173\"\u003e\u0026amp; Suitable for open and closed operation (up to 1.5 bar)\u003cbr data-start=\"1235\" data-end=\"1238\"\u003e⭐ Optimized for buffer tank operation (minimum 300 liters recommended)\u003c\/p\u003e  \u003chr data-start=\"1304\" data-end=\"1307\"\u003e  \u003ch1 data-start=\"1309\" data-end=\"1348\"\u003eMPM Wood Plus 6 kW wood gasification boiler\u003c\/h1\u003e  \u003ch2 data-start=\"1350\" data-end=\"1380\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1382\" data-end=\"1547\"\u003eThe MPM Wood Plus 6 is a water-bearing wood gasification boiler with manual feeding for logs (moisture content ≤ 25%).\u003cbr data-start=\"1515\" data-end=\"1518\"\u003eIt is particularly suitable for:\u003c\/p\u003e  \u003cul data-start=\"1549\" data-end=\"1652\"\u003e  \u003cli data-start=\"1549\" data-end=\"1570\"\u003e  \u003cp data-start=\"1551\" data-end=\"1570\"\u003eSingle-family homes\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1571\" data-end=\"1593\"\u003e  \u003cp data-start=\"1573\" data-end=\"1593\"\u003esmall residential buildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1594\" data-end=\"1652\"\u003e  \u003cp data-start=\"1596\" data-end=\"1652\"\u003eWorkshops or commercial premises with low heating requirements\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"1654\" data-end=\"1745\"\u003eThe system operates exclusively at nominal power in conjunction with a buffer storage tank.\u003c\/p\u003e  \u003chr data-start=\"1747\" data-end=\"1750\"\u003e  \u003ch2 data-start=\"1752\" data-end=\"1773\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1775\" data-end=\"1970\"\u003eThe carburetor technology ensures a two-stage combustion:\u003cbr data-start=\"1834\" data-end=\"1837\"\u003eFirst, the wood is degassed, then the resulting wood gases are completely burned in a ceramic combustion chamber.\u003c\/p\u003e  \u003cp data-start=\"1972\" data-end=\"1985\"\u003eThe result:\u003c\/p\u003e  \u003cul data-start=\"1987\" data-end=\"2097\"\u003e  \u003cli data-start=\"1987\" data-end=\"2010\"\u003e  \u003cp data-start=\"1989\" data-end=\"2010\"\u003estable combustion\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2011\" data-end=\"2033\"\u003e  \u003cp data-start=\"2013\" data-end=\"2033\"\u003elow emissions\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2034\" data-end=\"2052\"\u003e  \u003cp data-start=\"2036\" data-end=\"2052\"\u003ehigh efficiency\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2053\" data-end=\"2097\"\u003e  \u003cp data-start=\"2055\" data-end=\"2097\"\u003eBurning time up to approx. 4 hours per filling\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2099\" data-end=\"2204\"\u003eWith a fuel consumption of approximately 1.5 kg\/h, the boiler operates economically and in a resource-saving manner.\u003c\/p\u003e  \u003chr data-start=\"2206\" data-end=\"2209\"\u003e  \u003ch2 data-start=\"2211\" data-end=\"2235\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2237\" data-end=\"2352\"\u003eThe MPM Wood Plus 6 is made of certified steel boiler plate in a welded construction.\u003cbr data-start=\"2324\" data-end=\"2327\"\u003eThe construction includes:\u003c\/p\u003e  \u003cul data-start=\"2354\" data-end=\"2629\"\u003e  \u003cli data-start=\"2354\" data-end=\"2401\"\u003e  \u003cp data-start=\"2356\" data-end=\"2401\"\u003elarge loading chamber (~30 dm³\/approx. 10 kg wood)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2402\" data-end=\"2426\"\u003e  \u003cp data-start=\"2404\" data-end=\"2426\"\u003emovable cast iron grate\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2427\" data-end=\"2453\"\u003e  \u003cp data-start=\"2429\" data-end=\"2453\"\u003eMetal-ceramic burner\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2454\" data-end=\"2507\"\u003e  \u003cp data-start=\"2456\" data-end=\"2507\"\u003evertical flue gas ducts with turbulence element\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2508\" data-end=\"2534\"\u003e  \u003cp data-start=\"2510\" data-end=\"2534\"\u003emechanical tension regulator\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2535\" data-end=\"2574\"\u003e  \u003cp data-start=\"2537\" data-end=\"2574\"\u003eThermometer in the upper boiler area\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2575\" data-end=\"2629\"\u003e  \u003cp data-start=\"2577\" data-end=\"2629\"\u003eDBV-1 connection for thermal overheating protection\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2631\" data-end=\"2680\"\u003eThermal insulation is provided by 40 mm of mineral wool.\u003c\/p\u003e  \u003chr data-start=\"2682\" data-end=\"2685\"\u003e  \u003ch2 data-start=\"2687\" data-end=\"2708\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2710\" data-end=\"2791\"\u003eThe boiler meets the requirements of Regulation (EU) 2015\/1189 (Ecodesign).\u003c\/p\u003e  \u003cp data-start=\"2793\" data-end=\"2811\"\u003eKey values:\u003c\/p\u003e  \u003cul data-start=\"2813\" data-end=\"3002\"\u003e  \u003cli data-start=\"2813\" data-end=\"2862\"\u003e  \u003cp data-start=\"2815\" data-end=\"2862\"\u003eSeasonal space heating energy efficiency: 80%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2863\" data-end=\"2893\"\u003e  \u003cp data-start=\"2865\" data-end=\"2893\"\u003eEnergy efficiency class: A+\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2894\" data-end=\"2930\"\u003e  \u003cp data-start=\"2896\" data-end=\"2930\"\u003eEnergy Efficiency Index (EEI): 117\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2931\" data-end=\"2947\"\u003e  \u003cp data-start=\"2933\" data-end=\"2947\"\u003ePM: 15 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2948\" data-end=\"2965\"\u003e  \u003cp data-start=\"2950\" data-end=\"2965\"\u003eOGC: 18 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2966\" data-end=\"2983\"\u003e  \u003cp data-start=\"2968\" data-end=\"2983\"\u003eCO: 653 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2984\" data-end=\"3002\"\u003e  \u003cp data-start=\"2986\" data-end=\"3002\"\u003eNOx: 163 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3004\" data-end=\"3058\"\u003eIt corresponds to class 5 according to PN-EN 303-5:2021-09.\u003c\/p\u003e  \u003chr data-start=\"3060\" data-end=\"3063\"\u003e  \u003ch2 data-start=\"3065\" data-end=\"3102\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"3104\" data-end=\"3146\"\u003eThe MPM Wood Plus 6 can be operated:\u003c\/p\u003e  \u003cul data-start=\"3148\" data-end=\"3265\"\u003e  \u003cli data-start=\"3148\" data-end=\"3173\"\u003e  \u003cp data-start=\"3150\" data-end=\"3173\"\u003ein the open heating system\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3174\" data-end=\"3265\"\u003e  \u003cp data-start=\"3176\" data-end=\"3265\"\u003ein a closed heating system (with diaphragm expansion vessel and safety devices)\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3267\" data-end=\"3298\"\u003eKey operational requirements:\u003c\/p\u003e  \u003cul data-start=\"3300\" data-end=\"3463\"\u003e  \u003cli data-start=\"3300\" data-end=\"3359\"\u003e  \u003cp data-start=\"3302\" data-end=\"3359\"\u003eRecommended buffer storage volume: at least 330 liters\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3360\" data-end=\"3398\"\u003e  \u003cp data-start=\"3362\" data-end=\"3398\"\u003eMinimum return temperature: 65 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3399\" data-end=\"3431\"\u003e  \u003cp data-start=\"3401\" data-end=\"3431\"\u003eOperating temperature: 60–90 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3432\" data-end=\"3463\"\u003e  \u003cp data-start=\"3434\" data-end=\"3463\"\u003eMaximum operating pressure: 1.5 bar\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3465\" data-end=\"3538\"\u003eA thermostatic anti-condensate valve (65 °C) is strongly recommended.\u003c\/p\u003e  \u003chr data-start=\"3540\" data-end=\"3543\"\u003e  \u003ch1 data-start=\"3545\" data-end=\"3563\"\u003eTechnical data\u003c\/h1\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3565\" data-end=\"4622\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3565\" data-end=\"3583\"\u003e  \u003ctr data-start=\"3565\" data-end=\"3583\"\u003e  \u003cth data-start=\"3565\" data-end=\"3575\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3575\" data-end=\"3583\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3603\" data-end=\"4622\"\u003e  \u003ctr data-start=\"3603\" data-end=\"3645\"\u003e  \u003ctd data-start=\"3603\" data-end=\"3616\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3616\" data-end=\"3645\"\u003eMPM Project Marcin Nykiel\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3646\" data-end=\"3670\"\u003e  \u003ctd data-start=\"3646\" data-end=\"3655\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3655\" data-end=\"3670\"\u003eWood Plus 6\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3671\" data-end=\"3706\"\u003e  \u003ctd data-start=\"3671\" data-end=\"3684\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3684\" data-end=\"3706\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3707\" data-end=\"3734\"\u003e  \u003ctd data-start=\"3707\" data-end=\"3726\" data-col-size=\"sm\"\u003eNominal heating output\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3726\" data-end=\"3734\"\u003e6 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3735\" data-end=\"3771\"\u003e  \u003ctd data-start=\"3735\" data-end=\"3761\" data-col-size=\"sm\"\u003eGenerated useful heat (Pn)\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3761\" data-end=\"3771\"\u003e6.2 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3772\" data-end=\"3803\"\u003e  \u003ctd data-start=\"3772\" data-end=\"3797\" data-col-size=\"sm\"\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd data-start=\"3797\" data-end=\"3803\" data-col-size=\"sm\"\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3804\" data-end=\"3841\"\u003e  \u003ctd data-start=\"3804\" data-end=\"3834\" data-col-size=\"sm\"\u003eEnergy Efficiency Index (EEI)\u003c\/td\u003e  \u003ctd data-start=\"3834\" data-end=\"3841\" data-col-size=\"sm\"\u003e117\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3842\" data-end=\"3879\"\u003e  \u003ctd data-start=\"3842\" data-end=\"3871\" data-col-size=\"sm\"\u003eSeasonal energy efficiency\u003c\/td\u003e  \u003ctd data-start=\"3871\" data-end=\"3879\" data-col-size=\"sm\"\u003e80%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3880\" data-end=\"3922\"\u003e  \u003ctd data-start=\"3880\" data-end=\"3912\" data-col-size=\"sm\"\u003eEfficiency at rated power\u003c\/td\u003e  \u003ctd data-start=\"3912\" data-end=\"3922\" data-col-size=\"sm\"\u003e82.9%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3923\" data-end=\"3958\"\u003e  \u003ctd data-start=\"3923\" data-end=\"3950\" data-col-size=\"sm\"\u003eThermal efficiency\u003c\/td\u003e  \u003ctd data-start=\"3950\" data-end=\"3958\" data-col-size=\"sm\"\u003e89%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3959\" data-end=\"4001\"\u003e  \u003ctd data-start=\"3959\" data-end=\"3974\" data-col-size=\"sm\"\u003eboiler class\u003c\/td\u003e  \u003ctd data-start=\"3974\" data-end=\"4001\" data-col-size=\"sm\"\u003e5 (PN-EN 303-5:2021-09)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4002\" data-end=\"4025\"\u003e  \u003ctd data-start=\"4002\" data-end=\"4015\" data-col-size=\"sm\"\u003eheating surface\u003c\/td\u003e  \u003ctd data-start=\"4015\" data-end=\"4025\" data-col-size=\"sm\"\u003e1.0 m²\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4026\" data-end=\"4062\"\u003e  \u003ctd data-start=\"4026\" data-end=\"4050\" data-col-size=\"sm\"\u003eWater quantity in the boiler\u003c\/td\u003e  \u003ctd data-start=\"4050\" data-end=\"4062\" data-col-size=\"sm\"\u003e40 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4063\" data-end=\"4080\"\u003e  \u003ctd data-start=\"4063\" data-end=\"4070\" data-col-size=\"sm\"\u003eHeight\u003c\/td\u003e  \u003ctd data-start=\"4070\" data-end=\"4080\" data-col-size=\"sm\"\u003e840 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4081\" data-end=\"4106\"\u003e  \u003ctd data-start=\"4081\" data-end=\"4096\" data-col-size=\"sm\"\u003eTotal width\u003c\/td\u003e  \u003ctd data-start=\"4096\" data-end=\"4106\" data-col-size=\"sm\"\u003e455 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4107\" data-end=\"4132\"\u003e  \u003ctd data-start=\"4107\" data-end=\"4121\" data-col-size=\"sm\"\u003eTotal length\u003c\/td\u003e  \u003ctd data-start=\"4121\" data-end=\"4132\" data-col-size=\"sm\"\u003e1020 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4133\" data-end=\"4157\"\u003e  \u003ctd data-start=\"4133\" data-end=\"4143\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e  \u003ctd data-start=\"4143\" data-end=\"4157\" data-col-size=\"sm\"\u003eapprox. 170 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4158\" data-end=\"4193\"\u003e  \u003ctd data-start=\"4158\" data-end=\"4179\" data-col-size=\"sm\"\u003eLoading chamber volume\u003c\/td\u003e  \u003ctd data-start=\"4179\" data-end=\"4193\" data-col-size=\"sm\"\u003eapprox. 30 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4194\" data-end=\"4236\"\u003e  \u003ctd data-start=\"4194\" data-end=\"4223\" data-col-size=\"sm\"\u003eRecommended buffer storage\u003c\/td\u003e  \u003ctd data-start=\"4223\" data-end=\"4236\" data-col-size=\"sm\"\u003e300 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4237\" data-end=\"4270\"\u003e  \u003ctd data-start=\"4237\" data-end=\"4258\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e  \u003ctd data-start=\"4258\" data-end=\"4270\" data-col-size=\"sm\"\u003e60–90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4271\" data-end=\"4306\"\u003e  \u003ctd data-start=\"4271\" data-end=\"4297\" data-col-size=\"sm\"\u003eMaximum operating temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4297\" data-end=\"4306\"\u003e90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4307\" data-end=\"4346\"\u003e  \u003ctd data-start=\"4307\" data-end=\"4337\" data-col-size=\"sm\"\u003eMinimum return temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4337\" data-end=\"4346\"\u003e55 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4347\" data-end=\"4379\"\u003e  \u003ctd data-start=\"4347\" data-end=\"4368\" data-col-size=\"sm\"\u003eMax. operating pressure\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4368\" data-end=\"4379\"\u003e1.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4380\" data-end=\"4414\"\u003e  \u003ctd data-start=\"4380\" data-end=\"4405\" data-col-size=\"sm\"\u003eFlow\/return connection\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4405\" data-end=\"4414\"\u003e40 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4415\" data-end=\"4447\"\u003e  \u003ctd data-start=\"4415\" data-end=\"4433\" data-col-size=\"sm\"\u003eExhaust gas temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4433\" data-end=\"4447\"\u003e100–120 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4448\" data-end=\"4494\"\u003e  \u003ctd data-start=\"4448\" data-end=\"4472\" data-col-size=\"sm\"\u003eExhaust system required\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4472\" data-end=\"4494\"\u003eapprox. 0.19–0.20 mbar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4495\" data-end=\"4546\"\u003e  \u003ctd data-start=\"4495\" data-end=\"4519\" data-col-size=\"sm\"\u003eMinimum chimney dimensions\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4519\" data-end=\"4546\"\u003e160x160 mm or Ø140 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4547\" data-end=\"4579\"\u003e  \u003ctd data-start=\"4547\" data-end=\"4572\" data-col-size=\"sm\"\u003eMinimum chimney height\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4572\" data-end=\"4579\"\u003e7 m\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4580\" data-end=\"4622\"\u003e  \u003ctd data-start=\"4580\" data-end=\"4593\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4593\" data-end=\"4622\"\u003eFirewood ≤ 25% moisture\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"4624\" data-end=\"4627\"\u003e  \u003ch2 data-start=\"4629\" data-end=\"4644\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"4646\" data-end=\"4731\"\u003e  \u003cli data-start=\"4646\" data-end=\"4684\"\u003e  \u003cp data-start=\"4648\" data-end=\"4684\"\u003eMPM Wood Plus 6 wood gasification boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4685\" data-end=\"4708\"\u003e  \u003cp data-start=\"4687\" data-end=\"4708\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4709\" data-end=\"4731\"\u003e  \u003cp data-start=\"4711\" data-end=\"4731\"\u003eWarranty documents\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"4733\" data-end=\"4736\"\u003e  \u003ch2 data-start=\"4738\" data-end=\"4761\"\u003eAccesories \u0026amp; Recommendation\u003c\/h2\u003e  \u003cp data-start=\"4763\" data-end=\"4818\"\u003eFor optimal and safe operation, we recommend:\u003c\/p\u003e  \u003cul data-start=\"4820\" data-end=\"5026\"\u003e  \u003cli data-start=\"4820\" data-end=\"4851\"\u003e  \u003cp data-start=\"4822\" data-end=\"4851\"\u003eBuffer storage tank from 300 liters\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4852\" data-end=\"4898\"\u003e  \u003cp data-start=\"4854\" data-end=\"4898\"\u003eThermostatic anti-condensate valve 55 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4899\" data-end=\"4925\"\u003e  \u003cp data-start=\"4901\" data-end=\"4925\"\u003eDBV-1 Thermostatic Valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4926\" data-end=\"4953\"\u003e  \u003cp data-start=\"4928\" data-end=\"4953\"\u003eReturn flow boosting group\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4954\" data-end=\"4986\"\u003e  \u003cp data-start=\"4956\" data-end=\"4986\"\u003eDraft regulator for chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4987\" data-end=\"5026\"\u003e  \u003cp data-start=\"4989\" data-end=\"5026\"\u003eAcid-resistant chimney liner\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5028\" data-end=\"5088\"\u003eSuitable components can be found at:\u003cbr data-start=\"5066\" data-end=\"5069\"\u003e\u003ca data-start=\"5069\" data-end=\"5088\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/gemashop.de\"\u003ehttps:\/\/gemashop.de\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse href=\"\/cdn\/assets\/sprites-core-eri7ssmm.svg#304883\" fill=\"currentColor\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e  \u003chr data-start=\"5090\" data-end=\"5093\"\u003e  \u003ch2 data-start=\"5095\" data-end=\"5128\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cul data-start=\"5130\" data-end=\"5446\"\u003e  \u003cli data-start=\"5130\" data-end=\"5194\"\u003e  \u003cp data-start=\"5132\" data-end=\"5194\"\u003eInstallation exclusively by a qualified specialist company\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5195\" data-end=\"5229\"\u003e  \u003cp data-start=\"5197\" data-end=\"5229\"\u003eOperation only with buffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5230\" data-end=\"5270\"\u003e  \u003cp data-start=\"5232\" data-end=\"5270\"\u003eReturn temperature continuously ≥ 65 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5271\" data-end=\"5335\"\u003e  \u003cp data-start=\"5273\" data-end=\"5335\"\u003eSafety distance to flammable materials: at least 1 m\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5336\" data-end=\"5381\"\u003e  \u003cp data-start=\"5338\" data-end=\"5381\"\u003eChimney draft of approximately 0.20 mbar required\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5382\" data-end=\"5446\"\u003e  \u003cp data-start=\"5384\" data-end=\"5446\"\u003eNo operation with plastics or unsuitable fuels\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5448\" data-end=\"5489\"\u003eFailure to comply will result in loss of warranty.\u003c\/p\u003e  \u003chr data-start=\"5491\" data-end=\"5494\"\u003e  \u003ch1 data-start=\"5496\" data-end=\"5501\"\u003eFAQ\u003c\/h1\u003e  \u003cp data-start=\"5503\" data-end=\"5669\"\u003e\u003cstrong data-start=\"5503\" data-end=\"5546\"\u003e1.Is the MPM Wood Plus 6 eligible for funding?\u003c\/strong\u003e\u003cbr data-start=\"5546\" data-end=\"5549\"\u003eIt meets Ecodesign requirements and energy efficiency class A+. National funding conditions must be checked individually.\u003c\/p\u003e  \u003cp data-start=\"5671\" data-end=\"5798\"\u003e\u003cstrong data-start=\"5671\" data-end=\"5709\"\u003e2. Is a buffer storage tank mandatory?\u003c\/strong\u003e\u003cbr data-start=\"5709\" data-end=\"5712\"\u003eYes. Operation is only possible with a buffer tank of at least 300 liters.\u003c\/p\u003e  \u003cp data-start=\"5800\" data-end=\"5950\"\u003e\u003cstrong data-start=\"5800\" data-end=\"5864\"\u003e3. Can the boiler be operated in a closed system?\u003c\/strong\u003e\u003cbr data-start=\"5864\" data-end=\"5867\"\u003eYes, with a diaphragm expansion vessel, safety valve and thermal relief valve.\u003c\/p\u003e  \u003cp data-start=\"5952\" data-end=\"6089\"\u003e\u003cstrong data-start=\"5952\" data-end=\"5994\"\u003e4. Which type of wood may be used?\u003c\/strong\u003e\u003cbr data-start=\"5994\" data-end=\"5997\"\u003eFirewood with a maximum moisture content of 25%, ideally air-dried for at least two years.\u003c\/p\u003e  \u003cp data-start=\"6091\" data-end=\"6186\"\u003e\u003cstrong data-start=\"6091\" data-end=\"6128\"\u003e5. What is the efficiency?\u003c\/strong\u003e\u003cbr data-start=\"6128\" data-end=\"6131\"\u003e82.9% at rated power; thermal efficiency 89%.\u003c\/p\u003e  \u003cp data-start=\"6188\" data-end=\"6301\"\u003e\u003cstrong data-start=\"6188\" data-end=\"6238\"\u003e6. What return temperature is required?\u003c\/strong\u003e\u003cbr data-start=\"6238\" data-end=\"6241\"\u003eAt least 55 °C to avoid low-temperature corrosion.\u003c\/p\u003e  \u003cp data-start=\"6303\" data-end=\"6417\"\u003e\u003cstrong data-start=\"6303\" data-end=\"6340\"\u003e7. How long does a filling burn?\u003c\/strong\u003e\u003cbr data-start=\"6340\" data-end=\"6343\"\u003eUp to approximately 4 hours, depending on fuel quality and system design.\u003c\/p\u003e  \u003chr data-start=\"6419\" data-end=\"6422\"\u003e  \u003ch2 data-start=\"6424\" data-end=\"6432\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"6434\" data-end=\"6659\"\u003eThe MPM Wood Plus 6 is a compact, Ecodesign-compliant wood gasification boiler for smaller buildings with buffer storage operation.\u003cbr data-start=\"6559\" data-end=\"6562\"\u003eAn efficient, robust and technically sophisticated solution for sustainable heating with firewood.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":54128283353436,"sku":"MPMWP6","price":1920.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-wood-plus-14-kw-holzvergaserkessel-a-klasse-5-o178-2565436.webp?v=1770691938"},{"product_id":"mpm-wood-plus-10-holzvergaserkessel-10kw","title":"MPM Wood Plus 10 wood gasification boiler 10 kW A+","description":"\u003cp data-start=\"802\" data-end=\"1086\"\u003eThe MPM Wood Plus 10 is a modern wood gasification boiler with a nominal output of 10 kW for single-family homes and smaller buildings.\u003cbr data-start=\"925\" data-end=\"928\"\u003eIt meets the Ecodesign requirements according to EU Regulation 2015\/1189, achieves energy efficiency class A+ and is designed for operation with a buffer storage tank.\u003c\/p\u003e  \u003chr data-start=\"1088\" data-end=\"1091\"\u003e  \u003ch1 data-start=\"1093\" data-end=\"1116\"\u003eHighlights\/Advantages\u003c\/h1\u003e  \u003cp data-start=\"1118\" data-end=\"1431\"\u003e⭐ Efficient wood gasification with 10 kW nominal output for residential buildings\u003cbr data-start=\"1183\" data-end=\"1186\"\u003e⭐ Energy efficiency class A+ and EEI 117 for economical operation\u003cbr data-start=\"1254\" data-end=\"1257\"\u003e⭐ Ecodesign 2023 \u0026amp; Class 5 according to PN-EN 303-5:2021-09\u003cbr data-start=\"1309\" data-end=\"1312\"\u003e⭐ Robust welded steel construction with ceramic burner\u003cbr data-start=\"1371\" data-end=\"1374\"\u003e⭐ Operation possible in open and closed systems\u003c\/p\u003e  \u003chr data-start=\"1433\" data-end=\"1436\"\u003e  \u003ch1 data-start=\"1438\" data-end=\"1465\"\u003eDetailed description\u003c\/h1\u003e  \u003ch2 data-start=\"1467\" data-end=\"1497\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1499\" data-end=\"1630\"\u003eThe MPM Wood Plus 10 is a low-temperature water boiler for solid fuels with manual feeding. It is suitable for:\u003c\/p\u003e  \u003cul data-start=\"1632\" data-end=\"1723\"\u003e  \u003cli data-start=\"1632\" data-end=\"1653\"\u003e  \u003cp data-start=\"1634\" data-end=\"1653\"\u003eSingle-family homes\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1654\" data-end=\"1683\"\u003e  \u003cp data-start=\"1656\" data-end=\"1683\"\u003esmaller commercial units\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1684\" data-end=\"1699\"\u003e  \u003cp data-start=\"1686\" data-end=\"1699\"\u003eworkshops\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1700\" data-end=\"1723\"\u003e  \u003cp data-start=\"1702\" data-end=\"1723\"\u003eRestaurants\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"1725\" data-end=\"1871\"\u003eThe boiler is approved for open and closed heating systems according to PN-EN 12828 and may be operated with a maximum operating pressure of 1.5 bar.\u003c\/p\u003e  \u003chr data-start=\"1873\" data-end=\"1876\"\u003e  \u003ch2 data-start=\"1878\" data-end=\"1899\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1901\" data-end=\"1984\"\u003eThe wood gasification principle involves combustion in two separate chambers:\u003c\/p\u003e  \u003col data-start=\"1986\" data-end=\"2078\"\u003e  \u003cli data-start=\"1986\" data-end=\"2011\"\u003e  \u003cp data-start=\"1989\" data-end=\"2011\"\u003eDegassing of the wood\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2012\" data-end=\"2078\"\u003e  \u003cp data-start=\"2015\" data-end=\"2078\"\u003eAfterburning of wood gases in a ceramic combustion chamber\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ol\u003e  \u003cp data-start=\"2080\" data-end=\"2168\"\u003eThis enables clean and efficient combustion with reduced emission levels:\u003c\/p\u003e  \u003cul data-start=\"2170\" data-end=\"2241\"\u003e  \u003cli data-start=\"2170\" data-end=\"2186\"\u003e  \u003cp data-start=\"2172\" data-end=\"2186\"\u003ePM: 13 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2187\" data-end=\"2204\"\u003e  \u003cp data-start=\"2189\" data-end=\"2204\"\u003eOGC: 16 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2205\" data-end=\"2222\"\u003e  \u003cp data-start=\"2207\" data-end=\"2222\"\u003eCO: 438 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2223\" data-end=\"2241\"\u003e  \u003cp data-start=\"2225\" data-end=\"2241\"\u003eNOx: 149 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2243\" data-end=\"2381\"\u003eThe large loading chamber (~42 dm³) allows a burning time of up to 5 hours with an average fuel consumption of 2.8 kg\/h.\u003c\/p\u003e  \u003chr data-start=\"2383\" data-end=\"2386\"\u003e  \u003ch2 data-start=\"2388\" data-end=\"2412\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2414\" data-end=\"2509\"\u003eThe boiler is made of certified steel boiler plate in welded construction and features:\u003c\/p\u003e  \u003cul data-start=\"2511\" data-end=\"2708\"\u003e  \u003cli data-start=\"2511\" data-end=\"2537\"\u003e  \u003cp data-start=\"2513\" data-end=\"2537\"\u003eMetal-ceramic burner\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2538\" data-end=\"2594\"\u003e  \u003cp data-start=\"2540\" data-end=\"2594\"\u003evertical convection channels with turbulence unit\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2595\" data-end=\"2621\"\u003e  \u003cp data-start=\"2597\" data-end=\"2621\"\u003emechanical train regulator\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2622\" data-end=\"2637\"\u003e  \u003cp data-start=\"2624\" data-end=\"2637\"\u003ethermometer\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2638\" data-end=\"2683\"\u003e  \u003cp data-start=\"2640\" data-end=\"2683\"\u003eConnection sleeve for DBV-1 thermostatic valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2684\" data-end=\"2708\"\u003e  \u003cp data-start=\"2686\" data-end=\"2708\"\u003emovable cast iron grate\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2710\" data-end=\"2737\"\u003eKey operating parameters:\u003c\/p\u003e  \u003cul data-start=\"2739\" data-end=\"2879\"\u003e  \u003cli data-start=\"2739\" data-end=\"2771\"\u003e  \u003cp data-start=\"2741\" data-end=\"2771\"\u003eOperating temperature: 60–90 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2772\" data-end=\"2809\"\u003e  \u003cp data-start=\"2774\" data-end=\"2809\"\u003eMinimum return temperature: 55 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2810\" data-end=\"2841\"\u003e  \u003cp data-start=\"2812\" data-end=\"2841\"\u003eMaximum operating pressure: 1.5 bar\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2842\" data-end=\"2879\"\u003e  \u003cp data-start=\"2844\" data-end=\"2879\"\u003eWater volume in the boiler: 63 liters\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"2881\" data-end=\"2884\"\u003e  \u003ch2 data-start=\"2886\" data-end=\"2907\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2909\" data-end=\"2938\"\u003eThe MPM Wood Plus 10 fulfills:\u003c\/p\u003e  \u003cul data-start=\"2940\" data-end=\"3072\"\u003e  \u003cli data-start=\"2940\" data-end=\"2981\"\u003e  \u003cp data-start=\"2942\" data-end=\"2981\"\u003eRegulation (EU) 2015\/1189 (Ecodesign)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2982\" data-end=\"3034\"\u003e  \u003cp data-start=\"2984\" data-end=\"3034\"\u003eRegulation (EU) 2015\/1187 (Energy Labelling)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3035\" data-end=\"3072\"\u003e  \u003cp data-start=\"3037\" data-end=\"3072\"\u003eClass 5 according to PN-EN 303-5:2021-09\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3074\" data-end=\"3100\"\u003eTechnical efficiency values:\u003c\/p\u003e  \u003cul data-start=\"3102\" data-end=\"3224\"\u003e  \u003cli data-start=\"3102\" data-end=\"3138\"\u003e  \u003cp data-start=\"3104\" data-end=\"3138\"\u003eSeasonal energy efficiency: 80%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3139\" data-end=\"3180\"\u003e  \u003cp data-start=\"3141\" data-end=\"3180\"\u003eEfficiency at rated power: 82.9%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3181\" data-end=\"3211\"\u003e  \u003cp data-start=\"3183\" data-end=\"3211\"\u003eEnergy efficiency class: A+\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3212\" data-end=\"3224\"\u003e  \u003cp data-start=\"3214\" data-end=\"3224\"\u003eEEI: 117\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3226\" data-end=\"3289\"\u003eThe exhaust gas temperature at rated power is between 100–120 °C.\u003c\/p\u003e  \u003chr data-start=\"3291\" data-end=\"3294\"\u003e  \u003ch2 data-start=\"3296\" data-end=\"3333\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"3335\" data-end=\"3387\"\u003eOperation with a buffer storage tank is mandatory.\u003c\/p\u003e  \u003cp data-start=\"3389\" data-end=\"3433\"\u003eRecommended buffer volume:\u003cbr data-start=\"3415\" data-end=\"3418\"\u003e500–600 liters\u003c\/p\u003e  \u003cp data-start=\"3435\" data-end=\"3463\"\u003eThe boiler is suitable for:\u003c\/p\u003e  \u003cul data-start=\"3465\" data-end=\"3598\"\u003e  \u003cli data-start=\"3465\" data-end=\"3487\"\u003e  \u003cp data-start=\"3467\" data-end=\"3487\"\u003eOpen heating systems\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3488\" data-end=\"3543\"\u003e  \u003cp data-start=\"3490\" data-end=\"3543\"\u003eClosed heating systems with safety features\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3544\" data-end=\"3598\"\u003e  \u003cp data-start=\"3546\" data-end=\"3598\"\u003eIntegration into hot water systems via heat exchangers\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3600\" data-end=\"3653\"\u003eRequired chimney draft:\u003cbr data-start=\"3630\" data-end=\"3633\"\u003eapprox. 0.17–0.22 mbar\u003c\/p\u003e  \u003cp data-start=\"3655\" data-end=\"3733\"\u003eMinimum chimney height: 7 m\u003cbr data-start=\"3683\" data-end=\"3686\"\u003eMinimum cross-sectional area: 180 × 180 mm or Ø178 mm\u003c\/p\u003e  \u003chr data-start=\"3735\" data-end=\"3738\"\u003e  \u003ch1 data-start=\"3740\" data-end=\"3758\"\u003eTechnical data\u003c\/h1\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3760\" data-end=\"4658\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3760\" data-end=\"3778\"\u003e  \u003ctr data-start=\"3760\" data-end=\"3778\"\u003e  \u003cth data-start=\"3760\" data-end=\"3770\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3770\" data-end=\"3778\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3798\" data-end=\"4658\"\u003e  \u003ctr data-start=\"3798\" data-end=\"3840\"\u003e  \u003ctd data-start=\"3798\" data-end=\"3811\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"3811\" data-end=\"3840\" data-col-size=\"sm\"\u003eMPM Project Marcin Nykiel\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3841\" data-end=\"3866\"\u003e  \u003ctd data-start=\"3841\" data-end=\"3850\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"3850\" data-end=\"3866\" data-col-size=\"sm\"\u003eWood Plus 10\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3867\" data-end=\"3902\"\u003e  \u003ctd data-start=\"3867\" data-end=\"3880\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"3880\" data-end=\"3902\" data-col-size=\"sm\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3903\" data-end=\"3931\"\u003e  \u003ctd data-start=\"3903\" data-end=\"3922\" data-col-size=\"sm\"\u003eNominal heating output\u003c\/td\u003e  \u003ctd data-start=\"3922\" data-end=\"3931\" data-col-size=\"sm\"\u003e10 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3932\" data-end=\"3963\"\u003e  \u003ctd data-start=\"3932\" data-end=\"3957\" data-col-size=\"sm\"\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd data-start=\"3957\" data-end=\"3963\" data-col-size=\"sm\"\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3964\" data-end=\"4001\"\u003e  \u003ctd data-start=\"3964\" data-end=\"3994\" data-col-size=\"sm\"\u003eEnergy Efficiency Index (EEI)\u003c\/td\u003e  \u003ctd data-start=\"3994\" data-end=\"4001\" data-col-size=\"sm\"\u003e117\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4002\" data-end=\"4039\"\u003e  \u003ctd data-start=\"4002\" data-end=\"4031\" data-col-size=\"sm\"\u003eSeasonal energy efficiency\u003c\/td\u003e  \u003ctd data-start=\"4031\" data-end=\"4039\" data-col-size=\"sm\"\u003e80%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4040\" data-end=\"4082\"\u003e  \u003ctd data-start=\"4040\" data-end=\"4072\" data-col-size=\"sm\"\u003eEfficiency at rated power\u003c\/td\u003e  \u003ctd data-start=\"4072\" data-end=\"4082\" data-col-size=\"sm\"\u003e82.9%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4083\" data-end=\"4125\"\u003e  \u003ctd data-start=\"4083\" data-end=\"4098\" data-col-size=\"sm\"\u003eboiler class\u003c\/td\u003e  \u003ctd data-start=\"4098\" data-end=\"4125\" data-col-size=\"sm\"\u003e5 (PN-EN 303-5:2021-09)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4126\" data-end=\"4179\"\u003e  \u003ctd data-start=\"4126\" data-end=\"4151\" data-col-size=\"sm\"\u003eRecommended fuel\u003c\/td\u003e  \u003ctd data-start=\"4151\" data-end=\"4179\" data-col-size=\"sm\"\u003eFirewood ≤25% moisture\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4180\" data-end=\"4212\"\u003e  \u003ctd data-start=\"4180\" data-end=\"4198\" data-col-size=\"sm\"\u003eExhaust gas temperature\u003c\/td\u003e  \u003ctd data-start=\"4198\" data-end=\"4212\" data-col-size=\"sm\"\u003e100–120 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4213\" data-end=\"4241\"\u003e  \u003ctd data-start=\"4213\" data-end=\"4229\" data-col-size=\"sm\"\u003eWater volume\u003c\/td\u003e  \u003ctd data-start=\"4229\" data-end=\"4241\" data-col-size=\"sm\"\u003e63 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4242\" data-end=\"4277\"\u003e  \u003ctd data-start=\"4242\" data-end=\"4263\" data-col-size=\"sm\"\u003eLoading chamber volume\u003c\/td\u003e  \u003ctd data-start=\"4263\" data-end=\"4277\" data-col-size=\"sm\"\u003eapprox. 42 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4278\" data-end=\"4302\"\u003e  \u003ctd data-start=\"4278\" data-end=\"4291\" data-col-size=\"sm\"\u003eBurning time\u003c\/td\u003e  \u003ctd data-start=\"4291\" data-end=\"4302\" data-col-size=\"sm\"\u003eapprox. 5 hours\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4303\" data-end=\"4337\"\u003e  \u003ctd data-start=\"4303\" data-end=\"4325\" data-col-size=\"sm\"\u003eFuel consumption\u003c\/td\u003e  \u003ctd data-start=\"4325\" data-end=\"4337\" data-col-size=\"sm\"\u003e2.8 kg\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4338\" data-end=\"4370\"\u003e  \u003ctd data-start=\"4338\" data-end=\"4359\" data-col-size=\"sm\"\u003eMax. operating pressure\u003c\/td\u003e  \u003ctd data-start=\"4359\" data-end=\"4370\" data-col-size=\"sm\"\u003e1.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4371\" data-end=\"4404\"\u003e  \u003ctd data-start=\"4371\" data-end=\"4392\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e  \u003ctd data-start=\"4392\" data-end=\"4404\" data-col-size=\"sm\"\u003e60–90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4405\" data-end=\"4443\"\u003e  \u003ctd data-start=\"4405\" data-end=\"4434\" data-col-size=\"sm\"\u003eMinimum return temperature\u003c\/td\u003e  \u003ctd data-start=\"4434\" data-end=\"4443\" data-col-size=\"sm\"\u003e55 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4444\" data-end=\"4478\"\u003e  \u003ctd data-start=\"4444\" data-end=\"4469\" data-col-size=\"sm\"\u003eFlow\/return connection\u003c\/td\u003e  \u003ctd data-start=\"4469\" data-end=\"4478\" data-col-size=\"sm\"\u003e40 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4479\" data-end=\"4496\"\u003e  \u003ctd data-start=\"4479\" data-end=\"4486\" data-col-size=\"sm\"\u003eHeight\u003c\/td\u003e  \u003ctd data-start=\"4486\" data-end=\"4496\" data-col-size=\"sm\"\u003e940 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4497\" data-end=\"4522\"\u003e  \u003ctd data-start=\"4497\" data-end=\"4512\" data-col-size=\"sm\"\u003eTotal width\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4512\" data-end=\"4522\"\u003e570 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4523\" data-end=\"4548\"\u003e  \u003ctd data-start=\"4523\" data-end=\"4537\" data-col-size=\"sm\"\u003eTotal length\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4537\" data-end=\"4548\"\u003e1070 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4549\" data-end=\"4573\"\u003e  \u003ctd data-start=\"4549\" data-end=\"4559\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4559\" data-end=\"4573\"\u003eapprox. 270 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4574\" data-end=\"4624\"\u003e  \u003ctd data-start=\"4574\" data-end=\"4606\" data-col-size=\"sm\"\u003eRequired chimney draft\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4606\" data-end=\"4624\"\u003e0.17–0.22 mbar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4625\" data-end=\"4658\"\u003e  \u003ctd data-start=\"4625\" data-end=\"4651\" data-col-size=\"sm\"\u003eMinimum chimney height\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4651\" data-end=\"4658\"\u003e7 m\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"4660\" data-end=\"4663\"\u003e  \u003ch1 data-start=\"4665\" data-end=\"4679\"\u003eScope of delivery\u003c\/h1\u003e  \u003cul data-start=\"4681\" data-end=\"4762\"\u003e  \u003cli data-start=\"4681\" data-end=\"4720\"\u003e  \u003cp data-start=\"4683\" data-end=\"4720\"\u003eMPM Wood Plus 10 wood gasification boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4721\" data-end=\"4744\"\u003e  \u003cp data-start=\"4723\" data-end=\"4744\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4745\" data-end=\"4762\"\u003e  \u003cp data-start=\"4747\" data-end=\"4762\"\u003eWarranty card\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"4764\" data-end=\"4767\"\u003e  \u003ch1 data-start=\"4769\" data-end=\"4807\"\u003eAccessories\/Recommendation (Cross-selling)\u003c\/h1\u003e  \u003cp data-start=\"4809\" data-end=\"4861\"\u003eRecommended accessories for standards-compliant operation:\u003c\/p\u003e  \u003cul data-start=\"4863\" data-end=\"5064\"\u003e  \u003cli data-start=\"4863\" data-end=\"4895\"\u003e  \u003cp data-start=\"4865\" data-end=\"4895\"\u003eBuffer tank 500–600 liters\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4896\" data-end=\"4948\"\u003e  \u003cp data-start=\"4898\" data-end=\"4948\"\u003eThermostatic anti-condensation valve (55 °C)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4949\" data-end=\"4975\"\u003e  \u003cp data-start=\"4951\" data-end=\"4975\"\u003eDBV-1 Thermostatic Valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4976\" data-end=\"5005\"\u003e  \u003cp data-start=\"4978\" data-end=\"5005\"\u003eSafety group 1.5 bar\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5006\" data-end=\"5031\"\u003e  \u003cp data-start=\"5008\" data-end=\"5031\"\u003eFour-way mixing valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5032\" data-end=\"5064\"\u003e  \u003cp data-start=\"5034\" data-end=\"5064\"\u003eDraft regulator for chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5066\" data-end=\"5126\"\u003eSuitable components can be found at:\u003cbr data-start=\"5104\" data-end=\"5107\"\u003e\u003ca data-start=\"5107\" data-end=\"5126\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/gemashop.de\"\u003ehttps:\/\/gemashop.de\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-eri7ssmm.svg#304883\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e  \u003chr data-start=\"5128\" data-end=\"5131\"\u003e  \u003ch1 data-start=\"5133\" data-end=\"5165\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h1\u003e  \u003cp data-start=\"5167\" data-end=\"5252\"\u003eInstallation must be carried out exclusively by a qualified specialist company.\u003c\/p\u003e  \u003cp data-start=\"5254\" data-end=\"5270\"\u003eKey points:\u003c\/p\u003e  \u003cul data-start=\"5272\" data-end=\"5474\"\u003e  \u003cli data-start=\"5272\" data-end=\"5324\"\u003e  \u003cp data-start=\"5274\" data-end=\"5324\"\u003eReturn temperature ≥ 55 °C is mandatory\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5325\" data-end=\"5359\"\u003e  \u003cp data-start=\"5327\" data-end=\"5359\"\u003eOperation only with buffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5360\" data-end=\"5406\"\u003e  \u003cp data-start=\"5362\" data-end=\"5406\"\u003eNo operation below 60 °C flow temperature\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5407\" data-end=\"5474\"\u003e  \u003cp data-start=\"5409\" data-end=\"5474\"\u003eDo not burn plastics or unsuitable fuels.\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5476\" data-end=\"5521\"\u003eFailure to comply will result in loss of warranty.\u003c\/p\u003e  \u003chr data-start=\"5523\" data-end=\"5526\"\u003e  \u003ch1 data-start=\"5528\" data-end=\"5533\"\u003eFAQ\u003c\/h1\u003e  \u003cp data-start=\"5535\" data-end=\"5637\"\u003e\u003cstrong data-start=\"5535\" data-end=\"5575\"\u003e1. Which fuels are permitted?\u003c\/strong\u003e\u003cbr data-start=\"5575\" data-end=\"5578\"\u003eFirewood with ≤25% moisture content according to PN-EN 303-5.\u003c\/p\u003e  \u003cp data-start=\"5639\" data-end=\"5730\"\u003e\u003cstrong data-start=\"5639\" data-end=\"5682\"\u003e2. Is a buffer storage tank required?\u003c\/strong\u003e\u003cbr data-start=\"5682\" data-end=\"5685\"\u003eYes, required. Recommended: 500–600 liters.\u003c\/p\u003e  \u003cp data-start=\"5732\" data-end=\"5871\"\u003e\u003cstrong data-start=\"5732\" data-end=\"5802\"\u003e3. Can the boiler be operated in a closed system?\u003c\/strong\u003e\u003cbr data-start=\"5802\" data-end=\"5805\"\u003eYes, with a diaphragm expansion vessel, safety valve and DBV protection.\u003c\/p\u003e  \u003cp data-start=\"5873\" data-end=\"5950\"\u003e\u003cstrong data-start=\"5873\" data-end=\"5930\"\u003e4. What minimum return temperature must be maintained?\u003c\/strong\u003e\u003cbr data-start=\"5930\" data-end=\"5933\"\u003eAt least 55 °C.\u003c\/p\u003e  \u003cp data-start=\"5952\" data-end=\"6012\"\u003e\u003cstrong data-start=\"5952\" data-end=\"5994\"\u003e5. What energy class does the device have?\u003c\/strong\u003e\u003cbr data-start=\"5994\" data-end=\"5997\"\u003eA+ with EEI 117.\u003c\/p\u003e  \u003cp data-start=\"6014\" data-end=\"6078\"\u003e\u003cstrong data-start=\"6014\" data-end=\"6068\"\u003e6. What is the efficiency at rated power?\u003c\/strong\u003e\u003cbr data-start=\"6068\" data-end=\"6071\"\u003e82.9%.\u003c\/p\u003e  \u003cp data-start=\"6080\" data-end=\"6161\"\u003e\u003cstrong data-start=\"6080\" data-end=\"6124\"\u003e7. Does the boiler comply with Ecodesign 2023?\u003c\/strong\u003e\u003cbr data-start=\"6124\" data-end=\"6127\"\u003eYes, according to EU Regulation 2015\/1189.\u003c\/p\u003e  \u003chr data-start=\"6163\" data-end=\"6166\"\u003e  \u003ch1 data-start=\"6168\" data-end=\"6175\"\u003eConclusion\u003c\/h1\u003e  \u003cp data-start=\"6177\" data-end=\"6361\"\u003eThe MPM Wood Plus 10 is a high-performance Class 5 wood gasification boiler with A+ efficiency and Ecodesign approval. Ideal for modern log-fired heating systems with buffer storage.\u003c\/p\u003e  \u003cp data-start=\"6363\" data-end=\"6409\"\u003eOrder now and heat efficiently with wood.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":54128450666844,"sku":"MPMWP10","price":2150.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-wood-plus-10-kw-holzvergaserkessel-a-klasse-5-o178-1580983.webp?v=1770692372"},{"product_id":"mpm-wood-plus-18-holzvergaserkessel-18kw","title":"MPM Wood Plus 18 wood gasification boiler 18 kW A+","description":"\u003cp data-start=\"972\" data-end=\"1402\"\u003eThe \u003cstrong data-start=\"976\" data-end=\"996\"\u003eMPM Wood Plus 18\u003c\/strong\u003e is a modern wood gasification boiler with a nominal output of 18 kW for heating single-family homes and smaller commercial units.\u003cbr data-start=\"1128\" data-end=\"1131\"\u003eThe log boiler meets the requirements of \u003cstrong data-start=\"1182\" data-end=\"1221\"\u003eEcodesign Regulation (EU) 2015\/1189\u003c\/strong\u003e as well as class 5 according to PN-EN 303-5 and achieves energy efficiency class A+.\u003cbr data-start=\"1297\" data-end=\"1300\"\u003eDesigned for operation with a buffer storage tank, it offers an efficient and low-emission wood heating system.\u003c\/p\u003e  \u003chr data-start=\"1404\" data-end=\"1407\"\u003e  \u003ch2 data-start=\"1409\" data-end=\"1433\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"1435\" data-end=\"1795\"\u003e⭐ 18 kW nominal power – ideal for single-family homes and smaller commercial properties\u003cbr data-start=\"1513\" data-end=\"1516\"\u003e⭐ Energy efficiency class A+ – EEI 119 for high seasonal efficiency\u003cbr data-start=\"1582\" data-end=\"1585\"\u003e⭐ Class 5 according to PN-EN 303-5 – low emissions and Ecodesign compliant\u003cbr data-start=\"1656\" data-end=\"1659\"\u003e⭐ Wood gasification technology – high efficiency and clean combustion\u003cbr data-start=\"1731\" data-end=\"1734\"\u003e⭐ Suitable for open and closed systems (max. 1.5 bar)\u003c\/p\u003e  \u003chr data-start=\"1797\" data-end=\"1800\"\u003e  \u003ch1 data-start=\"1802\" data-end=\"1823\"\u003eProduct description\u003c\/h1\u003e  \u003ch2 data-start=\"1825\" data-end=\"1855\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1857\" data-end=\"1939\"\u003eThe MPM Wood Plus 18 is a manually fed wood gasification boiler for heating:\u003c\/p\u003e  \u003cul data-start=\"1941\" data-end=\"2042\"\u003e  \u003cli data-start=\"1941\" data-end=\"1963\"\u003e  \u003cp data-start=\"1943\" data-end=\"1963\"\u003eSingle-family homes\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1964\" data-end=\"1980\"\u003e  \u003cp data-start=\"1966\" data-end=\"1980\"\u003eresidential buildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1981\" data-end=\"2001\"\u003e  \u003cp data-start=\"1983\" data-end=\"2001\"\u003ecommercial pavilions\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2002\" data-end=\"2017\"\u003e  \u003cp data-start=\"2004\" data-end=\"2017\"\u003eworkshops\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2018\" data-end=\"2042\"\u003e  \u003cp data-start=\"2020\" data-end=\"2042\"\u003ecatering establishments\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2044\" data-end=\"2214\"\u003eThe operation is carried out with \u003cstrong data-start=\"2068\" data-end=\"2099\"\u003eFirewood (moisture content ≤ 25%)\u003c\/strong\u003e.  The boiler is designed exclusively for operation at nominal output in conjunction with a buffer storage tank.\u003c\/p\u003e  \u003chr data-start=\"2216\" data-end=\"2219\"\u003e  \u003ch2 data-start=\"2221\" data-end=\"2242\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"2244\" data-end=\"2386\"\u003eCarburetor technology separates degassing and combustion into two chambers. This results in particularly clean and efficient combustion.\u003c\/p\u003e  \u003cp data-start=\"2388\" data-end=\"2639\"\u003eThe integrated ceramic burner with controlled primary and secondary air ensures stable flame guidance.\u003cbr data-start=\"2501\" data-end=\"2504\"\u003eThe large loading chamber (approx. 70 liters\/approx. 25 kg of wood) allows for convenient filling intervals with a burning time of up to 5 hours.\u003c\/p\u003e  \u003chr data-start=\"2641\" data-end=\"2644\"\u003e  \u003ch2 data-start=\"2646\" data-end=\"2670\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2672\" data-end=\"2750\"\u003eThe boiler is made of certified steel boiler sheet and features:\u003c\/p\u003e  \u003cul data-start=\"2752\" data-end=\"2970\"\u003e  \u003cli data-start=\"2752\" data-end=\"2776\"\u003e  \u003cp data-start=\"2754\" data-end=\"2776\"\u003eMetal-ceramic burner\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2777\" data-end=\"2828\"\u003e  \u003cp data-start=\"2779\" data-end=\"2828\"\u003eVertical flue gas ducts with turbulence unit\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2829\" data-end=\"2854\"\u003e  \u003cp data-start=\"2831\" data-end=\"2854\"\u003eMechanical train control\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2855\" data-end=\"2911\"\u003e  \u003cp data-start=\"2857\" data-end=\"2911\"\u003eConnection for thermostatic safety valve DBV-1\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2912\" data-end=\"2938\"\u003e  \u003cp data-start=\"2914\" data-end=\"2938\"\u003e40 mm mineral wool insulation\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2939\" data-end=\"2970\"\u003e  \u003cp data-start=\"2941\" data-end=\"2970\"\u003eThermometer in the upper area\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2972\" data-end=\"3063\"\u003eThe maximum operating temperature is 90 °C, the maximum permissible operating pressure is 1.5 bar.\u003c\/p\u003e  \u003chr data-start=\"3065\" data-end=\"3068\"\u003e  \u003ch2 data-start=\"3070\" data-end=\"3091\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"3093\" data-end=\"3231\"\u003eThe MPM Wood Plus 18 meets the requirements of \u003cstrong data-start=\"3144\" data-end=\"3183\"\u003eEcodesign Regulation (EU) 2015\/1189\u003c\/strong\u003e and possesses a valid certificate ED\/1202\/23.\u003c\/p\u003e  \u003cp data-start=\"3233\" data-end=\"3341\"\u003eSeasonal energy efficiency for space heating: 81%\u003cbr data-start=\"3277\" data-end=\"3280\"\u003eEnergy Efficiency Index (EEI): 119\u003cbr data-start=\"3312\" data-end=\"3315\"\u003eEnergy efficiency class: A+\u003c\/p\u003e  \u003cp data-start=\"3343\" data-end=\"3399\"\u003eEmissions at nominal output (firewood ≤ 25% moisture):\u003c\/p\u003e  \u003cul data-start=\"3401\" data-end=\"3472\"\u003e  \u003cli data-start=\"3401\" data-end=\"3417\"\u003e  \u003cp data-start=\"3403\" data-end=\"3417\"\u003ePM: 15 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3418\" data-end=\"3435\"\u003e  \u003cp data-start=\"3420\" data-end=\"3435\"\u003eOGC: 19 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3436\" data-end=\"3453\"\u003e  \u003cp data-start=\"3438\" data-end=\"3453\"\u003eCO: 401 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3454\" data-end=\"3472\"\u003e  \u003cp data-start=\"3456\" data-end=\"3472\"\u003eNOx: 145 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3474\" data-end=\"3477\"\u003e  \u003ch2 data-start=\"3479\" data-end=\"3516\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"3518\" data-end=\"3545\"\u003eOperation is possible in:\u003c\/p\u003e  \u003cul data-start=\"3547\" data-end=\"3672\"\u003e  \u003cli data-start=\"3547\" data-end=\"3571\"\u003e  \u003cp data-start=\"3549\" data-end=\"3571\"\u003eOpen heating systems\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3572\" data-end=\"3672\"\u003e  \u003cp data-start=\"3574\" data-end=\"3672\"\u003eClosed heating systems with diaphragm expansion vessel, safety valve and overheating protection\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3674\" data-end=\"3860\"\u003eA \u003cstrong data-start=\"3678\" data-end=\"3730\"\u003eBuffer storage tank with a volume of at least 800 liters\u003c\/strong\u003e is mandatory.\u003cbr data-start=\"3750\" data-end=\"3753\"\u003eThe return temperature must be at least 55 °C at all times to avoid low-temperature corrosion.\u003c\/p\u003e  \u003cp data-start=\"3862\" data-end=\"3898\"\u003eRecommended chimney requirements:\u003c\/p\u003e  \u003cul data-start=\"3900\" data-end=\"4014\"\u003e  \u003cli data-start=\"3900\" data-end=\"3950\"\u003e  \u003cp data-start=\"3902\" data-end=\"3950\"\u003eMinimum cross-sectional area: 180 × 180 mm or Ø 178 mm\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3951\" data-end=\"3971\"\u003e  \u003cp data-start=\"3953\" data-end=\"3971\"\u003eMinimum height: 8 m\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3972\" data-end=\"4014\"\u003e  \u003cp data-start=\"3974\" data-end=\"4014\"\u003eRequired draft: approx. 0.19–0.20 mbar\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"4016\" data-end=\"4019\"\u003e  \u003ch1 data-start=\"4021\" data-end=\"4039\"\u003eTechnical data\u003c\/h1\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"4041\" data-end=\"5053\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"4041\" data-end=\"4059\"\u003e  \u003ctr data-start=\"4041\" data-end=\"4059\"\u003e  \u003cth data-start=\"4041\" data-end=\"4051\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"4051\" data-end=\"4059\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"4080\" data-end=\"5053\"\u003e  \u003ctr data-start=\"4080\" data-end=\"4122\"\u003e  \u003ctd data-start=\"4080\" data-end=\"4093\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"4093\" data-end=\"4122\" data-col-size=\"sm\"\u003eMPM Project Marcin Nykiel\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4123\" data-end=\"4148\"\u003e  \u003ctd data-start=\"4123\" data-end=\"4132\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"4132\" data-end=\"4148\" data-col-size=\"sm\"\u003eWood Plus 18\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4149\" data-end=\"4184\"\u003e  \u003ctd data-start=\"4149\" data-end=\"4162\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"4162\" data-end=\"4184\" data-col-size=\"sm\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4185\" data-end=\"4209\"\u003e  \u003ctd data-start=\"4185\" data-end=\"4200\" data-col-size=\"sm\"\u003eRated power\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4200\" data-end=\"4209\"\u003e18 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4210\" data-end=\"4241\"\u003e  \u003ctd data-start=\"4210\" data-end=\"4235\" data-col-size=\"sm\"\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4235\" data-end=\"4241\"\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4242\" data-end=\"4279\"\u003e  \u003ctd data-start=\"4242\" data-end=\"4272\" data-col-size=\"sm\"\u003eEnergy Efficiency Index (EEI)\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4272\" data-end=\"4279\"\u003e119\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4280\" data-end=\"4322\"\u003e  \u003ctd data-start=\"4280\" data-end=\"4314\" data-col-size=\"sm\"\u003eSeasonal efficiency space heating\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4314\" data-end=\"4322\"\u003e81%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4323\" data-end=\"4372\"\u003e  \u003ctd data-start=\"4323\" data-end=\"4338\" data-col-size=\"sm\"\u003eboiler class\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4338\" data-end=\"4372\"\u003eClass 5 (PN-EN 303-5:2021-09)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4373\" data-end=\"4408\"\u003e  \u003ctd data-start=\"4373\" data-end=\"4400\" data-col-size=\"sm\"\u003eThermal efficiency\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4400\" data-end=\"4408\"\u003e89%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4409\" data-end=\"4451\"\u003e  \u003ctd data-start=\"4409\" data-end=\"4422\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4422\" data-end=\"4451\"\u003eFirewood ≤ 25% moisture\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4452\" data-end=\"4487\"\u003e  \u003ctd data-start=\"4452\" data-end=\"4473\" data-col-size=\"sm\"\u003eLoading chamber volume\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4473\" data-end=\"4487\"\u003eapprox. 70 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4488\" data-end=\"4519\"\u003e  \u003ctd data-start=\"4488\" data-end=\"4506\" data-col-size=\"sm\"\u003eFuel quantity\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4506\" data-end=\"4519\"\u003eapprox. 25 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4520\" data-end=\"4544\"\u003e  \u003ctd data-start=\"4520\" data-end=\"4533\" data-col-size=\"sm\"\u003eBurning time\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4533\" data-end=\"4544\"\u003eapprox. 5 hours\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4545\" data-end=\"4579\"\u003e  \u003ctd data-start=\"4545\" data-end=\"4567\" data-col-size=\"sm\"\u003eFuel consumption\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4567\" data-end=\"4579\"\u003e5.5 kg\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4580\" data-end=\"4613\"\u003e  \u003ctd data-start=\"4580\" data-end=\"4603\" data-col-size=\"sm\"\u003eWater volume boiler\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4603\" data-end=\"4613\"\u003e80 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4614\" data-end=\"4646\"\u003e  \u003ctd data-start=\"4614\" data-end=\"4635\" data-col-size=\"sm\"\u003eMax. operating pressure\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4635\" data-end=\"4646\"\u003e1.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4647\" data-end=\"4680\"\u003e  \u003ctd data-start=\"4647\" data-end=\"4668\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4668\" data-end=\"4680\"\u003e60–90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4681\" data-end=\"4720\"\u003e  \u003ctd data-start=\"4681\" data-end=\"4711\" data-col-size=\"sm\"\u003eMinimum return temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4711\" data-end=\"4720\"\u003e55 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4721\" data-end=\"4753\"\u003e  \u003ctd data-start=\"4721\" data-end=\"4739\" data-col-size=\"sm\"\u003eExhaust gas temperature\u003c\/td\u003e  \u003ctd data-start=\"4739\" data-end=\"4753\" data-col-size=\"sm\"\u003e125–140 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4754\" data-end=\"4785\"\u003e  \u003ctd data-start=\"4754\" data-end=\"4773\" data-col-size=\"sm\"\u003eExhaust gas mass flow\u003c\/td\u003e  \u003ctd data-start=\"4773\" data-end=\"4785\" data-col-size=\"sm\"\u003e10.8 g\/s\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4786\" data-end=\"4804\"\u003e  \u003ctd data-start=\"4786\" data-end=\"4793\" data-col-size=\"sm\"\u003eHeight\u003c\/td\u003e  \u003ctd data-start=\"4793\" data-end=\"4804\" data-col-size=\"sm\"\u003e1050 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4805\" data-end=\"4830\"\u003e  \u003ctd data-start=\"4805\" data-end=\"4820\" data-col-size=\"sm\"\u003eTotal width\u003c\/td\u003e  \u003ctd data-start=\"4820\" data-end=\"4830\" data-col-size=\"sm\"\u003e640 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4831\" data-end=\"4858\"\u003e  \u003ctd data-start=\"4831\" data-end=\"4848\" data-col-size=\"sm\"\u003eWide cases\u003c\/td\u003e  \u003ctd data-start=\"4848\" data-end=\"4858\" data-col-size=\"sm\"\u003e550 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4859\" data-end=\"4884\"\u003e  \u003ctd data-start=\"4859\" data-end=\"4873\" data-col-size=\"sm\"\u003eTotal length\u003c\/td\u003e  \u003ctd data-start=\"4873\" data-end=\"4884\" data-col-size=\"sm\"\u003e1070 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4885\" data-end=\"4920\"\u003e  \u003ctd data-start=\"4885\" data-end=\"4910\" data-col-size=\"sm\"\u003eLength without chimney\u003c\/td\u003e  \u003ctd data-start=\"4910\" data-end=\"4920\" data-col-size=\"sm\"\u003e870 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4921\" data-end=\"4945\"\u003e  \u003ctd data-start=\"4921\" data-end=\"4931\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e  \u003ctd data-start=\"4931\" data-end=\"4945\" data-col-size=\"sm\"\u003eapprox. 370 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4946\" data-end=\"4980\"\u003e  \u003ctd data-start=\"4946\" data-end=\"4971\" data-col-size=\"sm\"\u003eFlow\/return connection\u003c\/td\u003e  \u003ctd data-start=\"4971\" data-end=\"4980\" data-col-size=\"sm\"\u003e40 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4981\" data-end=\"5022\"\u003e  \u003ctd data-start=\"4981\" data-end=\"5009\" data-col-size=\"sm\"\u003eRecommended buffer volume\u003c\/td\u003e  \u003ctd data-start=\"5009\" data-end=\"5022\" data-col-size=\"sm\"\u003e800 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5023\" data-end=\"5053\"\u003e  \u003ctd data-start=\"5023\" data-end=\"5042\" data-col-size=\"sm\"\u003eCE marking\u003c\/td\u003e  \u003ctd data-start=\"5042\" data-end=\"5053\" data-col-size=\"sm\"\u003eCE 2023\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"5055\" data-end=\"5058\"\u003e  \u003ch2 data-start=\"5060\" data-end=\"5075\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"5077\" data-end=\"5153\"\u003e  \u003cli data-start=\"5077\" data-end=\"5108\"\u003e  \u003cp data-start=\"5079\" data-end=\"5108\"\u003eMPM Wood Plus 18 boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5109\" data-end=\"5132\"\u003e  \u003cp data-start=\"5111\" data-end=\"5132\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5133\" data-end=\"5153\"\u003e  \u003cp data-start=\"5135\" data-end=\"5153\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"5155\" data-end=\"5158\"\u003e  \u003ch2 data-start=\"5160\" data-end=\"5199\"\u003eAccessories\/Recommendation (Cross-selling)\u003c\/h2\u003e  \u003cp data-start=\"5201\" data-end=\"5241\"\u003eFor optimal operation, we recommend:\u003c\/p\u003e  \u003cul data-start=\"5243\" data-end=\"5434\"\u003e  \u003cli data-start=\"5243\" data-end=\"5274\"\u003e  \u003cp data-start=\"5245\" data-end=\"5274\"\u003eBuffer storage tank from 800 liters\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5275\" data-end=\"5321\"\u003e  \u003cp data-start=\"5277\" data-end=\"5321\"\u003eThermostatic anti-condensate valve 55 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5322\" data-end=\"5351\"\u003e  \u003cp data-start=\"5324\" data-end=\"5351\"\u003eSafety valve\/DBV-1\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5352\" data-end=\"5377\"\u003e  \u003cp data-start=\"5354\" data-end=\"5377\"\u003eFour-way mixing valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5378\" data-end=\"5406\"\u003e  \u003cp data-start=\"5380\" data-end=\"5406\"\u003eChimney draft regulator\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5407\" data-end=\"5434\"\u003e  \u003cp data-start=\"5409\" data-end=\"5434\"\u003eReturn flow boosting system\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5436\" data-end=\"5517\"\u003eSuitable components can be found in the wood heating section. \u0026amp; Accessories on gemashop.de.\u003c\/p\u003e  \u003chr data-start=\"5519\" data-end=\"5522\"\u003e  \u003ch2 data-start=\"5524\" data-end=\"5557\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"5559\" data-end=\"5656\"\u003eInstallation and commissioning must only be carried out by qualified specialists.\u003c\/p\u003e  \u003cp data-start=\"5658\" data-end=\"5829\"\u003eThe boiler may only be operated with suitable firewood.\u003cbr data-start=\"5721\" data-end=\"5724\"\u003eSustained returns below 55°C will lead to corrosion and void the warranty.\u003c\/p\u003e  \u003cp data-start=\"5831\" data-end=\"5903\"\u003eThe safety distance to flammable materials is at least 1 m.\u003c\/p\u003e  \u003chr data-start=\"5905\" data-end=\"5908\"\u003e  \u003ch1 data-start=\"5910\" data-end=\"5915\"\u003eFAQ\u003c\/h1\u003e  \u003cp data-start=\"5917\" data-end=\"6031\"\u003e\u003cstrong data-start=\"5917\" data-end=\"5961\"\u003e1.Which type of wood may be used?\u003c\/strong\u003e\u003cbr data-start=\"5961\" data-end=\"5964\"\u003eFirewood (hardwood) with a maximum moisture content of 25%, ideally 12–20%.\u003c\/p\u003e  \u003cp data-start=\"6033\" data-end=\"6133\"\u003e\u003cstrong data-start=\"6033\" data-end=\"6071\"\u003e2. Is a buffer storage tank mandatory?\u003c\/strong\u003e\u003cbr data-start=\"6071\" data-end=\"6074\"\u003eYes, a buffer volume of at least 800 liters is required.\u003c\/p\u003e  \u003cp data-start=\"6135\" data-end=\"6282\"\u003e\u003cstrong data-start=\"6135\" data-end=\"6205\"\u003e3. Can the boiler be operated in a closed system?\u003c\/strong\u003e\u003cbr data-start=\"6205\" data-end=\"6208\"\u003eYes, with safety valve, diaphragm expansion vessel and overheating protection.\u003c\/p\u003e  \u003cp data-start=\"6284\" data-end=\"6374\"\u003e\u003cstrong data-start=\"6284\" data-end=\"6333\"\u003e4. What energy efficiency class does the boiler have?\u003c\/strong\u003e\u003cbr data-start=\"6333\" data-end=\"6336\"\u003eEnergy efficiency class A+ with EEI 119.\u003c\/p\u003e  \u003cp data-start=\"6376\" data-end=\"6486\"\u003e\u003cstrong data-start=\"6376\" data-end=\"6425\"\u003e5. What emission class does the boiler meet?\u003c\/strong\u003e\u003cbr data-start=\"6425\" data-end=\"6428\"\u003eClass 5 according to PN-EN 303-5:2021-09 and Ecodesign 2015\/1189.\u003c\/p\u003e  \u003cp data-start=\"6488\" data-end=\"6546\"\u003e\u003cstrong data-start=\"6488\" data-end=\"6535\"\u003e6. What is the maximum operating pressure?\u003c\/strong\u003e\u003cbr data-start=\"6535\" data-end=\"6538\"\u003e1.5 bar.\u003c\/p\u003e  \u003cp data-start=\"6548\" data-end=\"6670\"\u003e\u003cstrong data-start=\"6548\" data-end=\"6605\"\u003e7. What is the minimum return temperature that must be maintained?\u003c\/strong\u003e\u003cbr data-start=\"6605\" data-end=\"6608\"\u003eAt least 55 °C to prevent low-temperature corrosion.\u003c\/p\u003e  \u003chr data-start=\"6672\" data-end=\"6675\"\u003e  \u003ch2 data-start=\"6677\" data-end=\"6685\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"6687\" data-end=\"6900\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe MPM Wood Plus 18 is a high-performance, Ecodesign-compliant wood gasification boiler with high efficiency and low emissions.\u003cbr data-start=\"6818\" data-end=\"6821\"\u003eA reliable solution for modern log-fired heating systems with buffer storage.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":54128521478492,"sku":"MPMWP18","price":2679.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-wood-plus-18-kw-holzvergaserkessel-a-klasse-5-o178-8766655.webp?v=1770692476"},{"product_id":"attack-slx-combi-pellet-20-kw-plus","title":"Attack SLX Combi Pellet 20 kW Plus","description":"\u003ch2\u003eAttack SLX combination boiler for wood and pellets - efficiency and versatility\u003c\/h2\u003e  \u003cp\u003eThe combination boiler \u003cstrong\u003eAttack SLX Combi\u003c\/strong\u003e It combines the advantages of a fully-fledged wood gasification boiler with the option of switching to fully automatic pellet operation. Whether you use wood, briquettes, or wood pellets as fuel, the boiler offers high convenience and an impressive efficiency of up to 91.6%. With its robust construction from special boiler steel and numerous innovative features, the\u003cstrong\u003e Attack SLX Combi\u003c\/strong\u003e A reliable and user-friendly companion for your heating needs.\u003c\/p\u003e  \u003ch3\u003eHigh efficiency and efficient heating\u003c\/h3\u003e  \u003cp\u003eThanks to the highly efficient tube heat exchanger with mechanical cleaning lever and advanced control, the Attack SLX achieves \u003cstrong\u003eCombination boiler \u003c\/strong\u003eOutstanding combustion efficiency. The integrated PID control continuously adjusts the fan speed, which, together with the fuzzy logic, ensures optimal energy utilization. The special turbulators in the heat exchanger slow down the exhaust gases and ensure maximum heat transfer to the heating water.\u003c\/p\u003e  \u003cp\u003eWith an impressive efficiency of over 91%, the boiler not only saves fuel costs but also represents an environmentally friendly heating solution, as wood and pellets are considered CO2-neutral fuels as biomass.\u003c\/p\u003e  \u003ch3\u003eFlexibility through wood and pellet operation\u003c\/h3\u003e  \u003cp\u003eThe \u003cstrong\u003eAttack SLX\u003c\/strong\u003e Combi is particularly impressive due to its flexibility. In wood gasification mode, you can easily operate the boiler with logs or briquettes. A large-capacity loading chamber with a capacity of up to 200 liters is available for this purpose, suitable for logs up to 690 mm in length.\u003c\/p\u003e  \u003cp\u003eFor the\u003cstrong\u003e Pellet operation is the boiler with a modern burner \u003c\/strong\u003eEquipped with a pellet feed system automatically supplied via an auger, the burner switches effortlessly between operating modes using a swivel mechanism. This allows you to choose between manual and fully automatic operation at any time, depending on your personal preference and needs.\u003c\/p\u003e  \u003ch3\u003eConvenient fully automatic operation with pellets\u003c\/h3\u003e  \u003cp\u003eIn pellet mode, the \u003cstrong\u003eAttack SLX Combi \u003c\/strong\u003ewith convenient, fully automatic operation. The burner ignites and extinguishes automatically to maintain the set temperature of the buffer tank. Burner cleaning is also fully automatic, significantly reducing maintenance.\u003c\/p\u003e  \u003cp\u003eWith optional control via a room thermostat, you can conveniently monitor and adjust boiler operation remotely without having to enter the boiler room. This increases user-friendliness and saves time.\u003c\/p\u003e  \u003ch3\u003eRobust construction for durability\u003c\/h3\u003e  \u003cp\u003eThe \u003cstrong\u003eAttack SLX combination boiler\u003c\/strong\u003e It is made from 6 mm thick, special boiler steel, ensuring a very long service life. The integrated cooling circuit safety device provides maximum operational safety and prevents overheating. With its well-designed and compact construction, the boiler is also space-saving and easy to install.\u003c\/p\u003e  \u003cp\u003eThe Attack SLX range is designed for durability and reliability, so you can benefit from an efficient heating experience for many years to come.\u003c\/p\u003e  \u003ch3\u003eInnovative control system for maximum efficiency\u003c\/h3\u003e  \u003cp\u003eThe boiler is equipped with a modern LCD display that clearly shows all important operating states and diagnostics. The control system allows for the regulation of two heating circuits as well as precise buffer tank control. Furthermore, the burner can be controlled either via a room thermostat or a temperature sensor.\u003c\/p\u003e  \u003cp\u003eThe innovative combination of PID control and fuzzy logic ensures continuous adjustment of combustion parameters to optimize heating performance and minimize losses. This allows the Attack SLX Combi to support not only efficient but also environmentally friendly combustion.\u003c\/p\u003e  \u003ch3\u003eEnvironmentally friendly and cost-saving\u003c\/h3\u003e  \u003cp\u003eWith its ability to flexibly combine wood and pellets, the Attack SLX Combi significantly reduces your heating costs per season. By using biomass as fuel, the boiler also contributes to environmental protection. Its low emissions and high energy efficiency ensure that the boiler meets stringent environmental standards.\u003c\/p\u003e  \u003cp\u003eAdditionally, the optional pellet hopper with a capacity of 500 liters offers extra convenience, as it allows for longer operating times without refilling.\u003c\/p\u003e  \u003ch3\u003eSummary\u003c\/h3\u003e  \u003cp\u003eThe \u003cstrong\u003eAttack SLX combination boiler for wood and pellets\u003c\/strong\u003e is a versatile and efficient heat generator that offers both high comfort and environmental friendliness. With its ability to switch between wood and pellet operation, it flexibly meets different heating requirements. The robust materials and innovative control technology make the \u003cstrong\u003eAttack SLX Combi \u003c\/strong\u003eto a sustainable and long-lasting solution for your heating needs.\u003c\/p\u003e  \u003cp\u003eIf you value efficiency, ease of use and environmental friendliness, the Attack SLX is the right choice.\u003cstrong\u003e Combination boiler\u003c\/strong\u003e The ideal choice for your home or investment.\u003c\/p\u003e  \u003ch3\u003eAdvantages\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eSimple bridge\u003cstrong\u003eEnergy metabolism – \u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan dir=\"auto\"\u003eWood\/Pellets\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eFully automatic firing process\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eAutomatic burner cleaning\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eHigh combustion efficiency \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e92%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eWide range of performance \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e20, 25, 30, 35 kW\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eDry coating – protection against tar\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eLong burning time \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003efrom 8 to 12 hours\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eLarge cargo space up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e200 l\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e\/\u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e650 mm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan\u003e\u003cspan dir=\"auto\"\u003eFireproof concrete molded parts, resistant to temperatures up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e1350 °C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003e\u003cspan dir=\"auto\"\u003eTechnical basic data\u003c\/span\u003e\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eNominal heat output: \u003cstrong\u003eWood 25 kW\/Pellets 30 kW\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eLoading chamber volume: \u003cstrong\u003e200 L\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eFilling opening: \u003cstrong\u003e235 x 445\u003c\/strong\u003e mm\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eChimney flue: \u003cstrong\u003e23 PA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eBoiler height: \u003cstrong\u003e1,472 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eBoiler width: \u003cstrong\u003e703 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eBoiler depth with burner: \u003cstrong\u003e1,650 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eBoiler depth without burner: \u003cstrong\u003e1,350 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eSmoke vent height: \u003cstrong\u003e985 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan dir=\"auto\"\u003eFlue pipe connection: \u003cstrong\u003e150 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eScope of delivery\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eAttack \u003cstrong\u003ePellet combination boiler 20 kW\u003c\/strong\u003e  \u003c\/li\u003e  \u003cli\u003ePellet container \u0026amp; auger\u003c\/li\u003e  \u003cli\u003eAssembly \u0026amp; User manual\u003c\/li\u003e  \u003c\/ul\u003e  \u003cstyle type=\"text\/css\"\u003e\n\ttable.tableizer-table {\n\t\tfont-size: 12px;\n\t\tborder: 1px solid #CCC; \n\t\tfont-family: Arial, Helvetica, sans-serif;\n\t} \n\t.tableizer-table td {\n\t\tpadding: 4px;\n\t\tmargin: 3px;\n\t\tborder: 1px solid #CCC;\n\t}\n\t.tableizer-table th {\n\t\tbackground-color: #104E8B; \n\t\tcolor: #FFF;\n\t\tfont-weight: bold;\n\t}\n\u003c\/style\u003e","brand":"Gema GmbH","offers":[{"title":"Default Title","offer_id":56129292992860,"sku":"20SLXCP+","price":7961.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Kombinovany_kotol_ATTACK_SLX_COMBI_PELLET_s_akumulacnou_nadrzou.webp?v=1774511114"},{"product_id":"mpm-caldo-s-i-18-kw-holzvergaserkessel","title":"MPM Caldo S-I 18 kW wood gasification boiler logs","description":"\u003cp data-start=\"694\" data-end=\"1035\"\u003eThe \u003cstrong data-start=\"698\" data-end=\"718\"\u003eMPM Caldo SI 18\u003c\/strong\u003e is a modern \u003cstrong data-start=\"736\" data-end=\"786\"\u003eWood gasification boiler with 18 kW nominal heat output\u003c\/strong\u003e For efficient heating of residential buildings. The boiler is designed for operation with \u003cstrong data-start=\"869\" data-end=\"883\"\u003efirewood\u003c\/strong\u003e designed to meet the \u003cstrong data-start=\"907\" data-end=\"934\"\u003eEcodesign requirements\u003c\/strong\u003e and reaches the \u003cstrong data-start=\"952\" data-end=\"981\"\u003eEnergy efficiency class A+\u003c\/strong\u003e.  The operation takes place \u003cstrong data-start=\"1003\" data-end=\"1034\"\u003eBuffer storage is mandatory\u003c\/strong\u003e.\u003c\/p\u003e  \u003chr data-start=\"1037\" data-end=\"1040\"\u003e  \u003ch2 data-start=\"1042\" data-end=\"1068\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"1070\" data-end=\"1494\"\u003e⭐  \u003cstrong data-start=\"1072\" data-end=\"1100\"\u003eEfficient wood gasification\u003c\/strong\u003e – High efficiency with clean combustion\u003cbr data-start=\"1146\" data-end=\"1149\"\u003e⭐  \u003cstrong data-start=\"1151\" data-end=\"1184\"\u003eEcodesign \u0026amp; Class 5 compliant\u003c\/strong\u003e – Complies with EU requirements according to Regulation (EU) 2015\/1189\u003cbr data-start=\"1238\" data-end=\"1241\"\u003e⭐  \u003cstrong data-start=\"1243\" data-end=\"1265\"\u003e18 kW heating output\u003c\/strong\u003e – Suitable for single-family homes and smaller commercial properties\u003cbr data-start=\"1326\" data-end=\"1329\"\u003e⭐  \u003cstrong data-start=\"1331\" data-end=\"1370\"\u003eManual loading with firewood\u003c\/strong\u003e – Independent of fossil fuels\u003cbr data-start=\"1405\" data-end=\"1408\"\u003e⭐  \u003cstrong data-start=\"1410\" data-end=\"1447\"\u003eMandatory operation with buffer storage\u003c\/strong\u003e – Optimal efficiency and longer service life\u003c\/p\u003e  \u003chr data-start=\"1496\" data-end=\"1499\"\u003e  \u003ch2 data-start=\"1501\" data-end=\"1531\"\u003eDetailed description\u003c\/h2\u003e  \u003ch3 data-start=\"1533\" data-end=\"1566\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h3\u003e  \u003cp data-start=\"1567\" data-end=\"1874\"\u003eThe MPM Caldo SI 18 is suitable for \u003cstrong data-start=\"1604\" data-end=\"1690\"\u003eSingle-family homes, multi-family homes, and smaller commercial and workshop buildings\u003c\/strong\u003e.  It is designed for use in open or closed heating systems and can also be used for hot water preparation in conjunction with a suitable heat exchanger.\u003c\/p\u003e  \u003ch3 data-start=\"1876\" data-end=\"1900\"\u003eEveryday benefits\u003c\/h3\u003e  \u003cp data-start=\"1901\" data-end=\"2155\"\u003eThanks to wood gasification technology, the fuel is used particularly efficiently. In combination with a buffer storage tank, this allows for even greater efficiency. \u003cstrong data-start=\"2037\" data-end=\"2062\"\u003elong burning intervals\u003c\/strong\u003e,  a \u003cstrong data-start=\"2068\" data-end=\"2097\"\u003econsistent heating operation\u003c\/strong\u003e and a \u003cstrong data-start=\"2107\" data-end=\"2145\"\u003eReduction of fuel consumption\u003c\/strong\u003e achieve.\u003c\/p\u003e  \u003ch3 data-start=\"2157\" data-end=\"2184\"\u003eTechnology \u0026amp; equipment\u003c\/h3\u003e  \u003cp data-start=\"2185\" data-end=\"2484\"\u003eThe boiler is out \u003cstrong data-start=\"2204\" data-end=\"2243\"\u003ecertified boiler steel (P265GH)\u003c\/strong\u003e manufactured and features a \u003cstrong data-start=\"2276\" data-end=\"2302\"\u003etwo-chamber design\u003c\/strong\u003e with separate gasification and combustion chambers. Primary and secondary air supply is manually adjustable. Standard features include a \u003cstrong data-start=\"2427\" data-end=\"2471\"\u003ethermal relief valve (cooling coil)\u003c\/strong\u003e prepared.\u003c\/p\u003e  \u003ch3 data-start=\"2486\" data-end=\"2510\"\u003eEfficiency \u0026amp; Environment\u003c\/h3\u003e  \u003cp data-start=\"2511\" data-end=\"2735\"\u003eWith a \u003cstrong data-start=\"2521\" data-end=\"2561\"\u003eseasonal energy efficiency of 80%\u003c\/strong\u003e and the \u003cstrong data-start=\"2570\" data-end=\"2599\"\u003eEnergy efficiency class A+\u003c\/strong\u003e The boiler meets current Ecodesign requirements. Its emission levels are within the permissible limits according to EU regulations.\u003c\/p\u003e  \u003ch3 data-start=\"2737\" data-end=\"2777\"\u003ecompatibility \u0026amp; System integration\u003c\/h3\u003e  \u003cp data-start=\"2778\" data-end=\"3050\"\u003eThe company is \u003cstrong data-start=\"2794\" data-end=\"2852\"\u003eonly in conjunction with a buffer storage tank ≥ 800 liters\u003c\/strong\u003e permissible. For safe operation, a \u003cstrong data-start=\"2897\" data-end=\"2938\"\u003eReturn temperature increase to at least 55 °C\u003c\/strong\u003e required. The boiler can be operated with various control systems (e.g. ecoMAX, Vera Bord, IE-72v5).\u003c\/p\u003e  \u003chr data-start=\"3052\" data-end=\"3055\"\u003e  \u003ch2 data-start=\"3057\" data-end=\"3078\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3080\" data-end=\"3976\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3080\" data-end=\"3098\"\u003e  \u003ctr data-start=\"3080\" data-end=\"3098\"\u003e  \u003cth data-start=\"3080\" data-end=\"3090\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3090\" data-end=\"3098\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3116\" data-end=\"3976\"\u003e  \u003ctr data-start=\"3116\" data-end=\"3158\"\u003e  \u003ctd data-start=\"3116\" data-end=\"3129\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3129\" data-end=\"3158\"\u003eMPM Project Marcin Nykiel\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3159\" data-end=\"3184\"\u003e  \u003ctd data-start=\"3159\" data-end=\"3168\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3168\" data-end=\"3184\"\u003eCaldo SI 18\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3185\" data-end=\"3220\"\u003e  \u003ctd data-start=\"3185\" data-end=\"3198\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3198\" data-end=\"3220\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3221\" data-end=\"3250\"\u003e  \u003ctd data-start=\"3221\" data-end=\"3241\" data-col-size=\"sm\"\u003eNominal heat output\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3241\" data-end=\"3250\"\u003e18 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3251\" data-end=\"3283\"\u003e  \u003ctd data-start=\"3251\" data-end=\"3272\" data-col-size=\"sm\"\u003eGenerated useful heat\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3272\" data-end=\"3283\"\u003e18.6 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3284\" data-end=\"3326\"\u003e  \u003ctd data-start=\"3284\" data-end=\"3316\" data-col-size=\"sm\"\u003eEfficiency at rated power\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3316\" data-end=\"3326\"\u003e83.3%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3327\" data-end=\"3364\"\u003e  \u003ctd data-start=\"3327\" data-end=\"3356\" data-col-size=\"sm\"\u003eSeasonal energy efficiency\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3356\" data-end=\"3364\"\u003e80%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3365\" data-end=\"3396\"\u003e  \u003ctd data-start=\"3365\" data-end=\"3390\" data-col-size=\"sm\"\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3390\" data-end=\"3396\"\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3397\" data-end=\"3434\"\u003e  \u003ctd data-start=\"3397\" data-end=\"3427\" data-col-size=\"sm\"\u003eEnergy Efficiency Index (EEI)\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3427\" data-end=\"3434\"\u003e117\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3435\" data-end=\"3489\"\u003e  \u003ctd data-start=\"3435\" data-end=\"3448\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3448\" data-end=\"3489\"\u003eFirewood (hardwood, moisture content ≤ 25%)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3490\" data-end=\"3534\"\u003e  \u003ctd data-start=\"3490\" data-end=\"3505\" data-col-size=\"sm\"\u003eboiler class\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3505\" data-end=\"3534\"\u003e5 (PN-EN 303-5 + A1:2023)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3535\" data-end=\"3584\"\u003e  \u003ctd data-start=\"3535\" data-end=\"3571\" data-col-size=\"sm\"\u003eRecommended buffer storage volume\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3571\" data-end=\"3584\"\u003e800 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3585\" data-end=\"3620\"\u003e  \u003ctd data-start=\"3585\" data-end=\"3611\" data-col-size=\"sm\"\u003eMax.Operating temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3611\" data-end=\"3620\"\u003e90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3621\" data-end=\"3659\"\u003e  \u003ctd data-start=\"3621\" data-end=\"3650\" data-col-size=\"sm\"\u003eMinimum return temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3650\" data-end=\"3659\"\u003e55 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3660\" data-end=\"3690\"\u003e  \u003ctd data-start=\"3660\" data-end=\"3681\" data-col-size=\"sm\"\u003eMax. operating pressure\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3681\" data-end=\"3690\"\u003e3 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3691\" data-end=\"3740\"\u003e  \u003ctd data-start=\"3691\" data-end=\"3726\" data-col-size=\"sm\"\u003eExhaust gas temperature at rated power\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3726\" data-end=\"3740\"\u003eapprox. 130 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3741\" data-end=\"3775\"\u003e  \u003ctd data-start=\"3741\" data-end=\"3763\" data-col-size=\"sm\"\u003eBoiler water volume\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3763\" data-end=\"3775\"\u003e85 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3776\" data-end=\"3800\"\u003e  \u003ctd data-start=\"3776\" data-end=\"3786\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3786\" data-end=\"3800\"\u003eapprox. 450 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3801\" data-end=\"3834\"\u003e  \u003ctd data-start=\"3801\" data-end=\"3826\" data-col-size=\"sm\"\u003eFlow\/return connection\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3826\" data-end=\"3834\"\u003e6\/4\"\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3835\" data-end=\"3870\"\u003e  \u003ctd data-start=\"3835\" data-end=\"3853\" data-col-size=\"sm\"\u003epower supply\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3853\" data-end=\"3870\"\u003e230 V\/50 Hz\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3871\" data-end=\"3920\"\u003e  \u003ctd data-start=\"3871\" data-end=\"3903\" data-col-size=\"sm\"\u003eElectrical power consumption\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3903\" data-end=\"3920\"\u003emax. 0.023 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3921\" data-end=\"3976\"\u003e  \u003ctd data-start=\"3921\" data-end=\"3944\" data-col-size=\"sm\"\u003eStandards \u0026amp; Guidelines\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3944\" data-end=\"3976\"\u003eCE, Ecodesign (EU) 2015\/1189\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"3978\" data-end=\"3981\"\u003e  \u003ch2 data-start=\"3983\" data-end=\"4000\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"4002\" data-end=\"4090\"\u003e  \u003cli data-start=\"4002\" data-end=\"4045\"\u003e  \u003cp data-start=\"4004\" data-end=\"4045\"\u003ewood gasification boiler \u003cstrong data-start=\"4023\" data-end=\"4043\"\u003eMPM Caldo SI 18\u003c\/strong\u003e\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4046\" data-end=\"4069\"\u003e  \u003cp data-start=\"4048\" data-end=\"4069\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4070\" data-end=\"4090\"\u003e  \u003cp data-start=\"4072\" data-end=\"4090\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"4092\" data-end=\"4095\"\u003e  \u003ch2 data-start=\"4097\" data-end=\"4122\"\u003eAccessories\/Recommendation\u003c\/h2\u003e  \u003cp data-start=\"4124\" data-end=\"4188\"\u003eFor compliant and efficient operation, we recommend:\u003c\/p\u003e  \u003cul data-start=\"4190\" data-end=\"4389\"\u003e  \u003cli data-start=\"4190\" data-end=\"4224\"\u003e  \u003cp data-start=\"4192\" data-end=\"4224\"\u003e\u003cstrong data-start=\"4192\" data-end=\"4222\"\u003eBuffer storage tank ≥ 800 liters\u003c\/strong\u003e\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4225\" data-end=\"4264\"\u003e  \u003cp data-start=\"4227\" data-end=\"4264\"\u003e\u003cstrong data-start=\"4227\" data-end=\"4262\"\u003eReturn flow booster group (55 °C)\u003c\/strong\u003e\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4265\" data-end=\"4313\"\u003e  \u003cp data-start=\"4267\" data-end=\"4313\"\u003e\u003cstrong data-start=\"4267\" data-end=\"4311\"\u003eThermal relief valve (BVTS valve)\u003c\/strong\u003e\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4314\" data-end=\"4347\"\u003e  \u003cp data-start=\"4316\" data-end=\"4347\"\u003e\u003cstrong data-start=\"4316\" data-end=\"4345\"\u003eHeating control \u0026amp; sensor\u003c\/strong\u003e\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4348\" data-end=\"4389\"\u003e  \u003cp data-start=\"4350\" data-end=\"4389\"\u003e\u003cstrong data-start=\"4350\" data-end=\"4387\"\u003eSecurity group \u0026amp; Connection sets\u003c\/strong\u003e\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"4391\" data-end=\"4522\"\u003eYou can find suitable components in the categories \u003cem data-start=\"4441\" data-end=\"4457\"\u003eBuffer storage\u003c\/em\u003e, \u003cem data-start=\"4459\" data-end=\"4479\"\u003eSecurity groups\u003c\/em\u003e and \u003cem data-start=\"4484\" data-end=\"4501\"\u003eHeating accessories\u003c\/em\u003e on \u003cstrong data-start=\"4506\" data-end=\"4521\"\u003egemashop.de\u003c\/strong\u003e.\u003c\/p\u003e  \u003chr data-start=\"4524\" data-end=\"4527\"\u003e  \u003ch2 data-start=\"4529\" data-end=\"4564\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"4566\" data-end=\"4906\"\u003eThe \u003cstrong data-start=\"4570\" data-end=\"4664\"\u003eInstallation and commissioning may only be carried out by a qualified specialist company.\u003c\/strong\u003e take place.\u003cbr data-start=\"4674\" data-end=\"4677\"\u003eThe company is \u003cstrong data-start=\"4693\" data-end=\"4719\"\u003eonly with buffer storage\u003c\/strong\u003e permissible. A return temperature below 55 °C leads to corrosion and to \u003cstrong data-start=\"4793\" data-end=\"4817\"\u003eLoss of warranty\u003c\/strong\u003e.  Only fuels approved by the manufacturer may be used.\u003c\/p\u003e  \u003chr data-start=\"4908\" data-end=\"4911\"\u003e  \u003ch2 data-start=\"4913\" data-end=\"4921\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"4923\" data-end=\"5046\"\u003e\u003cstrong data-start=\"4923\" data-end=\"4962\"\u003e1. Which fuel is permitted?\u003c\/strong\u003e\u003cbr data-start=\"4962\" data-end=\"4965\"\u003eOnly firewood (hardwood) with a residual moisture content ≤ 25% is permitted.\u003c\/p\u003e  \u003cp data-start=\"5048\" data-end=\"5173\"\u003e\u003cstrong data-start=\"5048\" data-end=\"5086\"\u003e2. Is a buffer storage tank mandatory?\u003c\/strong\u003e\u003cbr data-start=\"5086\" data-end=\"5089\"\u003eYes, operation is only permitted with a buffer storage tank of at least 800 liters.\u003c\/p\u003e  \u003cp data-start=\"5175\" data-end=\"5308\"\u003e\u003cstrong data-start=\"5175\" data-end=\"5226\"\u003e3. Does the boiler comply with the Ecodesign Directive?\u003c\/strong\u003e\u003cbr data-start=\"5226\" data-end=\"5229\"\u003eYes, the MPM Caldo SI 18 meets the requirements of EU Regulation 2015\/1189.\u003c\/p\u003e  \u003cp data-start=\"5310\" data-end=\"5450\"\u003e\u003cstrong data-start=\"5310\" data-end=\"5360\"\u003e4. For which buildings is the boiler suitable?\u003c\/strong\u003e\u003cbr data-start=\"5360\" data-end=\"5363\"\u003eFor single-family homes, smaller multi-family homes, as well as commercial and workshop buildings.\u003c\/p\u003e  \u003cp data-start=\"5452\" data-end=\"5590\"\u003e\u003cstrong data-start=\"5452\" data-end=\"5522\"\u003e5. Can the boiler be operated in a closed system?\u003c\/strong\u003e\u003cbr data-start=\"5522\" data-end=\"5525\"\u003eYes, provided that the safety requirements according to the standard are met.\u003c\/p\u003e  \u003cp data-start=\"5592\" data-end=\"5710\"\u003e\u003cstrong data-start=\"5592\" data-end=\"5644\"\u003e6. What energy efficiency class does the boiler have?\u003c\/strong\u003e\u003cbr data-start=\"5644\" data-end=\"5647\"\u003eThe boiler is in energy efficiency class \u003cstrong data-start=\"5692\" data-end=\"5698\"\u003eA+\u003c\/strong\u003e classified.\u003c\/p\u003e  \u003chr data-start=\"5712\" data-end=\"5715\"\u003e  \u003ch2 data-start=\"5717\" data-end=\"5727\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"5729\" data-end=\"5956\"\u003eThe \u003cstrong data-start=\"5733\" data-end=\"5753\"\u003eMPM Caldo SI 18\u003c\/strong\u003e is a high-performance, ecodesign-compliant wood gasification boiler for all those who rely on \u003cstrong data-start=\"5837\" data-end=\"5898\"\u003eefficient and independent heat supply with firewood\u003c\/strong\u003e Set it. Order now and sustainably reduce your heating costs.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":56649406349660,"sku":"MPMC18","price":3665.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-caldo-s-i-25-kw-holzvergaserkessel-a-ecodesign-klasse-5-holzvergaserkessel-2033103.webp?v=1770944052"},{"product_id":"mpm-wood-plus-14-holzvergaserkessel-14kw","title":"MPM Wood Plus 14 wood gasification boiler 14 kW log boiler","description":"\u003cp data-start=\"937\" data-end=\"1293\"\u003eThe MPM Wood Plus 14 is a modern wood gasification boiler with a nominal output of 14 kW for the efficient combustion of logs. It meets the requirements of Class 5 according to PN-EN 303-5:2021-09 as well as the Ecodesign Directive and achieves energy efficiency class A+.\u003cbr data-start=\"1206\" data-end=\"1209\"\u003eIdeal for single-family homes and smaller commercial units with buffer storage operation.\u003c\/p\u003e  \u003chr data-start=\"1295\" data-end=\"1298\"\u003e  \u003ch2 data-start=\"1300\" data-end=\"1324\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"1326\" data-end=\"1721\"\u003e⭐ Wood gasification technology – efficient, clean combustion of firewood\u003cbr data-start=\"1402\" data-end=\"1405\"\u003e⭐ Energy efficiency class A+ (EEI 118) – reduced emissions and high efficiency\u003cbr data-start=\"1489\" data-end=\"1492\"\u003e⭐ Class 5 according to PN-EN 303-5:2021-09 – meets current environmental requirements\u003cbr data-start=\"1566\" data-end=\"1569\"\u003e⭐ Large filling chamber (~52 dm³) – comfortable burning time of up to approx. 5 hours\u003cbr data-start=\"1640\" data-end=\"1643\"\u003e⭐ Operation possible in open or closed systems – flexibly deployable\u003c\/p\u003e  \u003chr data-start=\"1723\" data-end=\"1726\"\u003e  \u003ch1 data-start=\"1728\" data-end=\"1765\"\u003eMPM Wood Plus 14 wood gasification boiler\u003c\/h1\u003e  \u003ch2 data-start=\"1767\" data-end=\"1797\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1799\" data-end=\"2025\"\u003eThe MPM Wood Plus 14 is a water-bearing wood gasification boiler with manual feeding for operation with logs (moisture content ≤ 25%). It is designed for open and closed heating systems and is particularly suitable for:\u003c\/p\u003e  \u003cul data-start=\"2027\" data-end=\"2135\"\u003e  \u003cli data-start=\"2027\" data-end=\"2048\"\u003e  \u003cp data-start=\"2029\" data-end=\"2048\"\u003eSingle-family homes\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2049\" data-end=\"2073\"\u003e  \u003cp data-start=\"2051\" data-end=\"2073\"\u003esmaller residential properties\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2074\" data-end=\"2135\"\u003e  \u003cp data-start=\"2076\" data-end=\"2135\"\u003eWorkshops, commercial pavilions and service businesses\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2137\" data-end=\"2229\"\u003eThe maximum flow temperature is 90 °C at a permissible operating pressure of 1.5 bar.\u003c\/p\u003e  \u003cp data-start=\"2231\" data-end=\"2436\"\u003eThe unit is designed for use exclusively with a buffer storage tank. According to the product data sheet, a buffer volume of at least 800 liters is required; 300–800 liters are technically recommended.\u003c\/p\u003e  \u003chr data-start=\"2438\" data-end=\"2441\"\u003e  \u003ch2 data-start=\"2443\" data-end=\"2464\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"2466\" data-end=\"2689\"\u003eThe wood gasification principle involves combustion in two separate chambers: First, the wood is degassed, then the resulting wood gases are combusted in a ceramic combustion chamber. This ensures:\u003c\/p\u003e  \u003cul data-start=\"2691\" data-end=\"2790\"\u003e  \u003cli data-start=\"2691\" data-end=\"2714\"\u003e  \u003cp data-start=\"2693\" data-end=\"2714\"\u003estable combustion\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2715\" data-end=\"2739\"\u003e  \u003cp data-start=\"2717\" data-end=\"2739\"\u003ehigh energy yield\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2740\" data-end=\"2765\"\u003e  \u003cp data-start=\"2742\" data-end=\"2765\"\u003ereduced emissions\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2766\" data-end=\"2790\"\u003e  \u003cp data-start=\"2768\" data-end=\"2790\"\u003eclean exhaust gas routing\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2792\" data-end=\"2954\"\u003eThe large loading chamber with a volume of approximately 52 dm³ allows for a burning time of up to approximately 5 hours with an average fuel consumption of approximately 3.5 kg\/h.\u003c\/p\u003e  \u003chr data-start=\"2956\" data-end=\"2959\"\u003e  \u003ch2 data-start=\"2961\" data-end=\"2985\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2987\" data-end=\"3071\"\u003eThe boiler consists of welded steel boiler sheet with 40 mm mineral wool insulation.\u003c\/p\u003e  \u003cp data-start=\"3073\" data-end=\"3094\"\u003eKey features:\u003c\/p\u003e  \u003cul data-start=\"3096\" data-end=\"3368\"\u003e  \u003cli data-start=\"3096\" data-end=\"3122\"\u003e  \u003cp data-start=\"3098\" data-end=\"3122\"\u003eMetal-ceramic burner\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3123\" data-end=\"3147\"\u003e  \u003cp data-start=\"3125\" data-end=\"3147\"\u003eMovable cast iron grate\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3148\" data-end=\"3196\"\u003e  \u003cp data-start=\"3150\" data-end=\"3196\"\u003eVertical convection channels with swirl unit\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3197\" data-end=\"3224\"\u003e  \u003cp data-start=\"3199\" data-end=\"3224\"\u003eMechanical train control\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3225\" data-end=\"3264\"\u003e  \u003cp data-start=\"3227\" data-end=\"3264\"\u003eThermometer in the upper boiler area\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3265\" data-end=\"3316\"\u003e  \u003cp data-start=\"3267\" data-end=\"3316\"\u003eConnection sleeves for flow and return (38.1 mm)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3317\" data-end=\"3342\"\u003e  \u003cp data-start=\"3319\" data-end=\"3342\"\u003eDBV-1 valve connection\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3343\" data-end=\"3368\"\u003e  \u003cp data-start=\"3345\" data-end=\"3368\"\u003eexhaust connection at the rear\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3370\" data-end=\"3481\"\u003eThe required chimney draft is approximately 0.18–0.21 mbar.\u003cbr data-start=\"3430\" data-end=\"3433\"\u003eRecommended return temperature: at least 55 °C.\u003c\/p\u003e  \u003chr data-start=\"3483\" data-end=\"3486\"\u003e  \u003ch2 data-start=\"3488\" data-end=\"3509\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"3511\" data-end=\"3611\"\u003eThe MPM Wood Plus 14 meets the requirements of EU Regulation 2015\/1189 (Ecodesign) and achieves:\u003c\/p\u003e  \u003cul data-start=\"3613\" data-end=\"3763\"\u003e  \u003cli data-start=\"3613\" data-end=\"3649\"\u003e  \u003cp data-start=\"3615\" data-end=\"3649\"\u003eSeasonal energy efficiency: 81%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3650\" data-end=\"3680\"\u003e  \u003cp data-start=\"3652\" data-end=\"3680\"\u003eEnergy efficiency class: A+\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3681\" data-end=\"3717\"\u003e  \u003cp data-start=\"3683\" data-end=\"3717\"\u003eEnergy Efficiency Index (EEI): 118\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3718\" data-end=\"3763\"\u003e  \u003cp data-start=\"3720\" data-end=\"3763\"\u003eEfficiency at rated power: 83.7%\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3765\" data-end=\"3810\"\u003eEmission values ​​for firewood ≤ 25% moisture content:\u003c\/p\u003e  \u003cul data-start=\"3812\" data-end=\"3891\"\u003e  \u003cli data-start=\"3812\" data-end=\"3836\"\u003e  \u003cp data-start=\"3814\" data-end=\"3836\"\u003eDust (PM): 13 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3837\" data-end=\"3854\"\u003e  \u003cp data-start=\"3839\" data-end=\"3854\"\u003eOGC: 16 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3855\" data-end=\"3872\"\u003e  \u003cp data-start=\"3857\" data-end=\"3872\"\u003eCO: 500 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3873\" data-end=\"3891\"\u003e  \u003cp data-start=\"3875\" data-end=\"3891\"\u003eNOx: 146 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3893\" data-end=\"3986\"\u003eThe boiler complies with class 5 according to PN-EN 303-5:2021-09 and bears the CE mark (2023).\u003c\/p\u003e  \u003chr data-start=\"3988\" data-end=\"3991\"\u003e  \u003ch2 data-start=\"3993\" data-end=\"4030\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"4032\" data-end=\"4063\"\u003eThe wood gasification boiler is for:\u003c\/p\u003e  \u003cul data-start=\"4065\" data-end=\"4254\"\u003e  \u003cli data-start=\"4065\" data-end=\"4105\"\u003e  \u003cp data-start=\"4067\" data-end=\"4105\"\u003eopen heating systems according to PN-EN 12828\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4106\" data-end=\"4158\"\u003e  \u003cp data-start=\"4108\" data-end=\"4158\"\u003eclosed systems with membrane expansion vessel\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4159\" data-end=\"4198\"\u003e  \u003cp data-start=\"4161\" data-end=\"4198\"\u003ethermal safety valve DBV-1\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4199\" data-end=\"4254\"\u003e  \u003cp data-start=\"4201\" data-end=\"4254\"\u003eReturn flow boost (e.g. 3- or 4-way mixing valve)\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"4256\" data-end=\"4346\"\u003eA return temperature of ≥ 55 °C is mandatory to prevent corrosion and tar formation.\u003c\/p\u003e  \u003chr data-start=\"4348\" data-end=\"4351\"\u003e  \u003ch1 data-start=\"4353\" data-end=\"4371\"\u003eTechnical data\u003c\/h1\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"4373\" data-end=\"5409\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"4373\" data-end=\"4391\"\u003e  \u003ctr data-start=\"4373\" data-end=\"4391\"\u003e  \u003cth data-start=\"4373\" data-end=\"4383\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"4383\" data-end=\"4391\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"4411\" data-end=\"5409\"\u003e  \u003ctr data-start=\"4411\" data-end=\"4453\"\u003e  \u003ctd data-start=\"4411\" data-end=\"4424\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"4424\" data-end=\"4453\" data-col-size=\"sm\"\u003eMPM Project Marcin Nykiel\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4454\" data-end=\"4479\"\u003e  \u003ctd data-start=\"4454\" data-end=\"4463\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"4463\" data-end=\"4479\" data-col-size=\"sm\"\u003eWood Plus 14\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4480\" data-end=\"4515\"\u003e  \u003ctd data-start=\"4480\" data-end=\"4493\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"4493\" data-end=\"4515\" data-col-size=\"sm\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4516\" data-end=\"4540\"\u003e  \u003ctd data-start=\"4516\" data-end=\"4531\" data-col-size=\"sm\"\u003eRated power\u003c\/td\u003e  \u003ctd data-start=\"4531\" data-end=\"4540\" data-col-size=\"sm\"\u003e14 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4541\" data-end=\"4578\"\u003e  \u003ctd data-start=\"4541\" data-end=\"4567\" data-col-size=\"sm\"\u003eGenerated useful heat (Pn)\u003c\/td\u003e  \u003ctd data-start=\"4567\" data-end=\"4578\" data-col-size=\"sm\"\u003e14.9 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4579\" data-end=\"4610\"\u003e  \u003ctd data-start=\"4579\" data-end=\"4604\" data-col-size=\"sm\"\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd data-start=\"4604\" data-end=\"4610\" data-col-size=\"sm\"\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4611\" data-end=\"4648\"\u003e  \u003ctd data-start=\"4611\" data-end=\"4641\" data-col-size=\"sm\"\u003eEnergy Efficiency Index (EEI)\u003c\/td\u003e  \u003ctd data-start=\"4641\" data-end=\"4648\" data-col-size=\"sm\"\u003e118\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4649\" data-end=\"4686\"\u003e  \u003ctd data-start=\"4649\" data-end=\"4678\" data-col-size=\"sm\"\u003eSeasonal energy efficiency\u003c\/td\u003e  \u003ctd data-start=\"4678\" data-end=\"4686\" data-col-size=\"sm\"\u003e81%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4687\" data-end=\"4733\"\u003e  \u003ctd data-start=\"4687\" data-end=\"4723\" data-col-size=\"sm\"\u003eefficiency at rated power\u003c\/td\u003e  \u003ctd data-start=\"4723\" data-end=\"4733\" data-col-size=\"sm\"\u003e83.7%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4734\" data-end=\"4769\"\u003e  \u003ctd data-start=\"4734\" data-end=\"4761\" data-col-size=\"sm\"\u003eThermal efficiency\u003c\/td\u003e  \u003ctd data-start=\"4761\" data-end=\"4769\" data-col-size=\"sm\"\u003e89%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4770\" data-end=\"4819\"\u003e  \u003ctd data-start=\"4770\" data-end=\"4785\" data-col-size=\"sm\"\u003eboiler class\u003c\/td\u003e  \u003ctd data-start=\"4785\" data-end=\"4819\" data-col-size=\"sm\"\u003eClass 5 (PN-EN 303-5:2021-09)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4820\" data-end=\"4843\"\u003e  \u003ctd data-start=\"4820\" data-end=\"4833\" data-col-size=\"sm\"\u003eheating surface\u003c\/td\u003e  \u003ctd data-start=\"4833\" data-end=\"4843\" data-col-size=\"sm\"\u003e2.0 m²\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4844\" data-end=\"4878\"\u003e  \u003ctd data-start=\"4844\" data-end=\"4864\" data-col-size=\"sm\"\u003eLoading chamber volume\u003c\/td\u003e  \u003ctd data-start=\"4864\" data-end=\"4878\" data-col-size=\"sm\"\u003eapprox. 52 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4879\" data-end=\"4917\"\u003e  \u003ctd data-start=\"4879\" data-end=\"4901\" data-col-size=\"sm\"\u003eFuel consumption\u003c\/td\u003e  \u003ctd data-start=\"4901\" data-end=\"4917\" data-col-size=\"sm\"\u003eapprox. 3.5 kg\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4918\" data-end=\"4942\"\u003e  \u003ctd data-start=\"4918\" data-end=\"4931\" data-col-size=\"sm\"\u003eBurning time\u003c\/td\u003e  \u003ctd data-start=\"4931\" data-end=\"4942\" data-col-size=\"sm\"\u003eapprox. 5 hours\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4943\" data-end=\"4977\"\u003e  \u003ctd data-start=\"4943\" data-end=\"4967\" data-col-size=\"sm\"\u003eWater quantity in the boiler\u003c\/td\u003e  \u003ctd data-start=\"4967\" data-end=\"4977\" data-col-size=\"sm\"\u003e74 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4978\" data-end=\"5010\"\u003e  \u003ctd data-start=\"4978\" data-end=\"4999\" data-col-size=\"sm\"\u003eMax. operating pressure\u003c\/td\u003e  \u003ctd data-start=\"4999\" data-end=\"5010\" data-col-size=\"sm\"\u003e1.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5011\" data-end=\"5044\"\u003e  \u003ctd data-start=\"5011\" data-end=\"5032\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e  \u003ctd data-start=\"5032\" data-end=\"5044\" data-col-size=\"sm\"\u003e60–90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5045\" data-end=\"5084\"\u003e  \u003ctd data-start=\"5045\" data-end=\"5075\" data-col-size=\"sm\"\u003eMinimum return temperature\u003c\/td\u003e  \u003ctd data-start=\"5075\" data-end=\"5084\" data-col-size=\"sm\"\u003e55 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5085\" data-end=\"5117\"\u003e  \u003ctd data-start=\"5085\" data-end=\"5103\" data-col-size=\"sm\"\u003eExhaust gas temperature\u003c\/td\u003e  \u003ctd data-start=\"5103\" data-end=\"5117\" data-col-size=\"sm\"\u003e125–140 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5118\" data-end=\"5148\"\u003e  \u003ctd data-start=\"5118\" data-end=\"5137\" data-col-size=\"sm\"\u003eExhaust gas mass flow\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5137\" data-end=\"5148\"\u003e9.1 g\/s\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5149\" data-end=\"5187\"\u003e  \u003ctd data-start=\"5149\" data-end=\"5176\" data-col-size=\"sm\"\u003eFlow\/return diameter\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5176\" data-end=\"5187\"\u003e38.1 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5188\" data-end=\"5206\"\u003e  \u003ctd data-start=\"5188\" data-end=\"5195\" data-col-size=\"sm\"\u003eHeight\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5195\" data-end=\"5206\"\u003e1100 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5207\" data-end=\"5234\"\u003e  \u003ctd data-start=\"5207\" data-end=\"5224\" data-col-size=\"sm\"\u003eWide cases\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5224\" data-end=\"5234\"\u003e480 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5235\" data-end=\"5260\"\u003e  \u003ctd data-start=\"5235\" data-end=\"5250\" data-col-size=\"sm\"\u003eTotal width\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5250\" data-end=\"5260\"\u003e585 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5261\" data-end=\"5286\"\u003e  \u003ctd data-start=\"5261\" data-end=\"5275\" data-col-size=\"sm\"\u003eTotal length\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5275\" data-end=\"5286\"\u003e1105 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5287\" data-end=\"5311\"\u003e  \u003ctd data-start=\"5287\" data-end=\"5297\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5297\" data-end=\"5311\"\u003eapprox.300 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5312\" data-end=\"5375\"\u003e  \u003ctd data-start=\"5312\" data-end=\"5345\" data-col-size=\"sm\"\u003eMinimum chimney cross-section\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5345\" data-end=\"5375\"\u003e180 x 180 mm or Ø 178 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5376\" data-end=\"5409\"\u003e  \u003ctd data-start=\"5376\" data-end=\"5402\" data-col-size=\"sm\"\u003eMinimum chimney height\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5402\" data-end=\"5409\"\u003e7 m\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"5411\" data-end=\"5414\"\u003e  \u003ch2 data-start=\"5416\" data-end=\"5431\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"5433\" data-end=\"5511\"\u003e  \u003cli data-start=\"5433\" data-end=\"5464\"\u003e  \u003cp data-start=\"5435\" data-end=\"5464\"\u003eMPM Wood Plus 14 boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5465\" data-end=\"5488\"\u003e  \u003cp data-start=\"5467\" data-end=\"5488\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5489\" data-end=\"5511\"\u003e  \u003cp data-start=\"5491\" data-end=\"5511\"\u003eWarranty documents\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"5513\" data-end=\"5516\"\u003e  \u003ch2 data-start=\"5518\" data-end=\"5557\"\u003eAccessories\/Recommendation (Cross-selling)\u003c\/h2\u003e  \u003cp data-start=\"5559\" data-end=\"5621\"\u003eFor compliant and long-lasting operation, we recommend:\u003c\/p\u003e  \u003cul data-start=\"5623\" data-end=\"5840\"\u003e  \u003cli data-start=\"5623\" data-end=\"5663\"\u003e  \u003cp data-start=\"5625\" data-end=\"5663\"\u003eBuffer tank 800 liters or larger\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5664\" data-end=\"5703\"\u003e  \u003cp data-start=\"5666\" data-end=\"5703\"\u003eThermal safety valve DBV-1\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5704\" data-end=\"5761\"\u003e  \u003cp data-start=\"5706\" data-end=\"5761\"\u003eReturn temperature boost (thermostatic mixing valve 55 °C)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5762\" data-end=\"5798\"\u003e  \u003cp data-start=\"5764\" data-end=\"5798\"\u003eDraft regulator for the chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5799\" data-end=\"5840\"\u003e  \u003cp data-start=\"5801\" data-end=\"5840\"\u003eAcid-resistant stainless steel chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5842\" data-end=\"5928\"\u003eSuitable buffer tanks and safety groups can be found at:\u003cbr data-start=\"5906\" data-end=\"5909\"\u003e\u003ca data-start=\"5909\" data-end=\"5928\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/gemashop.de\"\u003ehttps:\/\/gemashop.de\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-eri7ssmm.svg#304883\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e  \u003chr data-start=\"5930\" data-end=\"5933\"\u003e  \u003ch2 data-start=\"5935\" data-end=\"5968\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cul data-start=\"5970\" data-end=\"6250\"\u003e  \u003cli data-start=\"5970\" data-end=\"6034\"\u003e  \u003cp data-start=\"5972\" data-end=\"6034\"\u003eInstallation exclusively by a qualified specialist company\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"6035\" data-end=\"6092\"\u003e  \u003cp data-start=\"6037\" data-end=\"6092\"\u003eOnly use dry firewood (≤ 25% moisture)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"6093\" data-end=\"6132\"\u003e  \u003cp data-start=\"6095\" data-end=\"6132\"\u003eReturn temperature at least 55 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"6133\" data-end=\"6169\"\u003e  \u003cp data-start=\"6135\" data-end=\"6169\"\u003eNo operation without a buffer tank\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"6170\" data-end=\"6250\"\u003e  \u003cp data-start=\"6172\" data-end=\"6250\"\u003eNo burning of plastic, treated wood or liquid fuels\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"6252\" data-end=\"6311\"\u003eImproper operation will result in the loss of warranty.\u003c\/p\u003e  \u003chr data-start=\"6313\" data-end=\"6316\"\u003e  \u003ch2 data-start=\"6318\" data-end=\"6324\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"6326\" data-end=\"6453\"\u003e\u003cstrong data-start=\"6326\" data-end=\"6368\"\u003e1. Which fuels are permitted?\u003c\/strong\u003e\u003cbr data-start=\"6368\" data-end=\"6371\"\u003eFirewood with a residual moisture content of ≤ 25%. Other fuels are not permitted.\u003c\/p\u003e  \u003cp data-start=\"6455\" data-end=\"6588\"\u003e\u003cstrong data-start=\"6455\" data-end=\"6493\"\u003e2. Is a buffer storage tank mandatory?\u003c\/strong\u003e\u003cbr data-start=\"6493\" data-end=\"6496\"\u003eYes. Operation is only permitted with a buffer tank. According to the product data sheet, at least 800 liters.\u003c\/p\u003e  \u003cp data-start=\"6590\" data-end=\"6751\"\u003e\u003cstrong data-start=\"6590\" data-end=\"6660\"\u003e3. Can the boiler be operated in a closed system?\u003c\/strong\u003e\u003cbr data-start=\"6660\" data-end=\"6663\"\u003eYes, with a diaphragm expansion vessel, safety valve and thermal protection (e.g. DBV-1).\u003c\/p\u003e  \u003cp data-start=\"6753\" data-end=\"6833\"\u003e\u003cstrong data-start=\"6753\" data-end=\"6805\"\u003e4. What energy efficiency class does the boiler have?\u003c\/strong\u003e\u003cbr data-start=\"6805\" data-end=\"6808\"\u003eA+ with an EEI of 118.\u003c\/p\u003e  \u003cp data-start=\"6835\" data-end=\"6958\"\u003e\u003cstrong data-start=\"6835\" data-end=\"6893\"\u003e5. What is the minimum return temperature required?\u003c\/strong\u003e\u003cbr data-start=\"6893\" data-end=\"6896\"\u003eAt least 55 °C to prevent corrosion and tar formation.\u003c\/p\u003e  \u003cp data-start=\"6960\" data-end=\"7106\"\u003e\u003cstrong data-start=\"6960\" data-end=\"7006\"\u003e6. What are the chimney requirements?\u003c\/strong\u003e\u003cbr data-start=\"7006\" data-end=\"7009\"\u003eMinimum cross-section 180 x 180 mm or Ø 178 mm, minimum height 7 m, required tension approx. 0.20 mbar.\u003c\/p\u003e  \u003chr data-start=\"7108\" data-end=\"7111\"\u003e  \u003ch2 data-start=\"7113\" data-end=\"7121\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"7123\" data-end=\"7384\"\u003eThe MPM Wood Plus 14 wood gasification boiler is a technically sophisticated solution for efficient heating with logs. With Class 5, Ecodesign compliance, and an A+ energy rating, it offers a sustainable and high-performance heating solution for modern heating systems with buffer storage.\u003c\/p\u003e  \u003cp data-start=\"7386\" data-end=\"7447\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eOrder now and modernize your heating technology efficiently.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":56653812859228,"sku":"MPMWP14","price":2350.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-wood-plus-14-kw-holzvergaserkessel-a-klasse-5-o178-holzvergaserkessel-5655773.webp?v=1770944058"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/collections\/holzvergaser-bis-20-kw-9263260.webp?v=1770692166","url":"https:\/\/nl.gemashop.de\/en\/collections\/bis-20-kw-1.oembed","provider":"GEMA Shop","version":"1.0","type":"link"}